    SERIES 400 AND 400-P GAS CHROMATOGRAPHS

    SERIES 400 AND 400-P GAS CHROMATOGRAPHS

    The GOW-MAC Series 400 and 400-P Isothermal, Thermal Conductivity Detector (TCD) Gas Chromatographs are rugged, compact, affordable, service-free GCs designed for high capability performance while withstanding rough, student or industrial use. They meet the demands for teaching the principles of gas chromatography, chemistry and biochemistry. As of January of 2005, the Series 400 GCs has replaced our very popular Series 350 GCs. Isothermal Operation Detector: Thermal Conductivity Detector (TCD) Direct On-Column Injection or Gas Sample Valve (manual or pneumatic) Single or Dual Column Microscale Compatible: heated, threaded exit ports (optional) Accommodates 1/8” or ¼” o.d. metal or 6 mm glass columns Signal Amplifier, x10 (optional) Independent, Direct Set, Temperature Controls for Column Oven, Detector, Injection Ports Operating temperature: ambient to 300 °C Power: 110-220 V, 50-60 Hz >>>
    View the product on gow-mac.com GOW-MAC«
    ALLTIMA™ HP HILIC COLUMN

    ALLTIMA™ HP HILIC COLUMN

    Hydrophilic Interaction (HILIC) Columns for highly polar basic analytes Superior retention of highly polar compounds Increased sensitivity and lower detection limits with LC/MS Hydrophilic Interaction Chromatography is ideal for separating and retaining very polar compounds that may not retain on traditional reversed phase packings. Unlike reversed phase columns, HILIC columns retain highly polar compounds with only small amounts of water in the mobile phase. These more volatile mobile phases increase sensitivity with LC/MS applications >>>
    View the product on discoverysciences.com Grace Davison Discovery Sciences
    PARTIAL DISCHARGE MONITORING - INDIPARD® IDP 16

    PARTIAL DISCHARGE MONITORING - INDIPARD® IDP 16

    Evaluation Unit for Online Partial Discharge Monitoring Brief description Online monitoring, surveillance and diagnosis of partial discharges Alerting in the case of limit violation Event-driven maintenance Can be retrofitted on old installations Search coils for coupling without physical contact Sensors with CapEye® interface connectable Can be expanded for up to eight monitoring points Designed as an operational measuring instrument and for constant duty Compact design and practically orientated installation system Adjustable limits and interference suppression per input Self monitoring and alerting in the event of device failure Can be configured by user on PC Optional: Data transfer via fixed-network or GSM modem Measured value acquisition with PC >>>
    View the product on may-elektronik.de May Elektronik
    DAVISIL® CHROMATOGRAPHIC SILICA MEDIA

    DAVISIL® CHROMATOGRAPHIC SILICA MEDIA

    Recognized worldwide as media of high purity, DAVISIL® silica's are the cornerstone of Grace's matrix of selective chromatography products. Consisting of granular shaped particles with excellent mechanical and structural properties, DAVISIL silicas are versatile, consistent and reliable. They are ideal for small columns, HPLC, solid phase extraction, flash chromatography, and scale-up to industrial process applications. DAVISIL silicas are available in particle sizes from 6 µm to 3,000 µm and pore sizes from 30 Å to 2,500 Å. A variety of well-defined standard grades are available as indicated in the tables below. Please contact your Grace representative for consultation and quotation regarding specific requirements. >>>
    View the product on alltechweb.com Alltech Associates Applied Science Ltd
    NEW SUPER FAST PERFORMANCE - WAVEQUEST

    NEW SUPER FAST PERFORMANCE - WAVEQUEST

    WaveQuest the CE4300 Dynamic Absorbance Detector (DAD) is an ultra high speed scanning powerful alternative to Photo Diode Array detectors. HPLC method development, purity determination, R & D and Variable Wavelength Monitoring are all possible with the highest quality. Dual wavelength monitoring and wavelength programming are also provided. The design is based on a double beam spectro-photometer concept with ultra fast wavelength scanning over the range 190-700nm. This dynamic scan provides UV spectra in only 200mS, previously only possible using the static optical system of a PDA detector. Powerful signal processing software has been developed which enables very high quality “on-the-fly” scans to be triggered by eluting peaks without the peaks being degraded. Spectral data is transferred by Cecil’s DataStream software to a PC workstation where the same software offers spectral manipulation and processing, library facilities and the export of data to applications such as Excel, word etc. All data may be stored on disk. Eluting peaks may be integrated at the same time as purity and peak identification is carried out. Quantitative evaluation and reporting is carried out by Cecil’s CE4900 PowerStream software, which is combined with DataStream software. >>>
    View the product on cecilinstruments.net Cecil Instruments
    ANALYTICAL NOVOGROM COLUMNS

