Electrophoresis: suppliers, wholesalers and manufacturers on Hellopro
Search   


Electrophoresis :

23 products
Select the category
    Selection of 23 products among 23
    PARTIAL DISCHARGE MONITORING - INDIPARD® IDP 16

    PARTIAL DISCHARGE MONITORING - INDIPARD® IDP 16

    Evaluation Unit for Online Partial Discharge Monitoring Brief description Online monitoring, surveillance and diagnosis of partial discharges Alerting in the case of limit violation Event-driven maintenance Can be retrofitted on old installations Search coils for coupling without physical contact Sensors with CapEye® interface connectable Can be expanded for up to eight monitoring points Designed as an operational measuring instrument and for constant duty Compact design and practically orientated installation system Adjustable limits and interference suppression per input Self monitoring and alerting in the event of device failure Can be configured by user on PC Optional: Data transfer via fixed-network or GSM modem Measured value acquisition with PC >>>
    View the product on may-elektronik.de May Elektronik
    ALLTIMA™ HP HILIC COLUMN

    ALLTIMA™ HP HILIC COLUMN

    Hydrophilic Interaction (HILIC) Columns for highly polar basic analytes Superior retention of highly polar compounds Increased sensitivity and lower detection limits with LC/MS Hydrophilic Interaction Chromatography is ideal for separating and retaining very polar compounds that may not retain on traditional reversed phase packings. Unlike reversed phase columns, HILIC columns retain highly polar compounds with only small amounts of water in the mobile phase. These more volatile mobile phases increase sensitivity with LC/MS applications >>>
    View the product on discoverysciences.com Grace Davison Discovery Sciences
    BROADBAND METER

    BROADBAND METER

    The perfect solution for the monitoring / measurement of RF pollution. The Broadband meter was designed as a general purpose electromagnetic measurement tool. It detects electric and magnetic fields from power line frequencies up to several GHz. It is unique in its combination of a magnetic AC gaussmeter, electric field meter and RF field strength meter, all in one small package. Therefore it can be used to study and measure the magnetic fields produced by electrical power cables (including overhead lines), the fields produced by video displays, right through to the radiation emitted by microwave ovens, mobile phones and wireless LANs. Other applications include the measurement of RF environments to minimise health risks, detection of leakage from microwave ovens and detection of concealed transmitters. Specifications Gauss Meter: 0-3 range: 0.2 - 3 milligauss. 0-100 range: 0.3 - 100 milligauss. Freq. range: 50 - 500Hz flat. Accuracy: ±20 % to 50MHz Electric field: Range: 10 V/m - 100 KV/m Freq. range: 40 - 100KHz. Accuracy: ±25 % RF Field Strength: Range: 0.01 - 1 KV/m Freq. Range: 100KHz - 2.5 GHz flat. Indication: Analogue meter with rotary range change switch. Power: 9V (PP3) internal Battery. Battery test reading on meter. Size: 15 cm x 9 cm x 3 cm >>>
    View the product on laplace.co.uk Laplace Instruments Ltd
    NEW SUPER FAST PERFORMANCE - WAVEQUEST

    NEW SUPER FAST PERFORMANCE - WAVEQUEST

    WaveQuest the CE4300 Dynamic Absorbance Detector (DAD) is an ultra high speed scanning powerful alternative to Photo Diode Array detectors. HPLC method development, purity determination, R & D and Variable Wavelength Monitoring are all possible with the highest quality. Dual wavelength monitoring and wavelength programming are also provided. The design is based on a double beam spectro-photometer concept with ultra fast wavelength scanning over the range 190-700nm. This dynamic scan provides UV spectra in only 200mS, previously only possible using the static optical system of a PDA detector. Powerful signal processing software has been developed which enables very high quality “on-the-fly” scans to be triggered by eluting peaks without the peaks being degraded. Spectral data is transferred by Cecil’s DataStream software to a PC workstation where the same software offers spectral manipulation and processing, library facilities and the export of data to applications such as Excel, word etc. All data may be stored on disk. Eluting peaks may be integrated at the same time as purity and peak identification is carried out. Quantitative evaluation and reporting is carried out by Cecil’s CE4900 PowerStream software, which is combined with DataStream software. >>>
    View the product on cecilinstruments.net Cecil Instruments
    ANALYTICAL NOVOGROM COLUMNS

