Displays: suppliers, wholesalers and manufacturers on Hellopro
Search   
Buscar entre los 9 857 Proveedores y 101 655 Productos


Displays :

50 products
Selection of 40 products among 50
GRAPHIC DISPLAY

GRAPHIC DISPLAY

The display has a large viewing area of 128 x 64 pixels, measuring 60 by 30 mm, that allows a maximum of 160 characters to be displayed ( eight rows of 20 characters). There is also the option for two different font sizes so that larger characters can be displayed. The two font sizes can be used separately or together. Both text and symbols can be displayed and is compliant with standard and extended ASCII. >>>
View the product on datek.net Datek
MINEWATCH PC21-2D DISPLAY MODULE

MINEWATCH PC21-2D DISPLAY MODULE

The PC 21 2D Module provides the user interface, it is equipped with a 16 line 21 character LCD display and a 4 x 4 keypad. The keypad enables navigation of various displays to interrogate the module and the cluster to which it is connected. The MineWATCH PC 21-2D has eight switch inputs intended for start and stop buttons etc. In common with other MineWATCH PC 21 modules, the PC 21-2D module is powered from a 12 volt dc intrinsically safe power supply. This can be a separate power supply, or from a common power supply feeding several modules via the cluster CAN bus. >>>
View the product on davisderby.co.uk Davis Derby Ltd
DISPLAY MONITOR - MODEL VM500

DISPLAY MONITOR - MODEL VM500

Features Versatile acceleration, velocity, displacement or temperature monitor Interface with accelerometer, proximity probe or "J" type thermocouple Two programmable alarm levels with delay on make/break relays 4-20 mA fully scalable output for interface with PLC, DCS, alarm and SCADA systems RMS (standard) or peak readings Small NEMA 4, 1/8 DIN package High/low pass filters available Adjustable sampling time Signal output: raw, filtered, rep. DC value Applications Any application where immediate display of machine PdM data or 4-20 mA output is required Operating Specifications Dynamic Accuracy ±5% Acceleration 3 Hz - 2 kHz Velocity 3 Hz - 2 kHz Displacement 6 Hz - 2 kHz Optional Filtering High Pass: 3, 5, 10, 20, 50, 100, 200, 500, 5k Hz Low Pass: none, 50, 70, 100, 200, 500, 1k, 2k Hz Accelerometer Input, mV/g 100 (standard) 10 or 500 Electrical Power Requirements, Auto-sensing AC-DC 85-265 VAC, 95-370 VDC (standard) 15-48 VAC, 10-72 VDC Relays (2) Form C Environmental Operating Temperature Range 32°F to 140°F / 0°C to 60°C Acceleration Limit 20 g Velocity Limit 20 ips Displacement Limit 200 mils Temperature Limit 1400°F / 760°C Physical Display .56 inch bright red LED Weight 6.5 ounces / 184 grams Front Panel NEMA 4 >>>
View the product on vibrametrics.com VibraŔMetrics Groupe - MISTRAS Holding
AIR DATA DISPLAY - AD32 RVSM

AIR DATA DISPLAY - AD32 RVSM

Options * Solid-state pressure sensors * RVSM compliant * Static Source Error Correction * Integrated Altitude Alerter * English/metric scale setting * Standby/Normal operation * Baro Push-to-Reset function * Push-to-Test and continuous Built-In-Test * BIT Failure memory * Display with LCD / stepper motor drive pointer * ARINC 408, 3ATI, with IMI ring pointers * RS232 Maintenance Interface >>>
View the product on thommenag.ch THOMMEN
FETALGARD LITE

FETALGARD LITE

Analogic’s FETALGARD® Lite antepartum fetal monitors provide clinicians, birthing centers, and hospitals with the features they require, while maintaining unsurpassed accuracy and reliability at very competitive prices. The FETALGARD Lite offers tremendous value in a rugged, compact, and lightweight unit. Features include: Unique, Non Stress Test (NST) graticule indicator Back-lit LCD screen Trace scroll Battery / optional AC operation Transducer-based signal indicator Single or twins ultrasound Advanced patient data storage Light and portable Communications with a computer/network Programmable alarms Optional recorder >>>
View the product on analogic.com ANALOGIC
1005 ANALOGUE INDICATOR, SINGLE INPUT.

