AC HIPOT TESTER - 1305

AC HIPOT TESTER - 1305

The 1305 is 3 KV, 5 mA AC Hipot tester. This entry-level tester is designed with the basic features for simple and cost-effective production line AC Hipot testing. It features a LED display, menu driven parameter control, pulse mode, parameter storage and continuous or momentary dwell cycles. 1. Tamper-Resistant Front Panel Design Prevents operators from inadvertently or accidentally modifying test parameters, and ensures consistent and reliable test results, minimizing the need for costly and time consuming product re-testing. 2. Simple Menu Control All parameters for the setups can be adjusted through a simple menu driven program. The easy to follow setup screens ensure that the operator correctly sets up all test parameters. 3. No load setup of trip current and output voltage This provides the operator with an easy and safe way to set trip currents and output voltages since parameters are set without the high voltage activated. 4. Test Storage The 1305 powers up with the parameters that were used during the last test to avoid operator setup errors. 5. LED Display With Meter Memory The 1305 features a LED display for setting up and viewing test results. The meter memory allows operators to review the last test results. 6. Software calibration control The 1305 is calibrated through the front panel keypad. All calibration information is stored in non-volatile memory. This allows the instrument to be completely calibrated without removing any covers and exposing the technician to hazardous voltages. 7. Line and load regulation This system maintains the output voltage to within 1% from no load to full load and over the line voltage range to ensure that test results remain consistent and within safety agency requirements. 8. Flashing high voltage indicator A flashing LED located directly over the high voltage terminal clearly indicates when high voltage is active to provide maximum operator safety. >>>
View the product on hipot.com Slaughter
BONDTESTING -  BONDASCOPE 300

BONDTESTING - BONDASCOPE 300

The All New BondaScope Series of Ultrasonic Bond Testers defines a new standard for ease of use, performance, features and portability in a Handheld Composite Bond Tester. The ALL NEW BondaScope 300 Bond Tester operates in a user selectable Tone Burst or Pulsed, Pitch-Catch mode with Pulse Rates up to 300Hz. Primary applications include impact damage assessment, skin-honeycomb, skin-skin composite, AL-AL Honeycomb and more. The BondaScope 300 will replace much more expensive bond testers available for many first and front line applications. >>>
View the product on advanced-ndt.co.uk Advanced NDT Limited
ELECTRONIC CONTROLS - HVAC

ELECTRONIC CONTROLS - HVAC

Ranco produces a wide range of electronic controls for a broad array of OEM (Original Equipment Manufacturer) HVAC applications. APPLICATIONS * The possibilities are almost limitless, but Ranco has designed and produced electronic controls for a number of different applications already, including: * Room Air Conditioners. * Packaged Terminal Air Conditioners (PTAC). * Humidifiers/Dehumidifiers. * Electronic Air Cleaners. * Heat Pump Defrost Controls. * Thermostats for a broad range of applications. >>>
View the product on icca.invensys.com/ranco/ran_prod_home.html Ranco Groupe - Invensys
ENERGY EFFICIENCY - VARMATIC LIGHTMASTER

ENERGY EFFICIENCY - VARMATIC LIGHTMASTER

The idea behind the Varmatic Lightmaster is simplicity itself. The amount of power actually required to supply most forms of lighting is less than what is actually drawn by the lights themselves. The Varmatic Lightmaster is designed to bridge this gap, and deliver significant energy cost savings on your lighting. The Varmatic Lightmaster has been developed after extensive research by our by our R&D department and incorporates specially designed electronic and electrical components which provide the optimum saving possible. >>>
View the product on sdcindustries.com/index.htm SDC Industries Ltd
AC HIPOT TESTER - 1340