    ANALYTICAL NOVOGROM COLUMNS

    ANALYTICAL NovoGROM COLUMNS – 3.0, 4.0, and 4.6 mm i.d. The analytical NovoGROM HPLC column system is many-fold proven. These columns can be connected to any HPLC system either conventionally via 1/16" capillary, ferrules and screw fittings or dead volume free via the NovoGROM Quick connectors. Standard dimensions are 3, 4 and 4.6 mm internal diameter and lengths of 2, 4, 6, 10, 12.5, 15, 20, 25 and 30 cm. Guard columns, i.e., protective precolumns, are available in the lengths of 5, 10 and 20 mm. Columns may be filled as often as is required in the economical refill service. Use of the 3 mm i.d. column results in a reduction in the consumption of solvent of ca. 43% or 57% compared to the 4 mm and 4.6 mm i.d. columns respectively. This not only reduces costs, but is also active environmental protection. All NovoGROM columns can be supplied with any of the stationary phases listed on GROM websites or in this GROMHPLC catalogue (see pages 12/13 and 144-151). Alternatively, they may also be packed by the GROM filling service with any stationary phase specified by the customer. >>>
    View the product on grom.de Grom Chromatography Groupe - Grace
    BROADBAND METER

    BROADBAND METER

    The perfect solution for the monitoring / measurement of RF pollution. The Broadband meter was designed as a general purpose electromagnetic measurement tool. It detects electric and magnetic fields from power line frequencies up to several GHz. It is unique in its combination of a magnetic AC gaussmeter, electric field meter and RF field strength meter, all in one small package. Therefore it can be used to study and measure the magnetic fields produced by electrical power cables (including overhead lines), the fields produced by video displays, right through to the radiation emitted by microwave ovens, mobile phones and wireless LANs. Other applications include the measurement of RF environments to minimise health risks, detection of leakage from microwave ovens and detection of concealed transmitters. Specifications Gauss Meter: 0-3 range: 0.2 - 3 milligauss. 0-100 range: 0.3 - 100 milligauss. Freq. range: 50 - 500Hz flat. Accuracy: ±20 % to 50MHz Electric field: Range: 10 V/m - 100 KV/m Freq. range: 40 - 100KHz. Accuracy: ±25 % RF Field Strength: Range: 0.01 - 1 KV/m Freq. Range: 100KHz - 2.5 GHz flat. Indication: Analogue meter with rotary range change switch. Power: 9V (PP3) internal Battery. Battery test reading on meter. Size: 15 cm x 9 cm x 3 cm >>>
    View the product on laplace.co.uk Laplace Instruments Ltd
    GPC AUTOSAMPLERTM

    GPC AUTOSAMPLERTM

    The Viscotek GPC Autosampler is specifically designed for GPC using a fixed volume sample loop for excellent reproducibility. The easy programming and variable wash programs combined with a large vial capacity give the autosampler maximum flexibility. Options are available for variable volume injection programming, temperature control and large vials for semi-preparative work. Key Features include: Excellent reproducibility - the autosample overfills a fixed volume loop Easy programming through the interactive screen Chemically resistant to a wide range of GPC eluents Flexible wash programming to minimize carry-over Optional variable volume injection loop programming Two removable vial tracks, each with 60 positions Heating/Cooling option available Technical Specifications Sample loop: 100 ul; Options: 20–400 ul Reproducibility: Better than 0.5% at 100 ul Carry-over: < 0.01% Needle cleaning: Programmable Number of vials: 2 racks x 60, 2 ml each Standard vials: 2 ml clear glass, screw caps; Options: Variable injection volume, Temperature control 4–70C Power: 230/110 V, 50/60 Hz >>>
    View the product on viscotek.com Viscotek Europe
    LACHROM ELITE

    LACHROM ELITE

    A masterpiece of modern technology The new generation LaChrom Elite® system from VWR-Hitachi is a robust, versatile and well designed HPLC instrument line with excellent precision and sensitivity as well as minimum sample carry-over. Designed for ease of use, all operational and maintenance parts are accessible from the front. Together with the comprehensive and FDA compliant chromatography data system EZChrom Elite® offers a high degree of capability in data processing and chromatography systemcontrol(1). >>>
    View the product on uk.vwr.com VWR
    842 SULFUR GAS CHROMATOGRAPH

    842 SULFUR GAS CHROMATOGRAPH

    Sulfur Chemiluminescence Technology Galvanic Applied Sciences Inc. manufactures a complete line of state of the art analyzers for lab and process applications which employ sulfur chemiluminescence technology to detect sulfur in a wide variety of hydrocarbon samples. Some chemiluminescence applications: Pipeline natural gas and odorization systems LPG and LNG products Refinery and plant fuel gas Ethylene and propylene >>>
    View the product on galvanic.com Galvanic
    COLUMN HPLC - WYATT COMET™

