Equipement de connectique (translation in progress): suppliers, wholesalers and manufacturers on Hellopro
Search   


Equipement de connectique (translation in progress) :

371 products
Selection of 40 products among 371
00 SERIES - NIM-CAMAC (50 OHM MINIATURE COAX)

00 SERIES - NIM-CAMAC (50 OHM MINIATURE COAX)

Range of compact 50-Ohm coaxial connectors for a wide variety of applications; formed the basis of the NIM-CAMAC CD/N 549 standard. Benefits: # Small size and low weight allow high packing density # Concentric insert types (single contact, coaxial/triaxial) can be blindly inserted in any orientation and rotated into any direction for convenience Specifications: # 50-Ohm coaxial insert types >>>
View the product on lemo.com lemo france
CONNECTOR SYSTEM FFC / FPC-CONNECTORS ECO-LOCK 1.0

CONNECTOR SYSTEM FFC / FPC-CONNECTORS ECO-LOCK 1.0

Product features FFC / FPC-Connectors in 1 mm pitch 4-30 way versions Insertion of the flexible board without force (ZIF concept) Perfect interconnection on pressing down the cover Rectracting the cover enables the contacts to open again, thus releasing the flexible board Horizontal version (vertical version on request) Housings of high dimensional stability Termination: SMT Additional solder pads (horizontal version) >>>
View the product on stocko.de Stocko Contact
CONNECTORS - 602/RR & AFD - MEDIUM DENSITY CIRCULAR

CONNECTORS - 602/RR & AFD - MEDIUM DENSITY CIRCULAR

The The RR series is a range of medium density bayonet connectors for use in civil, defence and aerospace applications.Features & Benefits * High strength aluminium alloy standard, SS or aluminium bronze options * Fluid resistant inserts and seals * Rear release crimp contacts * Temperature range -65°C to + 200°C * Cadmium plating as standard, with nickel as optionTo EL2112 Pattern 602, PAN std 6432-1 (RR) & 6432-4 (602).Intermateable/intermountable with Mil-C-26482 Series 2, NAS1599 type B, NFL 54125, LN29500 and CECC 75201-001. The AFD series is similar to the RR range, but specific to Mil-C-26482 Series 2 QPL, UTE 93422 HE312 & Pan Std 6432-3. >>>
View the product on deutschuk.com Deustch Ltd
AIRLIQUID PN-MODULE - UP TO 10 BAR (145 PSI)

AIRLIQUID PN-MODULE - UP TO 10 BAR (145 PSI)

Our pneumatic AirLiquid PN-Module has been improved for use with liquids. Sealing material is Viton (FKM / Fluorcarbon rubber) providing high resitance against oils, gasoline, diesel, biodiesel or ethanol. The Module is available with one or two pneumatic nipples. Brass-valves, locked on socket side, ensure reliability, efficiency and high mechanical firmness within the durable industrial environment. With increased perfomance for the same price the AirLiquid PN-Module now replaces our past Pneu-Module. >>>
View the product on ges-electronic.de GES Electronic & Service Groupe - GES Electronic & Service
150A TO 400A 3, 4 AND 5 POLE CONNECTORS

150A TO 400A 3, 4 AND 5 POLE CONNECTORS

Designed to accommodate a high degree of misalignment between the sliding drawer and cabinet. Accepts standard cable lugs up to 120 mm2 onto threaded terminations. The connectors are available in three current ratings, 150, 200 and 400 amps and in 3, 4 and 5 pole versions. 150, 200 and 400 amp nominal current ratings 660V nominal operating voltage Hard silver plated brass or copper contacts Optional lead earth pin Flat or flange mounting Threaded stud terminations for crimp lugs TECHNICAL SPECIFICATION Nominal temperature rise at rated current: 40°C Ambient temperature range: -40°C to +70°C Recommended termination torque: M8 - 6Nm, M10 - 10Nm >>>
View the product on icoregroup.com ICORE INTERNATIONAL LTD
CONNECTOR/00 SERIES - MINI COAX