AC HIPOT TESTER - 1340

The 1340 is a 2.5 KV, 40 mA AC Hipot tester designed for production line AC Hipot testing. With enough output for high capacity applications, the 1340 is ideal for hipot testing of manufactured and modular homes. With its advanced features and product reliability it is also well suited for quick and easy production line testing. 1. Tamper-Resistant Front Panel Design Prevents operators from inadvertently or accidentally modifying test parameters, and ensures consistent and reliable test results, minimizing the need for costly and time consuming product re-testing. 2. Simple Menu Control All parameters for the setups can be adjusted through a simple menu driven program. The easy to follow setup screens ensure that the operator correctly sets up all test parameters. 3. Electronic dwell settings The electronic dwell control helps keep test results consistent by ensuring that the test duration is the same for each product tested. 4. Electronic ramping Electronic ramping provides a gradual and timed method to increase output voltage to the DUT, minimizing any damage from quickly over-applying high voltage to sensitive DUTs. 5. No load setup of trip current and output voltage This provides the operator with an easy and safe way to set trip currents and output voltages since parameters are set without the high voltage activated. 6. Test Storage The 1340 powers up with the parameters that were used during the last test to avoid operator setup errors. 7. Optional Continuity test mode With this optional card, the 1340 meets ground continuity test requirements called out by UL and other safety agencies. 8. LED Display With Meter Memory The 1340 features a LED display for setting up and viewing test results. The meter memory allows operators to review the last test results. 9. Output voltage fine adjustment To make the 1340 usable in all types of applications, the operator can manually bring the voltage up or down in 10 volt increments by simply pressing the up and down arrow keys. This makes it very easy to adjust the output voltage even while the instrument is in the dwell mode so you can analyze test results at different voltages. 10. Software calibration control The 1340 is calibrated through the front panel keypad. All calibration information is stored in non-volatile memory. This allows the instrument to be completely calibrated without removing any covers and exposing the technician to hazardous voltages. 11. Line and load regulation This system maintains the output voltage to within 1% from no load to full load and over the line voltage range to ensure that test results remain consistent and within safety agency requirements. 12. PLC remote inputs and outputs The standard 9- pin interfaces provide outputs for Pass, Fail, and Test in Process. Inputs include Test, Reset and Interlock. This gives the user all the basic remotes required to configure the Hipot through simple PLC relay control. 13. Flashing high voltage indicator A flashing LED located directly over the high voltage terminal clearly indicates when high voltage is active to provide maximum operator safety. 14. Selectable Pulse Mode This user selectable mode allows the 1340 to provide 2.5 KV AC @ 10 mA of output voltage in short continuous intervals. It will automatically reset after a failure for continuous testing. While not an acceptable production line test, the pulse mode is very useful for troubleshooting the location of a failure as it continues to flash over at the failure point. >>>
View the product on hipot.com Slaughter
BONDTESTING - BONDASCOPE 3100

BONDTESTING - BONDASCOPE 3100

The New BondaScope Ultrasonic Bond Tester Series defines a new standard for ease of use, performance, features and portability in a Bond Tester.Advanced NDT Ltd. is proud to announce the release of the long awaited BondaScope 3100, Full Multi-Mode, Ultrasonic Bond Tester.The All New BondaScope 3100 Composite Bond Tester is the latest in a full series of Affordable, Feature Rich, and High Performance Ultrasonic Bond Testers available from Advanced NDT Limited, the originators of the first Microprocessor Based, Impedance Plane Resonance Bond Tester. >>>
View the product on advanced-ndt.co.uk Advanced NDT Limited
AC/DC HIPOT TESTER  - 2550