    COLUMN HPLC - WYATT COMET™

    Wyatt COMET™ (Cell Operation and Maintenance Enhancing Technology)Light scattering is the premier technique for absolute macromolecular characterization. However, it is well known that in order to achieve the most accurate and reproducible results, one must maintain scrupulously clean optics and mobile phase. Even when the mobile phase is pre-filtered, chromatography columns continuously shed small particles that, over time, can contaminate even the cleanest optics. This is where the Wyatt COMET™ (Cell Operation and Maintenance Enhancing Technology) concept becomes indispensable. This new device may be integrated with the flow cell manifold of a DAWN DSP, DAWN EOS, miniDAWN or miniDAWN Tristar and applies a radio frequency ultrasonic field specially tuned to the flow cell structure itself. Unlike traditional ultrasonic cleaning methods, the field produced by the COMET device is resonant with the flow cell bore and does not produce cavitation bubbles that might damage the glass surface-nor does it form bubbles that would affect the scattering signals themselves. When used on a regular basis, the need to remove the flow cell for cleaning may be postponed indefinitely. The COMET loosens particles that may have adhered to the cell walls and removes them on a daily basis. In addition, the periodic activation of the device can prevent the adhesion of new particles. Moreover, the device operates in-situ while the mobile phase is flowing through the cell. There is no need to disconnect any fluid fittings, change solvents, or disassemble anything. Wyatt Technology's Chief Executive Officer, Dr. Philip Wyatt noted that successful light scattering measurements come from minimizing dust and flare from the laser beam. "Up until now, our patented flow cell design has addressed these problems in three ways. First, the critical entrance and exit windows of the flow cell are located far from the scattering center to reduce the effect of contaminated windows. Second, the laser light source is focused into an extremely small beam diameter so that particulates and other contaminants on the walls are not illuminated. Third, the flow cell can be easily removed, manually cleaned, and reinstalled without perturbing the optical alignment. What has always been required, however, is an on-line method of maintaining flow cell cleanliness. That's what is so exciting about this novel device." >>>
    View the product on wyatt-europe.com Wyatt Technology Europe
    DOCUMENTATION PACKAGES - IQ/OQ

    DOCUMENTATION PACKAGES - IQ/OQ

    The Faster Way to Validation ! Our IQ/OQ validation procedures (disk and hardcopy) mark YSI Life Sciences's entry into validation services for our markets. Installation qualification (IQ) and operational qualification (OQ) are processes which manufacturers of FDA-regulated products must validate with each instrument that is integrated into a manufacturing system. The availability of IQ/OQ documentation directly from the instrument's manufacturer can save you precious time and resources. >>>
    View the product on ysi.com/lifesciences.htm YSI Life Science Groupe - YSI
    RF POWER SYSTEMS VARIOMATCH AUTOMATIC MATCHING NETWORKS

    RF POWER SYSTEMS VARIOMATCH AUTOMATIC MATCHING NETWORKS

    High tuning accuracy and speed enable VarioMatch™ automatic matching networks to deliver extremely consistent power across a wide range of plasma load conditions (600 W to 5 kW, 2 to 40.68 MHz). Optimized for capacitively coupled plasma and CO2-laser loads, these highly reliable devices increase yield and productivity. VarioMatch networks are easy to operate and integrate with any existing system. Their compact, plug-and-play design eliminates the need for external controllers and enables easy mounting close to the chamber. Although they are compatible with any RF generator, VarioMatch networks offer unique benefits when combined with Advanced Energy® Cesar® RF power supplies. >>>
    View the product on advanced-energy.com Advanced Energy Industries UK Ltd
    DICHROIC FILTERS

    DICHROIC FILTERS

    Dichroic filters (color separation filters) are used in a variety of applications where it is necessary to isolate certain regions of the visible spectrum. A few of the more common applications are for use in color enlargers and photocopiers as light balancing filters. They are also very useful in any application where it may be desirable to separate the incident energy into two or more light beams. The following spectral curves are displayed at normal incidence, but for many applications, such as combining colors, it may be desirable to use them in the reflecting mode at a 45° angle of incidence. >>>
    View the product on lot-oriel.com LOT-Oriel Ltd
    CHROMATOGRAPHY  PETROPRO

    CHROMATOGRAPHY PETROPRO

    High Speed Chromatography Made Simple PetroPRO can analyze benzene in less than 2 minutes or BTEX in less than seven minutes down to low PPB levels. PetroPRO utilizes photoionization detector which reports sample concentrations from low PPB up to hundreds of PPM. Two analytical models of PetroPRO available: Fenceline for perimeter, occupational exposure, and other general measuring requirements Canister for measuring benzene in the presence of complex and highly concentrated VOC streams. >>>
    View the product on photovac.com Photovac
    SERIES 580 RESEARCH GAS CHROMATOGRAPH