    ANALYTICAL NOVOGROM COLUMNS

    ANALYTICAL NovoGROM COLUMNS – 3.0, 4.0, and 4.6 mm i.d. The analytical NovoGROM HPLC column system is many-fold proven. These columns can be connected to any HPLC system either conventionally via 1/16" capillary, ferrules and screw fittings or dead volume free via the NovoGROM Quick connectors. Standard dimensions are 3, 4 and 4.6 mm internal diameter and lengths of 2, 4, 6, 10, 12.5, 15, 20, 25 and 30 cm. Guard columns, i.e., protective precolumns, are available in the lengths of 5, 10 and 20 mm. Columns may be filled as often as is required in the economical refill service. Use of the 3 mm i.d. column results in a reduction in the consumption of solvent of ca. 43% or 57% compared to the 4 mm and 4.6 mm i.d. columns respectively. This not only reduces costs, but is also active environmental protection. All NovoGROM columns can be supplied with any of the stationary phases listed on GROM websites or in this GROMHPLC catalogue (see pages 12/13 and 144-151). Alternatively, they may also be packed by the GROM filling service with any stationary phase specified by the customer. >>>
    View the product on grom.de Grom Chromatography Groupe - Grace
    LACHROM ELITE

    LACHROM ELITE

    A masterpiece of modern technology The new generation LaChrom Elite® system from VWR-Hitachi is a robust, versatile and well designed HPLC instrument line with excellent precision and sensitivity as well as minimum sample carry-over. Designed for ease of use, all operational and maintenance parts are accessible from the front. Together with the comprehensive and FDA compliant chromatography data system EZChrom Elite® offers a high degree of capability in data processing and chromatography systemcontrol(1). >>>
    View the product on uk.vwr.com VWR
    COLUMN HPLC - WYATT COMET™

    COLUMN HPLC - WYATT COMET™

    Wyatt COMET™ (Cell Operation and Maintenance Enhancing Technology)Light scattering is the premier technique for absolute macromolecular characterization. However, it is well known that in order to achieve the most accurate and reproducible results, one must maintain scrupulously clean optics and mobile phase. Even when the mobile phase is pre-filtered, chromatography columns continuously shed small particles that, over time, can contaminate even the cleanest optics. This is where the Wyatt COMET™ (Cell Operation and Maintenance Enhancing Technology) concept becomes indispensable. This new device may be integrated with the flow cell manifold of a DAWN DSP, DAWN EOS, miniDAWN or miniDAWN Tristar and applies a radio frequency ultrasonic field specially tuned to the flow cell structure itself. Unlike traditional ultrasonic cleaning methods, the field produced by the COMET device is resonant with the flow cell bore and does not produce cavitation bubbles that might damage the glass surface-nor does it form bubbles that would affect the scattering signals themselves. When used on a regular basis, the need to remove the flow cell for cleaning may be postponed indefinitely. The COMET loosens particles that may have adhered to the cell walls and removes them on a daily basis. In addition, the periodic activation of the device can prevent the adhesion of new particles. Moreover, the device operates in-situ while the mobile phase is flowing through the cell. There is no need to disconnect any fluid fittings, change solvents, or disassemble anything. Wyatt Technology's Chief Executive Officer, Dr. Philip Wyatt noted that successful light scattering measurements come from minimizing dust and flare from the laser beam. "Up until now, our patented flow cell design has addressed these problems in three ways. First, the critical entrance and exit windows of the flow cell are located far from the scattering center to reduce the effect of contaminated windows. Second, the laser light source is focused into an extremely small beam diameter so that particulates and other contaminants on the walls are not illuminated. Third, the flow cell can be easily removed, manually cleaned, and reinstalled without perturbing the optical alignment. What has always been required, however, is an on-line method of maintaining flow cell cleanliness. That's what is so exciting about this novel device." >>>
    View the product on wyatt-europe.com Wyatt Technology Europe
    DOCUMENTATION PACKAGES - IQ/OQ