AC/DC HIPOT TESTER - 2550

The 2550 provides both AC Hipot and DC Hipot testing in a single instrument. It features a 5 KV, 10 mA AC Hipot test and a 5 KV 3 mA DC Hipot test. With its advanced features and product reliability it is well suited for quick and easy Electrical Safety testing. 1. Tamper-Resistant Front Panel Design Prevents operators from inadvertently or accidentally modifying test parameters, and ensures consistent and reliable test results, minimizing the need for costly and time consuming product re-testing. 2. Simple Menu Control All parameters for the setups can be adjusted through a simple menu driven program. The easy to follow setup screens ensure that the operator correctly sets up all test parameters. 3. Electronic dwell settings The electronic dwell control helps keep test results consistent by ensuring that the test duration is the same for each product tested. 4. Electronic ramping Electronic ramping provides a gradual and timed method to increase output voltage to the DUT, minimizing any damage from quickly over-applying high voltage to sensitive DUTs. 5. No load setup of trip current and output voltage This provides the operator with an easy and safe way to set trip currents and output voltages since parameters are set without the high voltage activated. 6. Test Storage The 2550 powers up with the parameters that were used during the last test to avoid operator setup errors. 7. Optional Continuity test mode With this optional card, the 2550 meets ground continuity test requirements called out by UL and other safety agencies. 8. LED Display With Meter Memory The 2550 features a LED display for setting up and viewing test results. The meter memory allows operators to review the last test results. 9. Output voltage fine adjustment To make the 2550 usable in all types of applications, the operator can manually bring the voltage up or down in 10 volt increments by simply pressing the up and down arrow keys. This makes it very easy to adjust the output voltage even while the instrument is in the dwell mode so you can analyze test results at different voltages. 10. Software calibration control The 2550 is calibrated through the front panel keypad. All calibration information is stored in non-volatile memory. This allows the instrument to be completely calibrated without removing any covers and exposing the technician to hazardous voltages. 11. Line and load regulation This system maintains the output voltage to within 1% from no load to full load and over the line voltage range to ensure that test results remain consistent and within safety agency requirements. 12. PLC remote inputs and outputs The standard 9- pin interfaces provide outputs for Pass, Fail, and Test in Process. Inputs include Test, Reset and Interlock. This gives the user all the basic remotes required to configure the Hipot through simple PLC relay control. 13. Flashing high voltage indicator A flashing LED located directly over the high voltage terminal clearly indicates when high voltage is active to provide maximum operator safety. >>>
View the product on hipot.com Slaughter
AC/DC HIPOT TESTER - 2935

AC/DC HIPOT TESTER - 2935

The 2935 allows manufacturers to perform AC Hipot, and DC Hipot tests in a single instrument. This Electrical Safety Tester features a 5 KV AC Hipot test with 12 mA of test current and a 6 KV DC Hipot test with 5 mA of test current. Equipped with the latest technology and features the 2935 is the right solution for a Electrical Safety testing applications that require both AC and DC Hipot test voltage. 1. Tamper proof front panel controls This makes it possible to limit user access to the setup screens so that only authorized personnel can change test parameters. 2. Test setup memories The operator can store and recall test setups, thus eliminating the need to re-enter setup information. There are five memory locations available. 3. Low-current sense The low current sense feature monitors the minimum level of current flow, thus ensuring that the DUT is properly connected and that the Hipot test is being performed. 4. Simple Menu Control All parameters for the setups can be adjusted through a simple menu driven program. The easy to follow setup screens ensure that the operator correctly sets up all test parameters. 5. Electronic dwell settings The electronic dwell control helps keep test results consistent by ensuring that the test duration is the same for each product tested. 6. Electronic ramping Electronic ramping provides a gradual and timed method to increase output voltage to the DUT, minimizing any damage from quickly over-applying high voltage to sensitive DUTs. 7. Front panel LCD A front panel LCD allows the operator to monitor the test. The display holds the results after a test item failure so that the operator can easily review the test results. Indications of high fail and continuity failure are clearly displayed. 8. No load setup of trip current and output voltage This provides the operator with an easy and safe way to set trip currents and output voltages since parameters are set without the high voltage present. 9. Storage of test program The 2935 powers-up with the same parameters that were used during the last test to avoid operator set-up errors. 10. Built-in Continuity test mode The 2935 meets ground continuity test requirements called out by UL and other safety agencies. 11. Output voltage fine adjustment To make the 2935 usable in all types of applications, the operator can manually bring the voltage up or down in 10 volt increments by simply pressing the up and down arrow keys. This makes it very easy to adjust the output voltage even while the instrument is in the dwell mode so you can analyze test results at different voltages. 12. Software calibration control The 2935 is calibrated through the front panel keypad. All calibration information is stored in non-volatile memory. This allows the instrument to be completely calibrated without removing any covers and exposing the technician to hazardous voltages. 13. Current monitoring The LCD display allows monitoring of current down to 100 microamps AC and 20 microamps DC. This allows the 2935 to be used even when test requirements only allow a very low level of acceptable leakage current. 14. Line and load regulation This system maintains the output voltage to within 1% from no load to full load and over the line voltage range to ensure that test results remain consistent and within safety agency requirements. 15. PLC remote inputs and outputs The standard 9- pin interfaces provide outputs for Pass, Fail, and Test in Process. Inputs include Test and Reset. This gives the user all the basic remotes required to configure the Hipot through simple PLC relay control. 16. Flashing high voltage indicator A flashing LED located directly over the high voltage terminal clearly indicates when high voltage is active to provide maximum operator safety. >>>
View the product on hipot.com Slaughter
AC/DC/IR HIPOT TESTER - 2945