    SERIES 580 RESEARCH GAS CHROMATOGRAPH

    The Series 580 Gas Chromatograph sets the standard for reliable performance in a wide range of applications. So impressive has the performance of this GC been, that many 580 users refer to it as "The Workhorse" instrument of their laboratory. The Series 580 GC can be customized to fit the exact requirements your application requires, utilizing either a TCD, FID, DID or PID detector. Isothermal Operation Detectors: TCD, FID, DID, or PID Direct On-Column Injection or Gas Sample Valve: packed, capillary — split/splitless Single or Dual Column Accommodates 1/8” or 1/4” o.d. metal, 6 mm glass, or capillary columns Column temperature range: ambient to 400 °C Column oven temperature protection circuit Readout: 3-1/2 digit LED digital display Independent Temperature Controls for Column Oven, Detector, Injection Ports On-line monitoring and valve manipulation by software or linking workstation Microscale Compatible: heated, threaded exit ports, (optional — TCD only) Signal Amplifier, x10 (TCD — optional) Choice of standard or corrosion resistant system Installation: bench or 19” rack mount Power: 110-220 V, 50-60 Hz >>>
    View the product on gow-mac.com GOW-MAC«
    AXIAL SFC COLUMN HARDWARE

    AXIAL SFC COLUMN HARDWARE

    For Use with MULTIPACKER™ Packing Instruments Grace Axial SFC Columns are design-related to SPRING COLUMN™ axial compression columns. They are packed with the same, easy-to-use MULTIPACKER™ packing systems but are designed with the requirements of supercritical fluid chromatography in mind. Custom seals, suitable for use with supercritical CO2 at pressures up to 5000 psi, are manufactured specially for Grace Vydac. The axial compression packing mode is still employed. However, the internal spring axial compression has been omitted because of the high pressures typical in SFC systems and the low visosity of the mobile phase, which makes void fromation less likely. >>>
    View the product on discoverysciences.com Grace Davison Discovery Sciences
    PARTIAL DISCHARGE MONITORING - INDIPARD® IDPS

    PARTIAL DISCHARGE MONITORING - INDIPARD® IDPS

    Sensors for Online Partial Discharge Monitoring Brief description Active partial discharge sensors Integrated preamplifier Search coil for coupling without physical contact Inductive coupling for monitoring individual components 3-phase CapEye® amplifier for capacitive coupling electrodes Can be retrofitted in old installations Compact design and practically orientated assembly system Powered and monitored by Indipard evaluation unit Field of application and benefits The partial discharge (PD) sensors, together with the INDIPARD evaluation unit, form an online monitoring system for insulation monitoring of high-voltage and medium-voltage installations. Continuous monitoring of partial discharge activities offers the opportunity of detecting a worsening or serious change in the condition of the insulation of the equipment at an early point, thus giving the user the opportunity to intervene in good time so as to prevent more serious damage. Mode of operation The PD sensors are installed in the parts of a medium-voltage or high-voltage installation at risk. They detect the highfrequency electric fields generated by the partial discharges and forward them to the IDP16 via coaxial cable. The sensors are active, i.e. they feature a preamplifier. It is powered by the evaluation unit via the coaxial cable. Depending on application, either search coils, inductive PD sensors, capacitive coupling electrodes with a CapEye® amplifier or devices with CapEye® interface may be used. Search coil The search coil performs coupling without physical contact. It must be fitted in the electric field between high voltage and earth. Its metal bar forms a capacitive coupling electrode. Its range is approx. 2 m in open installations and approx. 1 m in enclosed installations. It is particularly suitable for retrofitting in old installations. Complete installation kits are available for specific types of installation. Inductive PD sensor The high-frequency current generated by partial discharges is detected with respect to earth with the aid of a Rogowski coil. Such a coil is suitable for monitoring individual components such as a transformer.. In this case, it must be ensured that the section to be monitored features only one defined earthable point and is otherwise installed on insulated mountings. CapEye® amplifier The CapEye® amplifier features three inputs for connection to capacitive coupling electrodes such as capacitive insulators or capacitive coupling electrodes. The range is approx. 5 m from the installation location in both directions of the conductor but ends after approx. 1 m in cable. CapEye® amplifiers have improved common mode rejection cabability. The CapEye® amplifier is particularly suitable for monitoring twin switchgear cells, in the case of multi-tier design or in the case of multiple separation of switchgear cells. Voltage test system with CapEye® amplifier The Capdis-Sx-C is an integrated, capacitive voltage test system in accordance with IEC 61243-5, either with or without contact outputs. It is also fitted with a CapEye® amplifier and thus allows monitoring of the voltage and condition of the insulation on the same coupling electrodes. Technical data Connection cable to evaluation unit Type Coaxial cable Length up to 50 m per input Search coil IDPS-A-F Rated meas. range 400 pC Antenna bar length standard 50 cm, min. 30 cm, max. 200 cm Installation with 2 spacers directly on an earthed surface within the switchgear cubicle Min. earthing clearance 2 cm Opt. earthing clearance 4 ... 10 cm Detection range with 4 cm earthing clearance min. 100 cm in enclosed installations min. 200 cm in open installations Perm. amb. temp -20° ... 55°C in operation -30° ... 70°C for storage Connection F socket and earth >>>
    View the product on may-elektronik.de May Elektronik
    GRACERESOLVTM FLASH CARTRIDGES