1005 ANALOGUE INDICATOR, SINGLE INPUT.

Designed, produced and serviced by us to meet the needs of the manual gauging market, this rugged instrument of advanced design is flexible, versatile, fast, accurate and easy to use. With analogue meter, this unit makes manual gauging simple. Very rugged it's construction makes an ideal solution for many industries.With rapid response, high accuracy and good resolution. Amber, red, and green tolerance lights indicate above below and within tolerance limits.It will connect to bore, snap, and many measuring stand type gauges >>>
View the product on alphagauging.com Alpha Gauging Ltd
FIBRE OPTIC COLD LIGHT SOURCE KL200

FIBRE OPTIC COLD LIGHT SOURCE KL200

SCHOTT KL 200, 20-W light source for use with fiber optic bundles, ringlights and goosenecks in microscopy applications. The brightness of the KL200 can be controlled in three stages. At stage one, the light reflector bulb provides a service life of 10,000 h, while stage three offers 300 h and a color temperature of 3200 K. The light source interrupts the electrical supply when the bulb compartment is opened. No fan is required, resulting in vibration-free operation. >>>
View the product on galvoptics.fsnet.co.uk Galvoptics
PEARSON CLAMP-ON CURRENT MONITOR

PEARSON CLAMP-ON CURRENT MONITOR

The Pearson Clamp-on Current Monitor facilitates measurement of current without opening the circuit. There are two different designs. One consists of two parts that may be separated to allow clamping around the conductor to be monitored. The other with a hinged type opening. The Pearson Clamp-on Current Monitor is designed to maintain its wide bandwidth and accuracy. Clamp-on's with apertures from 1/2 inch to 18 inches have been manufactured with certain models in stock and available for immediate delivery >>>
View the product on pearsonelectronics.com Pearson Electronics
CONTROL UNITS

CONTROL UNITS

Control units are switching devices which close or open electrical circuits. A control unit is a combination of an actuator and a contact block. The various product ranges are supplemented with signal indicators, which consist of a signal indicator element and a lamp socket. RAFIX 16, mounting hole diameter 16,2 mm RAFIX 16 F, monting hole diameter 16,2 mm, extremely low profile RAFIX 22 QR, mounting hole diameter 22,3 mm RAFIX 22 FS, mounting hole diameter 22,3 mm, mounting depth only 9,2 mm >>>
View the product on rafi-france.fr Rafi France
CONTROLLERS LCD

CONTROLLERS LCD

Digital View is the leading supplier of LCD interface solutions for application specific OEM display products. Suitable for project design-in Industrial standard components chosen for high MTBF View products Extensive range of standard features Highly flexible panel support Comprehensive OSD control Customisation for specific application requirements Cost effective global organization with volume manufacturing in Asia >>>
View the product on digitalview.com Digital View
LCD MODULES - B/W AND COLOR

LCD MODULES - B/W AND COLOR

EM produces Customer Specific & Standard LCD Modules (monochrome and full color) for a diverse range of applications using a variety of different LCD and assembly technologies. TN, STN, FSTN Technologies ¦ For segmented or alphanumeric / graphic displays ¦ TN with colour segments and background other than B/W CSTN, TFT technologies ¦ For graphic displays up to 5'' diagonal size Glass substrate of 0.3mm, but also 0.55, 0.7 and 1.1mm ¦ Thin glass gives the final product slimmer profile and better viewability. EM produces LCDs with 2 x 0.3mm glass compared to the industry standard of 2 x 0.55, 0.7 and 1.1mm glass, which may be too thick for many applications. Special technologies ¦ Gluing LCDs together with high optical characteristics Shaped LCDs EM LCDs are not bound to the traditionnal rectangular shape. They can be delivered in several shapes ideally tailored to the space or design requirements of the customer's product. Sometimes, rectangular LCDs consume to much space or surface; custom shaped LCD offer an elegant alternative. EM has developed manufacturing techniques which allow the production of glass LCDs in several shapes. Holes Some applications require a pass through in the LCD glass for mechanical and electrical connections. EM is able to make holes in the LCD glass itself. Customer specific Most of EM's LCD products are customer specific designs. EM is used to accomodate to the particular requests and to engineer solutions, which optimally fit the customer's requirements. For TFT solutions, the customization is performed around standard TFT panels. Standard modules ¦ Standard modules are available. Please refer to related Factsheets on the bottom part of this page. Assembly technologies ¦ COB, Chip-on-Board technology ¦ COG, Chip-on-Glass technology ¦ COF, Chip-on-Film technology ¦ With integrated back-light or light-guide ¦ With EM or any other IC driver (LCD Drivers or microcontrollers) ¦ Subassembly into custom-injected plastic parts Light-guides ¦ Back-light (LED, CCFL, EL) or Light-guide features can be integrated in the LCD Module. Touch screens ¦ LCD Modules can be integrated with several types of touch screens (resistive, capacitive,…etc). Typical lead times for a new LCD module ¦ 2 weeks to get the counter drawings ¦ 5 to 10 weeks to get the samples after drawing approval ¦ 6 to 12 weeks to get the first production after sample approval >>>
View the product on emmicroelectronic.com EM marin
LIGHTING CONTROL PANELS - ILIGHT