AC/DC/IR HIPOT TESTER - 2945

The 2945 allows manufacturers to perform AC Hipot, DC Hipot and Insulation Resistance tests in a single instrument. The 2945 features a 5 KV AC Hipot test with 12 mA of test current, a 6 KV DV Hipot test with 5 mA of test current and a Insulation Resistance test with a test range of up-to 1000 MO. Equipped with the latest technology and features this Electrical Safety Tester is the right solution for a variety of Hipot test applications. 1. Tamper proof front panel controls This makes it possible to limit user access to the setup screens so that only authorized personnel can change test parameters. 2. Test setup memories The operator can store and recall test setups, thus eliminating the need to re-enter setup information. There are five memory locations available. 3. Low-current sense The low current sense feature monitors the minimum level of current flow, thus ensuring that the DUT is properly connected and that the Hipot test is being performed. 4. Simple Menu Control All parameters for the setups can be adjusted through a simple menu driven program. The easy to follow setup screens ensure that the operator correctly sets up all test parameters. 5. Electronic dwell settings The electronic dwell control helps keep test results consistent by ensuring that the test duration is the same for each product tested. 6. Electronic ramping Electronic ramping provides a gradual and timed method to increase output voltage to the DUT, minimizing any damage from quickly over-applying high voltage to sensitive DUTs. 7. Front panel LCD A front panel LCD allows the operator to monitor the test. The display holds the results after a test item failure so that the operator can easily review the test results. Indications of high fail and continuity failure are clearly displayed. 8. No load setup of trip current and output voltage This provides the operator with an easy and safe way to set trip currents and output voltages since parameters are set without the high voltage present. 9. Storage of test program The 2945 powers-up with the same parameters that were used during the last test to avoid operator set-up errors. 10. Built-in Continuity test mode The 2945 meets ground continuity test requirements called out by UL and other safety agencies. 11. Output voltage fine adjustment To make the 2945 usable in all types of applications, the operator can manually bring the voltage up or down in 10 volt increments by simply pressing the up and down arrow keys. This makes it very easy to adjust the output voltage even while the instrument is in the dwell mode so you can analyze test results at different voltages. 12. Software calibration control The 2945 is calibrated through the front panel keypad. All calibration information is stored in non-volatile memory. This allows the instrument to be completely calibrated without removing any covers and exposing the technician to hazardous voltages. 13. Current monitoring The LCD display allows monitoring of current down to 100 microamps AC and 20 microamps DC. This allows the 2945 to be used even when test requirements only allow a very low level of acceptable leakage current. 14. Line and load regulation This system maintains the output voltage to within 1% from no load to full load and over the line voltage range to ensure that test results remain consistent and within safety agency requirements. 15. PLC remote inputs and outputs The standard 9- pin interfaces provide outputs for Pass, Fail, and Test in Process. Inputs include Test and Reset. This gives the user all the basic remotes required to configure the Hipot through simple PLC relay control. 16. Flashing high voltage indicator A flashing LED located directly over the high voltage terminal clearly indicates when high voltage is active to provide maximum operator safety. >>>
View the product on hipot.com Slaughter
AMP GROUND BOND TESTER - 2630 30