    DOCUMENTATION PACKAGES - IQ/OQ

    The Faster Way to Validation ! Our IQ/OQ validation procedures (disk and hardcopy) mark YSI Life Sciences's entry into validation services for our markets. Installation qualification (IQ) and operational qualification (OQ) are processes which manufacturers of FDA-regulated products must validate with each instrument that is integrated into a manufacturing system. The availability of IQ/OQ documentation directly from the instrument's manufacturer can save you precious time and resources. >>>
    View the product on ysi.com/lifesciences.htm YSI Life Science Groupe - YSI
    RF POWER SYSTEMS VARIOMATCH AUTOMATIC MATCHING NETWORKS

    RF POWER SYSTEMS VARIOMATCH AUTOMATIC MATCHING NETWORKS

    High tuning accuracy and speed enable VarioMatch™ automatic matching networks to deliver extremely consistent power across a wide range of plasma load conditions (600 W to 5 kW, 2 to 40.68 MHz). Optimized for capacitively coupled plasma and CO2-laser loads, these highly reliable devices increase yield and productivity. VarioMatch networks are easy to operate and integrate with any existing system. Their compact, plug-and-play design eliminates the need for external controllers and enables easy mounting close to the chamber. Although they are compatible with any RF generator, VarioMatch networks offer unique benefits when combined with Advanced Energy® Cesar® RF power supplies. >>>
    View the product on advanced-energy.com Advanced Energy Industries UK Ltd
    DAVISIL® CHROMATOGRAPHIC SILICA MEDIA

    DAVISIL® CHROMATOGRAPHIC SILICA MEDIA

    Recognized worldwide as media of high purity, DAVISIL® silica's are the cornerstone of Grace's matrix of selective chromatography products. Consisting of granular shaped particles with excellent mechanical and structural properties, DAVISIL silicas are versatile, consistent and reliable. They are ideal for small columns, HPLC, solid phase extraction, flash chromatography, and scale-up to industrial process applications. DAVISIL silicas are available in particle sizes from 6 µm to 3,000 µm and pore sizes from 30 Ĺ to 2,500 Ĺ. A variety of well-defined standard grades are available as indicated in the tables below. Please contact your Grace representative for consultation and quotation regarding specific requirements. >>>
    View the product on alltechweb.com Alltech Associates Applied Science Ltd
    PARTIAL DISCHARGE MONITORING - INDIPARD® IDPS

    PARTIAL DISCHARGE MONITORING - INDIPARD® IDPS

    Sensors for Online Partial Discharge Monitoring Brief description Active partial discharge sensors Integrated preamplifier Search coil for coupling without physical contact Inductive coupling for monitoring individual components 3-phase CapEye® amplifier for capacitive coupling electrodes Can be retrofitted in old installations Compact design and practically orientated assembly system Powered and monitored by Indipard evaluation unit Field of application and benefits The partial discharge (PD) sensors, together with the INDIPARD evaluation unit, form an online monitoring system for insulation monitoring of high-voltage and medium-voltage installations. Continuous monitoring of partial discharge activities offers the opportunity of detecting a worsening or serious change in the condition of the insulation of the equipment at an early point, thus giving the user the opportunity to intervene in good time so as to prevent more serious damage. Mode of operation The PD sensors are installed in the parts of a medium-voltage or high-voltage installation at risk. They detect the highfrequency electric fields generated by the partial discharges and forward them to the IDP16 via coaxial cable. The sensors are active, i.e. they feature a preamplifier. It is powered by the evaluation unit via the coaxial cable. Depending on application, either search coils, inductive PD sensors, capacitive coupling electrodes with a CapEye® amplifier or devices with CapEye® interface may be used. Search coil The search coil performs coupling without physical contact. It must be fitted in the electric field between high voltage and earth. Its metal bar forms a capacitive coupling electrode. Its range is approx. 2 m in open installations and approx. 1 m in enclosed installations. It is particularly suitable for retrofitting in old installations. Complete installation kits are available for specific types of installation. Inductive PD sensor The high-frequency current generated by partial discharges is detected with respect to earth with the aid of a Rogowski coil. Such a coil is suitable for monitoring individual components such as a transformer.. In this case, it must be ensured that the section to be monitored features only one defined earthable point and is otherwise installed on insulated mountings. CapEye® amplifier The CapEye® amplifier features three inputs for connection to capacitive coupling electrodes such as capacitive insulators or capacitive coupling electrodes. The range is approx. 5 m from the installation location in both directions of the conductor but ends after approx. 1 m in cable. CapEye® amplifiers have improved common mode rejection cabability. The CapEye® amplifier is particularly suitable for monitoring twin switchgear cells, in the case of multi-tier design or in the case of multiple separation of switchgear cells. Voltage test system with CapEye® amplifier The Capdis-Sx-C is an integrated, capacitive voltage test system in accordance with IEC 61243-5, either with or without contact outputs. It is also fitted with a CapEye® amplifier and thus allows monitoring of the voltage and condition of the insulation on the same coupling electrodes. Technical data Connection cable to evaluation unit Type Coaxial cable Length up to 50 m per input Search coil IDPS-A-F Rated meas. range 400 pC Antenna bar length standard 50 cm, min. 30 cm, max. 200 cm Installation with 2 spacers directly on an earthed surface within the switchgear cubicle Min. earthing clearance 2 cm Opt. earthing clearance 4 ... 10 cm Detection range with 4 cm earthing clearance min. 100 cm in enclosed installations min. 200 cm in open installations Perm. amb. temp -20° ... 55°C in operation -30° ... 70°C for storage Connection F socket and earth >>>
    View the product on may-elektronik.de May Elektronik
    GRACESMARTTM HPLC COLUMN