    GRACERESOLVTM FLASH CARTRIDGES

    High Resolution Increased Loading Capacity Reproducible Performance Two Cartridge Styles Superior Silica Grace’s 30 years of chromatography experience combined with 80 years of silica manufacturing expertise has yielded the ideal flash cartridge, GraceResolvTM flash cartridges. GraceResolvTM cartridges are packed with a new grade of Davisil® silica designed to maximize performance of today’s flash instruments. >>>
    View the product on alltechweb.com Alltech Associates Applied Science Ltd
    SMOOTH VERSATILE AND EFFORTLESS ION CHROMATOGRAPHY

    SMOOTH VERSATILE AND EFFORTLESS ION CHROMATOGRAPHY

    Flat, Stable Baselines coupled with High Sensitivities The use of the newly upgraded CE 4710 Conductivity Detector, coupled with the continuously regenerated chemical carbonate suppressor columns will provide for flat baselines, high sensitivities, gradient usage and speedy column equilibration. Whatever your Ion Chromatography requirements, IonQuest will provide great value plus more. Versatile One single system will accommodate your requirements for now and the future. There is no limitation on the choice of eluents, columns, pumps, sample pre-treatment, samples and column conditions. Adherence to EPA methods is easily achieved. A vast range of analytical columns can be supplied. Exceptionally ultra-low drift The use of high stability temperature control of the detector cell contributes towards the extremely low drift. Peace of mind will be your norm. The drift of the conductivity detector is so low, that overnight unattended runs are easily achieved when the detector is used with any of our reliable autosamplers. High pressure mixing gradients Using the pulse-free microprocessor controlled pumps, achieve precise control and repeatability of mobile phase mixtures, to 0.1% levels. Coupled with rapid responses to changes in concentration and lower incidences of bubbling of the mixed mobile phase, the achieved gradients are the best. A large range of pumping volumes, with low volume pumping increments is available. Hence method development is achieved with fewer set-backs and the developed methods are more transferable. Additional Detector Options In addition to the standard conductivity detector, the IonQuest can be used with other detectors, such as electrochemical, refractive index, UV/Visible, WaveQuest UV/Visible ultra-fast scanning and fluorescence. Your options will not be limited. Analyse catecholamines in blood plasma with an electrochemical detector, whilst simultaneously analysing anions using a conductivity detector. Detect all the organic acids in wine using the conductivity detector, whist simultaneously detecting the sugars with refractive index or electrochemical detectors. Amino acids, metals in soil, nucleic acids, fluoride and sodium in toothpaste, sodium in foods, bromide in water. >>>
    View the product on cecilinstruments.net Cecil Instruments
    CAPILLARY COLUMNS

    CAPILLARY COLUMNS

    In addition to the on-line coupling with a mass spectrometer, the driving force behind the continuous development of microbore- and capillary chromatography has come in particular from the fields of physiological chemistry and neurochemistry, where the volumes of sample available are often extremely low (µl or even nl), thus requiring maximum sensitivity. Both the reduced running costs and the environmental benefits arising from the drastically reduced consumption of solvents are further significant advantages gained by the miniaturisation of HPLC. GROM offers a full range of columns and accessories for capillary HPLC for those interested in taking advantage of the most modern developments in HPLC. Similar to the proven analytical NovoGROM cartridge system, the integrated guard columns are sealed manually without tools („finger-tight“). According to the customer‘s requirements these columns can be supplied packed with any stationary phase listed in this catalogue. >>>
    View the product on grom.de Grom Chromatography Groupe - Grace
    MICROALERT

    MICROALERT

    sensitive RF detector (-S) or an alarm to warn of hazardous RF radiation (-P) Radio / microwave alarm is the size of a small pager, just 5.7cm x 4cm x 2cm. The high sensitivity version is ideal for anyone who needs to find out exactly what is emitting radio or microwaves, including hidden sources. An industrial version is triggered by higher levels of radiation and is ideal for personnel alarm use when working near transmitters or RF sources. The alarm provides an audio output that bleeps when the pre-set level is reached, the frequency of the bleeps increases if the signal level increases. The sensitive version will detect a typical mobile phone base station from 100 metres, a mobile phone at 6 metres and a microwave oven at 3 -10 metres. The sensitivity can be adjusted to suit the application with a small adjustment knob. >>>
    View the product on laplace.co.uk Laplace Instruments Ltd
    GPC DEGASSERTM

    GPC DEGASSERTM

    The Viscotek membrane Degasser works in-line, degassing eluent for optimal pump performance and improved detector baselines. The multi-channel membrane degasser is chemically resistant to a wide range of GPC eluents and has 2, 3 or 4 channels, each of which can be used for a different eluent. Key Features include: Efficient in-line degassing improves pump performance Reduced baseline noise, especially for Light Scattering and Viscometer detectors Chemically resistant to a wide range of GPC eluents Recommended for use with triple detection Technical Specifications Flow rate: maximum 10 ml/min Efficiency: 0.5 ppm oxygen at 0.5 ml/min Channel volume: 8 ml/channel Materials: PTFE, PEEK in contact with solvent Vacuum: < 850 mbar Display: LCD Power: 230/110 V, 50/60 Hz >>>
    View the product on viscotek.com Viscotek Europe
    LACHROMULTRA™ SYSTEM