AMP GROUND BOND TESTER - 2630 30

Featuring 30 Amps of Ground Bond test current, the 2630 is designed for stand alone Ground Bond test applications or as a companion instrument to our Hipot testers. It has the capability to interconnect with all of our Hipot testers for same station Electrical Safety testing application. Equipped with the latest technology and features it is a perfect solution for production line Ground Bond testing. 1. Tamper proof front panel controls This makes it possible to limit user access to the setup screens so that only authorized personnel can change test parameters. 2. Test setup memories The operator can store and recall five test setups, thus eliminating the need to re-enter setup information. 3. Simple menu control All parameters for the setups can be adjusted through a simple menu driven program. The easy to follow setup screens ensure that the operator correctly sets up all test parameters. 4. Electronic dwell setting Fully adjustable electronic dwell control helps keep test results consistent by ensuring that the test duration is the same for each product tested. 5. Milliohm offset capability This function allows the use of longer test leads and test fixtures without compromising the test results. 6. Front Panel LCD A front panel LCD allows the operator to monitor the test. The display holds the results after a test item failure so that the operator can easily review the test results. 7. Adjustable output current and milliohm trip ranges This capability makes the 2630 versatile enough to meet all safety agency specifications for ground bond test requirements. 8. PLC remote inputs and outputs The standard 9 pin interfaces provide outputs for Pass, Fail, and Test in Process, Start Out and Reset Out. Inputs include Test, Reset, and Withstand Processing. 9. Software calibration control The 2630 is calibrated through the front panel keypad. All calibration information is stored in a non-volatile memory. This allows the instrument to be completely calibrated without removing any covers. 10. Test Indicator An LED located directly over the high current terminal clearly indicates when high current is active to provide maximum operator safety. 11. Withstand processing indicator The front panel display indicates when the high voltage from a Hipot is being applied to the Device Under Test (DUT) for greater operator safety. 12. Interconnection capability The 2630, through a versatile PLC control, can be interconnected to any one of Slaughter’s Hipot testers. This provides manufacturers a test system that can combine both Hipot and Ground Bond tests. >>>
View the product on hipot.com Slaughter
DC HIPOT TESTER - 2503

DC HIPOT TESTER - 2503

The 2503 is a 5 KV, 3 mA DC Hipot tester that is designed for production line DC Hipot testing applications. With its advanced features and product reliability it is well suited for quick and easy production line safety testing. 1. Tamper-Resistant Front Panel Design Prevents operators from inadvertently or accidentally modifying test parameters, and ensures consistent and reliable test results, minimizing the need for costly and time consuming product re-testing. 2. Simple Menu Control All parameters for the setups can be adjusted through a simple menu driven program. The easy to follow setup screens ensure that the operator correctly sets up all test parameters. 3. Electronic dwell settings The electronic dwell control helps keep test results consistent by ensuring that the test duration is the same for each product tested. 4. Electronic ramping Electronic ramping provides a gradual and timed method to increase output voltage to the DUT, minimizing any damage from quickly over-applying high voltage to sensitive DUTs. 5. No load setup of trip current and output voltage This provides the operator with an easy and safe way to set trip currents and output voltages since parameters are set without the high voltage activated. 6. Test Storage The 2503 powers up with the parameters that were used during the last test to avoid operator setup errors. 7. Optional Continuity test mode With this optional card, the 2503 meets ground continuity test requirements called out by UL and other safety agencies. 8. LED Display With Meter Memory The 2503 features a LED display for setting up and viewing test results. The meter memory allows operators to review the last test results. 9. Output voltage fine adjustment To make the 2503 usable in all types of applications, the operator can manually bring the voltage up or down in 10 volt increments by simply pressing the up and down arrow keys. This makes it very easy to adjust the output voltage even while the instrument is in the dwell mode so you can analyze test results at different voltages. 10. Software calibration control The 2503 is calibrated through the front panel keypad. All calibration information is stored in non-volatile memory. This allows the instrument to be completely calibrated without removing any covers and exposing the technician to hazardous voltages. 11. Line and load regulation This system maintains the output voltage to within 1% from no load to full load and over the line voltage range to ensure that test results remain consistent and within safety agency requirements. 12. PLC remote inputs and outputs The standard 9- pin interfaces provide outputs for Pass, Fail, and Test in Process. Inputs include Test, Reset and Interlock. This gives the user all the basic remotes required to configure the Hipot through simple PLC relay control. 13. Flashing high voltage indicator A flashing LED located directly over the high voltage terminal clearly indicates when high voltage is active to provide maximum operator safety. >>>
View the product on hipot.com Slaughter
MULTI-FUNCTION ELECTRICAL SAFETY TESTER - 4320