CONNECTOR/00 SERIES - MINI COAX

The 00 series of LEMO connectors have been designed to the NIM-CAMAC-CD/N 549 standard. The range of 50ohm connectors has a wide range of applications particularly within measurement and nuclear physics.The secure push pull latching mechanism is linked to the reduced size of the connector to provide a high packing density which can provide considerable space saving opportunities to the user. >>>
View the product on lemo.co.uk Lemo (UK) Ltd
COMPOSITE CONNECTORS - AMPHENOL AEROSPACE 38999

COMPOSITE CONNECTORS - AMPHENOL AEROSPACE 38999

Lightweight - 17% - 70% weight savings (17-40% weight savings vs. aluminum) (60-70% weight savings vs. stainless steel) See Composite weight comparison chart. Corrosion Resistance - available in standard MILDTL-38999 olive drab cadmium (175°C) and electroless nickel plating (200°C), both withstanding 2000 hours of salt spray exposure. The base material is able to withstand an indefinite exposure to salt spray. Durability - 1500 couplings minimum (in reference to connector couplings, not contacts) Extended Life Contact - Mil-approved plating process which provides 1500 couplings minimum >>>
View the product on peigenesis.com/ PEI-Genesis UK Ltd
MB SERIES CONNECTORS - IMPERIAL BULKHEAD

MB SERIES CONNECTORS - IMPERIAL BULKHEAD

The MB bulkhead is designed to give simple multiple tube connections where the need for a detachable plug does not exist. The unit is designed to fit into a hole of a given diameter and then secured in place by means of a back ring. * Up to 16 tubes can be connected with one simple hole in the panel or bulkhead. * Clear engraving showing tube numbers greatly reduces the risk of tubes being mismatched. * The standard material used ensures good resistance to chemical contamination and excellent operational durability at both low and high ambient temperatures. * The pleasing cosmetic appearance of the assembly ensures it will sit discretely in most applications. * All the push in fittings used are barb free and tubes can be therefore fitted and removed countless times without any damage to the connector or application. * The cost of the MB bulkhead ensures that not only is it superior functionally, but will save time in installation and in future maintenance situations. Technical Data Fittings : Legris carstick as standard (others to order) Body Material : Acetal Maximum pressure : 18 bar Vacuum capacity : Reduced pressure to 755 mm .hg Operating temperature range : - 40ºc to 80ºc Acceptable panel thickness : 0 to 5 mm (.190”) Working medium : Compressed Air (for others please consult factory) Place of origin : All manufactured in the UK Standard tube sizes : 1/8, 1/4, 5/16, 3/8” Dimensions : See drawing section of this brochure >>>
View the product on pneutherm.com Pneu-therm Ltd
DUAL-CHANNEL PLASTIC OPTICAL FIBERS

DUAL-CHANNEL PLASTIC OPTICAL FIBERS

The dual-channel fiber optic rotary joint has optimum features in terms of electromagnetic compatibility, interference resistance and life. It allows a bidirectional transmission of two isolated optical channels. The rotary joint is optimized for the use of plastic optical fibers and can be connected in an optical transmission network easily – especially for industrial applications. Basically, this unit will be delivered with a standard cable length of 1 meter and 4 FSMA connectors. Other cable lengths, cable types or customer specific cables are available upon request. Because of the passive design, the dual-channel POF is best suited for every data protocol and data format and allows for a combination with mechanical slip rings, as well. Classic applications: Automation Wind energy Robots and Handling machines Special Machinery Optional: Customer specific cables and connectors >>>
View the product on schleifring.com/en/index.php SCHLEIFRING SYSTEMS LTD
ELECTRICAL CABLE MALE - 3 POLE SCREW TERMINATION