LIGHTING CONTROL PANELS - ILIGHT

ILight is introducing a new range of lighting control panels at the Integrated Systems Europe 2007 exhibition. The rear of the panels is shaped to fit the German style round back boxes commonly fitted in continental Europe. These panels mean that installers in Europe can save time and effort since they won't have to replace existing back boxes, said Peter van der Kolk, iLight's European business development manager. They also overcome the problem of sourcing UK back boxes on the continent. The European panels also have another innovation. The LEDs incorporated in the panels can be dimmed if required, which can be an advantage when used in a dark environment such as a bedroom. The panels' functions are the same as for iLight's other panel ranges. They include up to 20 configurable internally illuminated push buttons on a double gang panel and 10 on a single gang unit. They are fully configurable, including room joining, sequencing and programmable logic functions. The European panels are available in 15 different finishes, with colour coordinated push button caps and integral blue LED indicators. iLight is also introducing an architrave control panel at Integrated Systems Europe. This thin and stylish panel, with its own back box, is designed to be mounted in narrow spaces such as in a door frame. Available with up to seven buttons, it also features dimmable LEDs, and comes in a choice of attractive finishes. >>>
View the product on mondoarc.com MONDO*ARC MEDIA
FETALGARD LITE WITH NIBP

FETALGARD LITE WITH NIBP

The FETALGARD Lite with NIBP offers tremendous value in a rugged, compact, and lightweight unit that provides the maternal blood pressure and heart rate measurements that are critical to managing the birthing process. The FETALGARD Lite with NIBP, which includes extensive connectivity and interface capabilities, also features: Display and date stamp of maternal blood pressure Manual, automatic and stat blood pressure modes Indicator for elapsed time since last measurement The FETALGARD Lite with NIBP, and the standard FETALGARD Lite both feature: Unique, Non Stress Test (NST) graticule indicator Back-lit LCD screen Trace scroll Battery / optional AC operation Transducer-based signal indicator Single or twins ultrasound Advanced patient data storage Light and portable Can communicate with a computer/network Programmable alarms Optional recorder >>>
View the product on analogic.com ANALOGIC
3005 COLUMN INDICATOR, SINGLE INPUT.

3005 COLUMN INDICATOR, SINGLE INPUT.

Measurement Indication: 100 Segment displayProbe Input: 1 x 5 pin 240ş Din half bridge. (see options)Accuracy: 1% of selected range.Drift: 3% within 30 minutes of switch on, long-term negligible.Zero Adjustment: 10 turn ± 125µm on all ranges.Probe Calibration Adjustment: 10% on highest range.Power supply in: 230 volt AC. or 110 volt AC.Power supply out: "pigtail" interlinking cable.Dimensions: 45mm x 120mm x 385mm.Weight: 2 Kgs. >>>
View the product on alphagauging.com Alpha Gauging Ltd
DELTA® MIT OPTODRIVE® OPTODRIVE®

DELTA® MIT OPTODRIVE® OPTODRIVE®

The drive's integrated injection control ensures that the required dosing quantity actually reaches the process – and does this without the use of separate accessoriesThe integrated injection control detects blocked dosing points or fractured dosing lines. This protects the environment from damage resulting from continued dosing with a fractured lineAir or gases trapped in the dosing head ("air-lock") are also detected, thus preventing incorrect quantities being dosed >>>
View the product on prominent.co.uk ProMinent Fluid Controls
FIBRE OPTIC COLD LIGHT SOURCE KL2500