MULTI-FUNCTION ELECTRICAL SAFETY TESTER - 4320

The 4320 allows manufacturers to perform AC Hipot, DC Hipot, Insulation Resistance and Ground Bond tests in a single instrument. The 4320 offers incredible value if you want to perform multiple electrical safety tests in a single instrument. Test functionality includes a 5 KV, 20 mA AC Hipot, 6 KV, 5 mA DC Hipot, Insulation Resistance and a 30 Amp Ground Bond. Equipped with the latest technology and features the 4320 is the right solution for a variety of electrical safety testing applications. 1. Tamper proof front panel controls This makes it possible to limit user access to the setup screens so that only authorized personnel can change test parameters. 2. Multiple Test Memories The 4320 provides six test memories with six steps per memory. This is beneficial for manufacturers testing multiple products on one production line. 3. Low-current sense The low current sense feature monitors the minimum level of current flow, thus ensuring that the DUT is properly connected and that the Hipot test is being performed. 4. Simple Menu Control All parameters for the setups can be adjusted through a simple menu driven program. The easy to follow setup screens ensure that the operator correctly sets up all test parameters. 5. Electronic dwell settings The electronic dwell control helps keep test results consistent by ensuring that the test duration is the same for each product tested. 6. Electronic ramping Electronic ramping provides a gradual and timed method to increase output voltage to the DUT, minimizing any damage from quickly over-applying high voltage to sensitive DUTs. 7. Front panel LCD A front panel LCD allows the operator to monitor the test. The display holds the results after a test item failure so that the operator can easily review the test results. Failure indications are clearly displayed. 8. No load setup of trip current and output voltage This provides the operator with an easy and safe way to set trip currents and output voltages since parameters are set without the high voltage present. 9. Storage of test program The 4320 powers-up with the same parameters that were used during the last test to avoid operator set-up errors. 10. Output voltage fine adjustment To make the 4320 usable in all types of applications, the operator can manually bring the voltage up or down in 10 volt increments by simply pressing the up and down arrow keys. This makes it very easy to adjust the output voltage even while the instrument is in the dwell mode so you can analyze test results at different voltages. 11. Software calibration control The 4320 is calibrated through the front panel keypad. All calibration information is stored in non-volatile memory. This allows the instrument to be completely calibrated without removing any covers and exposing the technician to hazardous voltages. 12. Current monitoring The LCD display allows monitoring of current down to 10 microamps AC and 10 microamps DC. This allows the 4320 to be used even when test requirements only allow a very low level of acceptable leakage current. 13. Line and load regulation This system maintains the output voltage to within 1% from no load to full load and over the line voltage range to ensure that test results remain consistent and within safety agency requirements. 14. PLC remote inputs and outputs The standard 9- pin interfaces provide outputs for Pass, Fail, and Test in Process. Inputs include Test, Reset, Interlock, and Memory Recall. This gives the user all the basic remotes required to configure the Hipot through simple PLC relay control. 15. Flashing high voltage indicator A flashing LED located directly over the high voltage terminal clearly indicates when high voltage is active to provide maximum operator safety. 16. Single Step Test Mode In this mode, the 4320 can be configured to perform each test individually as a single step. This provides the manufacturers flexibility in configuring their testing procedure. >>>
View the product on hipot.com Slaughter
MULTI-FUNCTION ELECTRICAL SAFETY TESTER - 6330