    GRACESMARTTM HPLC COLUMN

    Smart Quality Smart Performance Smart Value Grace Davison Discovery Sciences sets a new standard in HPLC columns. From the silica particle to the finished product, our streamlined manufacturing delivers smart quality and smart performance, at an exceptional value. GraceSmart™ HPLC Phases use high purity silica and are monomerically bonded with uniform coverage. This translates into symmetrical peaks for acids/bases, and predictable reversed phase selectivity. GraceSmart™ columns show similar or better efficiency and asymmetries for challenging base and acid components in comparison to industry leading columns. >>>
    View the product on discoverysciences.com Grace Davison Discovery Sciences
    MICROALERT

    MICROALERT

    sensitive RF detector (-S) or an alarm to warn of hazardous RF radiation (-P) Radio / microwave alarm is the size of a small pager, just 5.7cm x 4cm x 2cm. The high sensitivity version is ideal for anyone who needs to find out exactly what is emitting radio or microwaves, including hidden sources. An industrial version is triggered by higher levels of radiation and is ideal for personnel alarm use when working near transmitters or RF sources. The alarm provides an audio output that bleeps when the pre-set level is reached, the frequency of the bleeps increases if the signal level increases. The sensitive version will detect a typical mobile phone base station from 100 metres, a mobile phone at 6 metres and a microwave oven at 3 -10 metres. The sensitivity can be adjusted to suit the application with a small adjustment knob. >>>
    View the product on laplace.co.uk Laplace Instruments Ltd
    SUPERB PERFORMANCE HPLC - ADEPT SERIES

    SUPERB PERFORMANCE HPLC - ADEPT SERIES

    Adept Series HPLC systems and modules offer top grade performance, are economically priced and designed for all applications including method development, quality assurance, quality control, pharmaceutical and ion chromatography. A revolutionary new UV-Visible Dynamic Absorbance Detector (DAD), offers all the spectral capabilities of a Photo-Diode Array Detector (PDA), with greatly improved performance when used as a variable wavelength detector (VWD). Pumps, UV detectors and system control modules may be stacked vertically for the smallest possible space requirement or in lower profile where space permits. State of the art design, based on 30 years of HPLC design experience, is combined with up to the minute software, designed to operate in Windows XP, but may also be used with Windows 98 and 2000. It offers the easiest possible use with full system control, spectral and data processing. Ultra Fast Scanning Detector Cecil Instruments introduce WaveQuest, a breakthrough in UV-Visible detector design. A true alternative to Photo Diode Array detectors. Super fast wavelength scanning, scanning UV spectrum in 200 ms. Powerful spectral processing software for R&D, method development, purity determination etc. Absolutely top performance as variable wavelength detector, with data processing by PowerStream software, another Cecil Instruments development. >>>
    View the product on cecilinstruments.net Cecil Instruments
    MICROBORE COLUMNS