    LACHROMULTRA™ SYSTEM

    The High-Speed HPLC System • Ultra-fast chromatography • Superior resolution • Unique flexibility • Enhanced reliability • A quantum leap in productivity The LaChromUltra™ system from VWR-Hitachi is a very versatile high-performance HPLC showing excellent precision and sensitivity and with minimal sample carryover. It has been optimized for high-speed chromatography with both particulate and monolithic columns and is equipped with a number of special functions. At the same time it is excellently suited to all standard HPLC applications. The LaChromUltra™ system is very user-friendly as all parts relevant to operation and maintenance are accessible from the front. Together with the comprehensive and FDA-compliant chromatography data system EZChrom Elite® it offers a high degree of capability in data processing and chromatography system control. >>>
    View the product on uk.vwr.com VWR
    WYATTQELS (QUASI-ELASTIC-LIGHT-SCATTERING) INSTRUMENT

    WYATTQELS (QUASI-ELASTIC-LIGHT-SCATTERING) INSTRUMENT

    WyattQELS™ On-Line Quasi Elastic Light Scattering from your HPLCThe WyattQELS (Quasi-Elastic-Light-Scattering) instrument contains a real time digital correlator. The correlator measures the autocorrelation function of the intensity signal from any one angle of the DAWN or from the 90 degree location of the miniDAWN. The correlator then calculates the hydrodynamic radius at each elution time in order to provide hydrodynamic radii over an entire chromatographic peak. Unlike many other dynamic light scattering instruments, the WyattQELS detector, when interfaced to the DAWN, allows one to measure correlation as a function of angle. Particles larger than 150nm may scatter relatively little light at 90 degrees because of intra-particle interface or "Mie scattering". This effect may cause significant distortion in computer particles size distribution for some kinds of polydisperse samples. Since the WyattQELS optical fiber can be moved easily to any one of the 18 DAWN angles, the measurements can be optimized for the best results for particles that are very large. With most other instruments, which only make measurements at 90 degrees, if large particles are present, the signals may be low or lost altogether. But with the WyattQELS you can always move the optical fiber to a lower or a higher angle. WyattQELS Features include: Multiple Tau correlation design with a fixed range of channel from 480 nsec to ~1 hour (real-time). No sample time optimization required! A total of 264 channels with input data format of 5 bit for the first 16 channels, the the sample time doubles every 8 channels and the data width is incremented 1 bit for every set of channels. No pre-scaling required. >>>
    View the product on wyatt-europe.com Wyatt Technology Europe
    SERIES 590 HIGH PURITY GAS ANALYSIS GAS CHROMATOGRAPH

    SERIES 590 HIGH PURITY GAS ANALYSIS GAS CHROMATOGRAPH

    The Series 590 GC features our patented Discharge Ionization Detector (DID) which permits analysis of trace gas impurities in the part per billion (ppb) range. Manufacturers of UHP specialty, electronic and bulk industrial gases are successfully using the Series 590 DID GC to analyze gases for ppb level of contamination. Each Series 590 GC is custom built to a particular application. Contact us to discuss the details or your specific requirements. Discharge Ionization Detector (DID) — non-selective, non-radioactive, universal and concentration dependent Detector sensitivity: < 10 ppb CH4 Detector linearity: > 105 Dynamic range of < 5 ppb to < 1% by volume High analytical precision: ± 1% full scale Output: 4-20 mA (optional); 0-1 mV Helium purged housing eliminates system contamination and increases system sensitivity Bellows type metering valves for independent flow control of column carrier gases and detector discharge gas Choice of standard or corrosion resistant system Installation: bench or 19” rack mount On-line monitoring and valve manipulation by software or linking workstation Power: 120-240 V, 50-60 Hz >>>
    View the product on gow-mac.com GOW-MAC«
    GRACESMARTTM HPLC COLUMN

    GRACESMARTTM HPLC COLUMN

    Smart Quality Smart Performance Smart Value Grace Davison Discovery Sciences sets a new standard in HPLC columns. From the silica particle to the finished product, our streamlined manufacturing delivers smart quality and smart performance, at an exceptional value. GraceSmart™ HPLC Phases use high purity silica and are monomerically bonded with uniform coverage. This translates into symmetrical peaks for acids/bases, and predictable reversed phase selectivity. GraceSmart™ columns show similar or better efficiency and asymmetries for challenging base and acid components in comparison to industry leading columns. >>>
    View the product on discoverysciences.com Grace Davison Discovery Sciences
    PORTABLE PARTIAL DISCHARGE TESTER - INDIPORT IDC 20