MULTI-FUNCTION ELECTRICAL SAFETY TESTER - 6330

The 6330 allows manufacturers to perform six of the most common electrical safety tests in a single instrument. This 6-in-1 Electrical Safety tester will perform AC Hipot, DC Hipot, Insulation Resistance, Ground Bond, Functional Run, and Line Leakage Tests in a single instrument. Equipped with the latest technology and features at a cost-effective price, the 6330 is a good solution for applications requiring multiple safety tests. 1. Six tests in one instrument New 6-in-1 design allows manufacturers to cost-effectively perform multiple electrical safety tests in a single instrument. The 6330 will perform AC Hipot, DC Hipot, Insulation Resistance, Ground Bond, Functional Run, and Line Leakage Tests. 2. Line Leakage test mode The 6330 provides 5 different measuring devices built in allowing for Line Leakage testing to common agency specifications. 3. Functional Run test mode The 6330 can monitor minimum and maximum readings for Voltage, Current, Power, Power Factor, and Leakage Current. 4. Multiple test memories The 6330 provides 10 memories with 20 steps per memory. It is possible to program multiple testing procedures and store them in the instrument's internal memory. This is beneficial for manufactures that test multiple products on one manufactured line. 5. Simple menu control All parameters for the setups can be adjusted through a simple menu driven program. The easy to follow setup screens ensure that the operator correctly sets up all test parameters. 6. PLC remote inputs and outputs The standard 9-pin interfaces provide outputs for Pass, Fail, and Test in Process. Inputs include Test, Reset, Interlock, and Memory Recall 1-6. This gives the user all the basic remotes required to configure the tester through simple PLC relay control. 7. Electronic dwell settings Electronic dwell control helps keep test results consistent by ensuring that the test duration is the same for each product tested. 8. Electronic ramping Electronic ramping provides a gradual and time method to increase output voltage to the DUT, minimizing any damage from quickly over-applying high voltage to sensitive DUT’s. 9. Tamper proof front panel controls This makes it possible to limit user access to the setup screens so that only authorized personnel can change test parameters. 10. No load setup of trip current and output voltage This provides the operator with an easy and safe way to set trip currents and output voltages since parameters are set without the high voltage present. 11. Software calibration control The 6330 is calibrated through the front panel keypad. All calibration information is stored in non-volatile memory. This allows the instrument to be completely calibrated without removing any covers and exposing the technician to hazardous voltages. 12. Line and load regulation This tester maintains the output voltage to within 1% from no load to full load and over the line voltage range to ensure that test results remain consistent and within safety agency requirements. 13. Single step test mode In this mode, the 6330 can be configured to perform each test individually as a single step. This provides the manufacturers flexibility in configuring their testing procedure. 14. Milliohm offset capability Milliohm offset minimizes the effect of test lead or test fixture resistance in Ground Bond testing. 15. Fail stop ON/OFF mode This allows the 6330 to be configured to continue testing after detecting a failure. All pass/fail results are displayed at the complete of the test cycle. 16. Flashing high voltage indicator A flashing LED located directly over the high voltage terminal clearly indicates when high voltage is active to provide maximum operator safety. 17. Low current sense The low current sense feature monitors the minimum level of current flow, thus ensuring that the DUT is properly connected and that the Hipot test is being performed. >>>
View the product on hipot.com Slaughter