    MICROBORE COLUMNS

    NovoGROM Microbore Columns – 1 and 2 mm i.d. – Many of the modern biochemical applications requiring micro-column HPLC may be conveniently solved by the employment of NovoGROM microbore columns. With 2 or 1 mm i.d. columns, a 4-fold or 16-fold increase in sensitivity, respectively, is obtained relative to conventional 4 mm i.d. columns. At the same time, the solvent consumption at constant linear flow-rate decreases by 75% or 93% respectively. The requirements for microbore HPLC (in particular constant flow at low volumetric flow-rates) are fulfilled by all modern HPLC systems, so that customers can take advantage of this modern form of HPLC simply by the use of NovoGROM microbore columns. According to customers requirements, NovoGROM microbore columns can be supplied packed with any of the stationary phases described in this catalogue, or can be packed by the GROM column-filling-service with any other (eg., customer‘s own) stationary phase. >>>
    View the product on grom.de Grom Chromatography Groupe - Grace
    LACHROMULTRA™ SYSTEM

    LACHROMULTRA™ SYSTEM

    The High-Speed HPLC System • Ultra-fast chromatography • Superior resolution • Unique flexibility • Enhanced reliability • A quantum leap in productivity The LaChromUltra™ system from VWR-Hitachi is a very versatile high-performance HPLC showing excellent precision and sensitivity and with minimal sample carryover. It has been optimized for high-speed chromatography with both particulate and monolithic columns and is equipped with a number of special functions. At the same time it is excellently suited to all standard HPLC applications. The LaChromUltra™ system is very user-friendly as all parts relevant to operation and maintenance are accessible from the front. Together with the comprehensive and FDA-compliant chromatography data system EZChrom Elite® it offers a high degree of capability in data processing and chromatography system control. >>>
    View the product on uk.vwr.com VWR
    WYATTQELS (QUASI-ELASTIC-LIGHT-SCATTERING) INSTRUMENT

    WYATTQELS (QUASI-ELASTIC-LIGHT-SCATTERING) INSTRUMENT

    WyattQELS™ On-Line Quasi Elastic Light Scattering from your HPLCThe WyattQELS (Quasi-Elastic-Light-Scattering) instrument contains a real time digital correlator. The correlator measures the autocorrelation function of the intensity signal from any one angle of the DAWN or from the 90 degree location of the miniDAWN. The correlator then calculates the hydrodynamic radius at each elution time in order to provide hydrodynamic radii over an entire chromatographic peak. Unlike many other dynamic light scattering instruments, the WyattQELS detector, when interfaced to the DAWN, allows one to measure correlation as a function of angle. Particles larger than 150nm may scatter relatively little light at 90 degrees because of intra-particle interface or "Mie scattering". This effect may cause significant distortion in computer particles size distribution for some kinds of polydisperse samples. Since the WyattQELS optical fiber can be moved easily to any one of the 18 DAWN angles, the measurements can be optimized for the best results for particles that are very large. With most other instruments, which only make measurements at 90 degrees, if large particles are present, the signals may be low or lost altogether. But with the WyattQELS you can always move the optical fiber to a lower or a higher angle. WyattQELS Features include: Multiple Tau correlation design with a fixed range of channel from 480 nsec to ~1 hour (real-time). No sample time optimization required! A total of 264 channels with input data format of 5 bit for the first 16 channels, the the sample time doubles every 8 channels and the data width is incremented 1 bit for every set of channels. No pre-scaling required. >>>
    View the product on wyatt-europe.com Wyatt Technology Europe
    PORTABLE PARTIAL DISCHARGE TESTER - INDIPORT IDC 20