ELECTRICAL CABLE MALE - 3 POLE SCREW TERMINATION

Male connectors 'field installable' with screw termination. Suitable for 0.75 to 4.0mm sq cable with rigid or stranded cables. Rated at 20A, IP68. For standard mains applications there are black or grey colour, part number code at end denotes colour (0 = grey, 1 = black). For multi-phase systems (250v/400V) a green coloured connector is available. The 'Standard' or 'Multi-phase' systems are mechanically coded, this means only associated pairs of male & female can be connected with the correct polarity. The male connector locks into the female securely with a locking latch. The two can only be unplugged by inserting a screwdriver to unlatch the locking mechanism. >>>
View the product on selectronix.co.uk Selectronix Ltd
GIS/TRF TERMINATION/CONNECTOR 84-420 KV, APEGA

GIS/TRF TERMINATION/CONNECTOR 84-420 KV, APEGA

The cable termination consists of an epoxy insulator standing on a base made of an aluminium casting. The field controlling component is a stress cone made of rubber. The insulator is filled with synthetic insulating oil. A flange for insulated mounting is integrated in the epoxy insulator. A pressure ring is also included. The top bolt which is included in the kit must be selected in accordance with the table. * Reliable * Tested * Time saving screw technique * Flexible, fits big cables * Can be assembled horizontally on the ground before installation >>>
View the product on abb.co.uk ABB Ltd
19 PIN SCREW COUPLING LIGHTING CONNECTOR ABLC

19 PIN SCREW COUPLING LIGHTING CONNECTOR ABLC

ABLC Series. 19 Pin Lighting Connector Designed for the professional lighting industry Fully Compatible with corresponding competition types Rapid coarse thread screw coupling. Aluminium shells with heavy duty coupling nut for secure handling. Crimp or solder contacts. Long backshell for 'PG', cable clamp adaptor or 'basket weave' cable grip accessory. Earthing version with integral shell earth tag & first make last break contact. Black cadmium free hard wearing surface finish. Further details on the ABLC range available on request from the factory. Specification Standard Materials & Finishes Shell: Aluminium alloy, black protective finish Insulator: Polychloroprene rubber. Grommet: Contacts: Copper alloy, gold plated Mechanical Features Coupling: Coarse thread Polarisation: Key / Keyway Contact Type: Solder. Contact Arrangements: 19 contacts. Standard Materials & Finishes Maximum Contact Current Ratings: 41 amps max, 23 amps rated. Voltage Ratings: Working 700v d.c., 500V a.c. Contact Resistance: 5 milliohms max. Temperature Rating: -55°C to +125°C. >>>
View the product on ttabconnectors.com AB CONNECTORS LTD
AB05 - MINIATURE BAYONET CONNECTORS

AB05 - MINIATURE BAYONET CONNECTORS

These connectors feature bayonet coupling, or an alternative ’push-pull’ version in shell size 10 and 12 for quick release applications.AB05 connectors offer economical lightweight solutions for interconnection needs in commercial and industrial applications.Insulators are polychloroprene and provide excellent solvent and insulation resistance and environmental sealing.Accessories include straight outlets, cable clamps, grommet sealing nuts, general duty adaptors and protective caps. >>>
View the product on aerco.co.uk Aerco Ltd
EURO BATTERY CONNECTORS

EURO BATTERY CONNECTORS

FEATURES Streamlined design 3 hexagonal voltage coding pins for wet, dry/gel and air supply Optional air voltage key 2 main contacts, 4 auxiliary contacts, voltage key and air supply BENEFITS Lower cost, ease of assembly and improved functionality Coding pins marked for 24V, 36V, 48V, 72V, 80V, and 96V provide additional safety and prevent cross voltage mating "A" series for American wire gauge cable E" series for metric cable - intermatable with European competitive products >>>
View the product on andersonpower.com Anderson Power Products
CONNECTOR > STANDARD - PLUGS AND SOCKETS