    PORTABLE PARTIAL DISCHARGE TESTER - INDIPORT IDC 20

    Portable partial discharge tester for switchgear Brief description Partial discharge tests in a few minutes without having to shutdown Checkable and reproducible due to artificial PD source Specially designed for medium-voltage switchgear Utilises the coupling capacitance of the voltage testing system Fits directly to HR interfaces or equipment and sensors with CapEye®-Interface Read off and/or record measured values Long-term observations, trend recognition Data recorded on SD memory cards Evaluation on a PC with standard software Light, portable and maintenance-free Can be used without a PC Optional: sensors to record weather data simultaneously: pressure, temperature, humidity and dew point Optional: sending text messages via GSM modem Area of application The use of partial discharge (PD) tests on high-and medium-voltage installations is now undisputed. Manufacturers test their equipment before delivering it to customers. Many customers ask for a repeat test after assembly and before commissioning on site. However, these do not include the major weak points for operators, namely the cable terminations. Subsequent regular testing requires the complete isolation of the installation, is very costly and is therefore generally dispensed with. INDIPORT is a portable partial-discharge measuring system. It is designed for use during operation and does not need the installation to be isolated. Installations can consequently be tested at any time and at reasonable cost. In addition to instantaneous values, the INDIPORT can also be used for long-term measurements, including climate measurements. Method of operation INDIPORT, with its preamplifier, uses the existing capacitance taps on the switchgear, such as the HR interfaces or voltage testing systems with CapEye® interface. Sensors in the INDIPARD partial discharge monitoring system can also be connected directly. The normal operating voltage is used as the test voltage. Pulses with a known charge are fed in from the adjacent cell with the IDP-SRC PD simulator, again via the capacitance tap, and compared with the display. This means the measurement results are reproducible and comparable with other stations. Partial discharges often occur sporadically, depending on the weather. In order to be able to obtain any meaningful information about the condition of the insulation in an installation, observation over an extended period of time is necessary. Consequently, the INDIPORT includes a complete data logger for long-term data capture in addition to the momentary display with a phase diagram. SD or SDHC memory cards of up to 32 GB storage capacity can be used for data recording. PD measurements from different time periods and locations can only be compared if the most important climate data is taken into account. To do this, INDIPORT simultaneously captures the partial discharge activity, relative humidity, temperature, dew point and air pressure at adjustable time intervals. For evaluation, the memory card is removed from the unit and can then be evaluated on a PC with a card reader and spreadsheet program. INDIPORT can be combined with a GSM modem. When a PD occurs, the unit calls the service personnel by text message. This is particularly important when searching for and localising sporadic PDs. INDIPORT is supplied with its accessories in a study plastic carrying case. >>>
    View the product on may-elektronik.de May Elektronik
    PLATINUM™ COLUMNS

    PLATINUM™ COLUMNS

    Dual-selectivity for challenging separations More separation choices with dual-selectivity Better peak shapes with polar analytes Excellent stability and reproducibility Platinum™ phases have hydrophobic and polar selectivity to separate mixtures that a strongly hydrophobic phase cannot. With Platinum™, it is easier to elute hydrophobic compounds and you can choose polar interactions as an alternate separation mechanism. Use Platinum™ EPS (Extended Polar Selectivity) for highly polar compounds. >>>
    View the product on alltechweb.com Alltech Associates Applied Science Ltd
    SUPERB PERFORMANCE HPLC - ADEPT SERIES

    SUPERB PERFORMANCE HPLC - ADEPT SERIES

    Adept Series HPLC systems and modules offer top grade performance, are economically priced and designed for all applications including method development, quality assurance, quality control, pharmaceutical and ion chromatography. A revolutionary new UV-Visible Dynamic Absorbance Detector (DAD), offers all the spectral capabilities of a Photo-Diode Array Detector (PDA), with greatly improved performance when used as a variable wavelength detector (VWD). Pumps, UV detectors and system control modules may be stacked vertically for the smallest possible space requirement or in lower profile where space permits. State of the art design, based on 30 years of HPLC design experience, is combined with up to the minute software, designed to operate in Windows XP, but may also be used with Windows 98 and 2000. It offers the easiest possible use with full system control, spectral and data processing. Ultra Fast Scanning Detector Cecil Instruments introduce WaveQuest, a breakthrough in UV-Visible detector design. A true alternative to Photo Diode Array detectors. Super fast wavelength scanning, scanning UV spectrum in 200 ms. Powerful spectral processing software for R&D, method development, purity determination etc. Absolutely top performance as variable wavelength detector, with data processing by PowerStream software, another Cecil Instruments development. >>>
    View the product on cecilinstruments.net Cecil Instruments
    MICROBORE COLUMNS