    PORTABLE PARTIAL DISCHARGE TESTER - INDIPORT IDC 20

    Portable partial discharge tester for switchgear Brief description Partial discharge tests in a few minutes without having to shutdown Checkable and reproducible due to artificial PD source Specially designed for medium-voltage switchgear Utilises the coupling capacitance of the voltage testing system Fits directly to HR interfaces or equipment and sensors with CapEye®-Interface Read off and/or record measured values Long-term observations, trend recognition Data recorded on SD memory cards Evaluation on a PC with standard software Light, portable and maintenance-free Can be used without a PC Optional: sensors to record weather data simultaneously: pressure, temperature, humidity and dew point Optional: sending text messages via GSM modem Area of application The use of partial discharge (PD) tests on high-and medium-voltage installations is now undisputed. Manufacturers test their equipment before delivering it to customers. Many customers ask for a repeat test after assembly and before commissioning on site. However, these do not include the major weak points for operators, namely the cable terminations. Subsequent regular testing requires the complete isolation of the installation, is very costly and is therefore generally dispensed with. INDIPORT is a portable partial-discharge measuring system. It is designed for use during operation and does not need the installation to be isolated. Installations can consequently be tested at any time and at reasonable cost. In addition to instantaneous values, the INDIPORT can also be used for long-term measurements, including climate measurements. Method of operation INDIPORT, with its preamplifier, uses the existing capacitance taps on the switchgear, such as the HR interfaces or voltage testing systems with CapEye® interface. Sensors in the INDIPARD partial discharge monitoring system can also be connected directly. The normal operating voltage is used as the test voltage. Pulses with a known charge are fed in from the adjacent cell with the IDP-SRC PD simulator, again via the capacitance tap, and compared with the display. This means the measurement results are reproducible and comparable with other stations. Partial discharges often occur sporadically, depending on the weather. In order to be able to obtain any meaningful information about the condition of the insulation in an installation, observation over an extended period of time is necessary. Consequently, the INDIPORT includes a complete data logger for long-term data capture in addition to the momentary display with a phase diagram. SD or SDHC memory cards of up to 32 GB storage capacity can be used for data recording. PD measurements from different time periods and locations can only be compared if the most important climate data is taken into account. To do this, INDIPORT simultaneously captures the partial discharge activity, relative humidity, temperature, dew point and air pressure at adjustable time intervals. For evaluation, the memory card is removed from the unit and can then be evaluated on a PC with a card reader and spreadsheet program. INDIPORT can be combined with a GSM modem. When a PD occurs, the unit calls the service personnel by text message. This is particularly important when searching for and localising sporadic PDs. INDIPORT is supplied with its accessories in a study plastic carrying case. >>>
    View the product on may-elektronik.de May Elektronik
    VISIONHTTM HPLC COLUMN

    VISIONHTTM HPLC COLUMN

    Ultra-fast separations with superior efficiency, sensitivity and resolution 12,000psi pressure rating compatible with all ultra high-pressure LC systems Optimized 1.5µm media balances speed and back pressure for maximum performance Grace® VisionHTTM columns introduce a new level in ultra high-efficiency HPLC. The powerful combination of low volume, high pressure hardware, and optimized high speed 1.5µm media gives seperations a whole new clarity. Complex samples resolve 95% faster with 4x greater sensitivity when compared to traditional 150 x 2.1mm, 5µm columns. >>>
    View the product on discoverysciences.com Grace Davison Discovery Sciences
    RF1000/RF2000 SYNTHESISER

    RF1000/RF2000 SYNTHESISER

    RF1000 Synthesiser (30MHz - 1GHz) RF2000 Synthesiser (30MHz - 2.4 GHz) PC controlled RF synthesisers for immunity testing up to 2.4GHz matched to the requirements of IEC61000-4-3 and featuring automatic scanning to pre-programmed schedules. Simple to use via PC 'windows' control software. USB port interface. No need for special interface cards. Field probe input for automatic level control. Suitable for use with any Power Amplifier and antenna / cell / chamber combination. Standard IEC61000-4-3 tests pre-programmed. EUT status input and prompt output. The RF1000/RF2000 are signal sources matched to the RFI immunity requirements of IEC61000-4-3. Features such as sine and pulsed modulation, programmable start and stop frequencies, frequency step, and dwell time are provided as standard. These units are essentially the same except that the RF1000 covers the range 30MHz to 1000MHz and the RF2000 covers 30MHz to 2400MHz. Both include powerful Windows control software with USB port interface. When used with the LaplaCell range of test cells, these synthesisers provide full automatic control of field level and all that is needed to provide an automated compliance test facility. Advanced features such as pre-scanning, display of EUT status against applied field level and full Windows compatibility are standard. These synthesisers has been conceived with the practical user in mind. To make the best use of the immunity test facilities for both compliance testing and product investigations, several useful features have been developed. These include: Powerful EUT monitoring with real time display correlated to field strength and frequency. Sweep can be continuous or 'pause on fault' or 'stop on fault'. Additional EUT excitation output, either pulsed or continuous. Flexible single frequency search mode. Automatic ramping of field strength and fine control of frequency. >>>
    View the product on laplace.co.uk Laplace Instruments Ltd
    ULTRASONIC DIRECTIONAL MICROPHONE - INDIPOINT IDM 40