CONNECTOR > STANDARD - PLUGS AND SOCKETS

STANDARD PLUGS AND SOCKETS TYPES: Copper, E, J, K, N, R/S and T * A range of standard sized connectors with round pins to suit the thermocouple type being used * Intended for use in more industrial applications * Plugs fitted with solid thermocouple pins * All contacts are polarised to ensure correct connection * Cable clamps available for securing cable * Maximum continuous operating temperature 220°C >>>
View the product on labfacility.co.uk Labfacility Ltd
CYLINDRICAL FUSES

CYLINDRICAL FUSES

PHYSICAL SIZES There are numerous physical sizes of electronic fuses, including subminiature fuses. The most common cylindrical designs are 5x20mm and 6,3x32mm. Subminiature fuses are often used when board space is limited. For applications of this type there are both through-hole and surface mount device available. Standard package size for surface mount fuses are 1608, 3216 and 6125. These sizes are standard throughout the electronic industry. Through-hole axial and radial leaded products allow fuses to be PCB mounted. Standard 5x15 and 5x20 fuses fitted with leads can also be mounted in this way. GENERAL INFORMATION Basic Fuse Technology Miniature fuses serv to main purposes: a) To protect components, equipment and people from risk of fire and shock risk caused by overcurrents. b) To isolate subsystems from the main system once a fault has occurred. Overcurrents Overcurrents exist when the normal load for a circuit is exceeded. It can be either an overload or short circuit. An overload is any current flowing within the normal circuit path that is higher than the normal circuit full load current. A short circuit is an overcurrent which greatly exceeds the normal full load current of the circuit. Components and equipment can be damaged by both types of overcurrent. Selecting overcurrent protection During normal load current conditions, the fuse must carry the normal load current of the circuit without nuisance opening. However, when an overcurrent occurs the fuse must interrupt the overcurrent and withstand the voltage across the fuse after arcing. To properly select a fuse the following items must be considered: • Voltage rating (ac or dc voltage) Available short circuit current Characteristics of equipment or components to be protected Ambient conditions Available board space Automatic or manual insertion Ease of field service Full load currents In-rush characteristics Standards requirements Type of mounting Reliability Electronic circuits frequently exhibit surges, caused by capacitors charging, motors being momentarily stalled, or high voltage components sparking over. It is important that designers take account of these temporary conditions during fuse selection. The ability to resist surges is a function of the fuse design relative to the surge pulse, duration, frequency, etc. Voltage ratings The voltage ratings of the fuse must be greater than or equal to the circuit voltage. Because the fuse has such low resistance the voltage rating becomes critical only when the fuse is trying to open. The fuse must be able to open quickly, extinguish the arc after the fuse element has melted and prevent the system open-circuit voltage from re-striking across the open fuse element. Current ratings Each fuse is marked with a nominal current rating. Several factors can affect the ability of the fuse to carry this rated current. First the base material of the clip in which the fuse is mounted may greatly affect the performance of the fuse. Another important factor is the conductor size used to connect the fuse to other circuit components. If the conductor is too small, it will generate heat. That extra heat will be seen by the fuse, causing the fuse to open before it should. It is also important that the fuse be installed with clean and tight connections. If the connections are dirty or loose, they will cause increased resistance, generating extra heat. That heat will lead to a shortened fuse life. Breaking capacity A fuse must be able to open the circuit under a short circuit without endangering its sorroundings. The breaking capacity of a protective device is the maximum available current, at the rated voltage, that the device can safely open without the possibility of rupturing. Fuse resistance In most applications, the voltage drop across the fuse due to its internal and contact resistances is negligible. There are, however, certain critical applications where the fuse resistance must be considered and it is important that the circuit designer understands the fuse characteristics in order to select the proper fuse. GLOSSARY OF TERMS Ampere squared seconds I2t A measure of heat energy supplied to a circuit while the fuse is clearing a fault. It can be expressed as melting I2t, arcing I2t, or the sum of them “clearing I2t”. This is usually used as a measure of short circuit performance Arcing time The amount of time from the instant the fuse link has melted until the overcurrent is interrupted, or cleared. Clearing time The total time between the beginning of the overcurrent and the final opening of the circuit at the rated voltage by an overcurrent protective device. Clearing time is the total of the melting time and the arcing time. Fast acting fuses A fuse which opens on overload and short circuits very quickly. This type of fuse is not designed to withstand temporary overload currents with some electrical loads. Overcurrent A condition which exists on an electrical circuit when the normal load current is exceeded. Overcurrents take on two separate characteristics: overloads and short circuits. Overload Can be classified as an overcurrent which exceeds the normal full load current of a circuit. Resistive load An electrical load which is characterised by not having any significant in-rush current. When a resistive load is energized, the current rises instantly to its steady state value, without first rising to a higher value. RMS Current The RMS (root mean square) value of any periodic current is equal to the value of the direct current which, flowing through a resistance, produces the same heating effect in the resistance as the periodic current does. Short circuit Can be classified as an overcurrent which exceeds the normal full load current of a circuit by a factor many times (tens, hundreds, thousands greater). Time delay fuses A fuse with a built-in time delay that allows temporary and harmless in-rush current to pass without operating, but is so designed to open on sustained overloads and short circuits. Time lag (surge proof) A fuse which can withstand short high current pulses and is particularly suitable for television sets, amplifiers, etc. Voltage rating A maximum open circuit voltage in which a fuse can be used, yet safely interrupt an over-current. Exceeding the voltage rating of a fuse impairs its ability to clear an overload or short circuit safely >>>
View the product on omegafusibili.it OMEGA FUSIBILI
AUTOFLEX® DEFROSTER HOSE