    MICROBORE COLUMNS

    NovoGROM Microbore Columns – 1 and 2 mm i.d. – Many of the modern biochemical applications requiring micro-column HPLC may be conveniently solved by the employment of NovoGROM microbore columns. With 2 or 1 mm i.d. columns, a 4-fold or 16-fold increase in sensitivity, respectively, is obtained relative to conventional 4 mm i.d. columns. At the same time, the solvent consumption at constant linear flow-rate decreases by 75% or 93% respectively. The requirements for microbore HPLC (in particular constant flow at low volumetric flow-rates) are fulfilled by all modern HPLC systems, so that customers can take advantage of this modern form of HPLC simply by the use of NovoGROM microbore columns. According to customers requirements, NovoGROM microbore columns can be supplied packed with any of the stationary phases described in this catalogue, or can be packed by the GROM column-filling-service with any other (eg., customer‘s own) stationary phase. >>>
    View the product on grom.de Grom Chromatography Groupe - Grace
    RF1000/RF2000 SYNTHESISER

    RF1000/RF2000 SYNTHESISER

    RF1000 Synthesiser (30MHz - 1GHz) RF2000 Synthesiser (30MHz - 2.4 GHz) PC controlled RF synthesisers for immunity testing up to 2.4GHz matched to the requirements of IEC61000-4-3 and featuring automatic scanning to pre-programmed schedules. Simple to use via PC 'windows' control software. USB port interface. No need for special interface cards. Field probe input for automatic level control. Suitable for use with any Power Amplifier and antenna / cell / chamber combination. Standard IEC61000-4-3 tests pre-programmed. EUT status input and prompt output. The RF1000/RF2000 are signal sources matched to the RFI immunity requirements of IEC61000-4-3. Features such as sine and pulsed modulation, programmable start and stop frequencies, frequency step, and dwell time are provided as standard. These units are essentially the same except that the RF1000 covers the range 30MHz to 1000MHz and the RF2000 covers 30MHz to 2400MHz. Both include powerful Windows control software with USB port interface. When used with the LaplaCell range of test cells, these synthesisers provide full automatic control of field level and all that is needed to provide an automated compliance test facility. Advanced features such as pre-scanning, display of EUT status against applied field level and full Windows compatibility are standard. These synthesisers has been conceived with the practical user in mind. To make the best use of the immunity test facilities for both compliance testing and product investigations, several useful features have been developed. These include: Powerful EUT monitoring with real time display correlated to field strength and frequency. Sweep can be continuous or 'pause on fault' or 'stop on fault'. Additional EUT excitation output, either pulsed or continuous. Flexible single frequency search mode. Automatic ramping of field strength and fine control of frequency. >>>
    View the product on laplace.co.uk Laplace Instruments Ltd
    GPC STANDARDS POLYCAL™

    GPC STANDARDS POLYCAL™

    Viscotek offers a full line of GPC standards for natural and synthetic polymer applications. PolyCAL™ Standards were developed as part of our commitment to provide "Complete Solutions for GPC/SEC Applications". PolyCAL™ Standards free GPC users from tedious standard preparation tasks by providing pre-weighed portions that are both accurate and easy to use. Pre-Weighed and Ready to Use PolyCAL™ Universal Calibration Standards (UCS) PolyCAL™ UCS standards consist of 6 sets of 12 individual narrow standards each. They are designed to be used for column calibrations, either conventional MW calibration with a concentration detector, or Universal Calibration with a viscometer detector. Time efficient, no weighing and no labeling, just add solvent Cost effective, multiple use afford less $ per calibration Accurate, precise and flexible concentration control with bigger vials and larger sample weights Excellent tool for lab-to-lab standardization and cross check One standard per vial, no resolution problems Detail pre-printed labels for lab notebooks (good for GLP/ISO) Broad MW range, 12 fractions provide excellent MW coverage Available for organic (PS, polystyrene) and aqueous (PEO, Polyethylene glycol/oxide) applications Also Available PolyCAL™ Triple Detector Standards (TDS) PolyCAL™ TDS standards consist of 6 sets of two standards each, one narrow and one broad. They are designed to be used for calibrating detectors used in triple detection, such as light scattering, viscometers, and refractometers. The narrow standard is particularly useful for determining detector volume offsets and peak broadening parameters. The broad standard is particularly useful for checking the calculations for correct MWD (Mn, Mw, and Mz are reported) and Mark-Houwink parameters, etc. In addition to the weight-average molecular weight Mw, the refractive index increment [dn/dc] and the intrinsic viscosity [h] are reported. These quantities can be used to calibrate, or check the calibration, of any and all three detectors. This response calibration is a must for accurate light scattering and viscometry work. Intrinsic viscosity [h] and refractive index increment [dn/dc] reported for all common solvents. Other benefits regarding accuracy and convenience are similar as listed above for UCS standards. >>>
    View the product on viscotek.com Viscotek Europe
    SPOT FLASH SYSTEM

    SPOT FLASH SYSTEM

    SPOT FLASH Flash chromatography is a fast and inexpensive separation technique for the purification of organic syntheses products, biological extracts, food- and environmental samples. The new SPOT FLASH system generation sets a new standard in flash chromatography regarding performance, productivity, flexibility and ease of use. It offers an amazing variety of possibilities for the purification of all kinds of substances - from milligrams to tens of grams >>>
    View the product on uk.vwr.com VWR