    ULTRASONIC DIRECTIONAL MICROPHONE - INDIPOINT IDM 40

    Ultrasonic Directional Microphone for the Location of Partial Discharges Brief Description Usable under live voltage conditions, no need to shut down Integrated laser pointer to mark the PD source Unaffected by interference Light and handy For indoor and outdoor use Simple to operate Uses rechargeable or non-rechargeable batteries Low current consumption, long battery life Robust transport case Additional red dot sight for use in very bright environment Application Partial discharges (PDs) are undesirable in medium- and high-voltage installations. They constitute a long term risk to effective insulation and thus also to operational reliability. However, detecting partial discharges without suitable instruments requires considerable experience and excellent powers of hearing. IndiPoint vastly simplifies the search for PD sources. It comprises a sharply focused ultrasonic microphone specially designed for use in electrical energy distribution installations. It is not necessary to shut down the installation before searching for faults. IndiPoint is suitable for use in both indoor and outdoor areas. Function Partial discharges give rise not only to electrical signals, but also to sounds in both the audible and ultrasonic range. These sound sources can be located to outstanding effect with a directional microphone. IndiPoint operates in the ultrasonic range where extraneous noise is scarcely encountered. IndiPoint comprises an ultrasonic microphone with an amplifier and headphones. By adjusting the amplification, the volume of weak PD sources can be increased and that of strong sources turned down. The large parabolic reflector sharply focuses the sound and allows the source to be identified with pinpoint accuracy. With the aid of the integrated laser pointer, the PD source can then be marked out for ease of location. For use in bright sunlight out of doors, IndiPoint is also equipped with a red dot sight as optical sighting device. The low current consumption of the amplifier enables the unit to operate for approx. 170 hours on one battery charge. Additional Uses IndiPoint is suitable not only for identifying partial discharges. It is also ideal for locating leaks, for example from pressurized pipes and tanks. Accessories IndiPoint is supplied complete with all accessories in a robust plastic transport case. Power is supplied by standard rechargeable batteries, so that in an emergency ordinary batteries (type AA) can be used instead. A quick-charger suitable for wide-range input is also included in the supply. Directional Microphone Casing Impact-resistant plastic Reflector diameter 277 mm Overall length 205 mm Weight Approx. 830 g (inc. rechargeable batteries) Range Up to 20 m Permissible ambient Operation: -10° ... 40° C temperature Storage: -20° ... 50° C Operating frequency 40 KHz Current consumption Approx. 10 mA Headphone connection 3.5 mm jack socket Battery compartment 4 x AA normal or rechargeable batteries Laser pointer As per EN 60825-1 Laser Class 2 P < 1mW, 650 nm Tripod thread 1/4 " Optical sighting red dot sight on top device Accessories Included Headphones Enclosed design 3.5 mm jack plug Weight approx. 270 g Batteries 4 x AA rechargeable NiMH batteries 1700 mAh Adequate for approx. 170 h continuous operation (without laser pointer) Charger Automatic quick-charger with compensation charging mode for 4 NiMH mignon cells Wide-range input 90 – 250 VAC, 50 - 60 Hz Power consumption max. 15VA Transport Case Dimensions 510 x 340 x 275 mm (L x B x H) Material Plastic Overall weight Approx. 7 Kg (with IDM 40 and all accessories) >>>
    View the product on may-elektronik.de May Elektronik




      Search    
     
     
     
    Search
    See all of the sector's products : Measuring devices, analysis and sensors