AUTOFLEX® DEFROSTER HOSE

Dayco® Autoflex® Defroster Duct HoseDesigned for all under-dash air connections, hot or cold, including defroster vents and fresh air intakesDayco’s Autoflex Defroster Duct Hose is made with tough, lightweight, and flexible reinforced vinyl, ideal for all vehicle air ducting, either hot or cold. It installs in minutes, and can be clamped or taped to existing fittings. Available in 15 I.D. sizes, it services a wide range of applications. Individually boxed 6' lengths are compressed to 18" per box for easy stocking. >>>
View the product on dayco.com Dayco Europe Ltd
CONNECTORS FOR FLAT CABLES - SMC - 1.27 MM (0.05)

CONNECTORS FOR FLAT CABLES - SMC - 1.27 MM (0.05)

The SMC line of versatile connectors offers a great deal of design application flexibility. Different modules (such as the MiniBridge, straight and angled male and female multipin connectors) in combination with other options (e.g. IDC versions) afford users the freedom for an optimal assembly design. The connectors are reliably produced on state-of-the-art, fully automatic manufacturing machines. Due to the high contact density and small space required, SMC connectors offer a number of new application possibilities. The precision manufactured contact guarantee a reliable mate. SMC connectors are available in several different heights. The combination of standard profile and low male and female connectors support four different board-to-board stacking heights (8.0 - 14.0mm). Pitch: 1.27mm (.05 ") Pins: 12, 26, 50, 68, 80 Termination: Pressfit, IDC, SMT Standard: N.A. Datarate: up to 3 GBit/s >>>
View the product on erni.com ERNI
ELECTRICAL INTERFACE MODULES (EIMS)

ELECTRICAL INTERFACE MODULES (EIMS)

The Electrical Interface Module (EIM) is connected to the copper communication link. The module receives signals from the copper link, conditions them and makes the signals available to the backplane for conversion. The EIM also accepts signals from the backplane and transmits the signals to the attached copper link. EIM part numbers always begin with 2C. It is important to select the correct EIM for the copper protocol being converted. For example, the 2C02 is the model which is compatible with GE Fanuc networks. Key Selection Criteria: What communication protocol is being converted? What is the baud rate? >>>
View the product on weedinstrument.com/product_groups/fiber.html Weed Instrument




  Search    
 
 
 
Search
See all of the sector's products : Electricity/Electronics