FIBRE OPTIC COLD LIGHT SOURCE KL2500

SCHOTT KL 2500 LCDPerformance leader in AC light sources. Twice the amount of light given out by the Schott KL 1500 LCD.Easy of use, it is supplied with a filter wheel, which accommodates up to five insert filters. Filter selection is as simple as a turn of the knobElectronic accessories, such as remote control, RS-232 or tilt switch, can be connected to the front panel of the device enabling light source operation in difficult access areasWith the modified collet chuck, light guides up to 15-mm fiber bundle diameter can be used with optimum results. >>>
View the product on galvoptics.fsnet.co.uk Galvoptics
HEMODYNAMIC STATUS MONITOR LIFEGARD ICG

HEMODYNAMIC STATUS MONITOR LIFEGARD ICG

The LIFEGARD ICG employs Impedance CardioGraphy (ICG), the new standard for the non-invasive assessment of a patient’s hemodynamic condition. LIFEGARD ICG measures cardiac output and displays 17 other derived hemodynamic parameters as well as non-invasive blood pressure, heart rate, and 2 waveforms. The monitors feature a color, active-matrix screen (5 inches) for crisp, bright, easy-to-read numerics visible from virtually anywhere in the room. The LIFEGARD ICG also Provides: A unique “Signal Quality Indicator” (SQI) to allow visual confirmation of signal integrity Multiple display modes – main display, all data, tabular trend, graphical trend, and more Color-coded tabular and graphical trends that match measured parameters 3 blood pressure measurement modes: manual, automatic, and STAT, supported by an indicator for elapsed time since last measurement. Operation is very intuitive. The LIFEGARD navigation knob and function keys make it easy to use, requiring minimal training. Patient documentation is quickly accessible. All LIFEGARD monitors have an integrated strip chart printer for quick, complete documentation with time, date, and all numeric values. Convenient to use, all LIFEGARD ICG monitors are battery operated so they can easily be carried anywhere. Custom roll stands are available for convenient movement between rooms and from bedside to bedside. Every Analogic LIFEGARD Family patient monitor is backed by a full two-year warranty on all parts and service. A customer service hotline allows immediate contact with the manufacturer should a problem arise. >>>
View the product on analogic.com ANALOGIC
C100 MICRO PROCESSOR BASED COLUMNS

C100 MICRO PROCESSOR BASED COLUMNS

The column gauge C100 is an electronic gauge supporting 4 inductive transducers (probes), pneumatic converters or sensors with analogue voltage output signals. There are three different types to this column, they are 1. Dynamic Version, giving static and dynamic measurements for up to 4x transducers. Dynamic mode gives the following functions i.e. Min - Max - TIR - or Mean display readings.2. Multi Gauging Version, giving manual and automatic selection of 1 - 4 gauges, i.e. 4 x column gauges in one.3. Grading Version, giving classification of components in up to 30 classes. >>>
View the product on alphagauging.com Alpha Gauging Ltd
DULCOMARIN® II COMPACT

DULCOMARIN® II COMPACT

The DULCOMARIN® II compact is the optimum solution for private swimming pools. Easy to operate, easy to install and with all the luxuries of the new DULCOMARIN ® II generation.Integrated videographic recorder – saves on investment in a printer, ink and paper.Measurement of combined chlorineSystems control e.g. UV for reducing the combined chlorine componentLarge 1/4 VGA colour display >>>
View the product on prominent.co.uk ProMinent Fluid Controls
MICRO WOP-IT PANEL

MICRO WOP-IT PANEL

Technical datasTechnical datasFrontpanel STN-Display 5,7", 320 x 240 Pixel Color (65536 Colors) or Monochrome (256 Grayscales) Input Resistive Touch Protection type IP 65 front side by DIN EN60529 Electricity supply Operation value 24 V ± 20%, polarised Current consumption approx. 0,5 A System Processor Intel PXA255 (ARM), 400 MHz internal main memory 64 MB SDRAM external memory medium 64 MB Compact Flash Card (maximum 1 GB) Operating system VxWorks Interfaces Serial 1 RS232 free for disposal Serial 2 for Bus systems and PLC coupling (e. g. MPI, Profibus, CAN, ...) LAN Ethernet 10/100 Mbps USB not supported under WOP-iT General Front material Aluminium Foil acid-resistant polyester foil Outer dimensions (B x H x T) 215 x 160 x 53 mm Mounting dimensions (B x H) 197 x 143 mm Weight approx. 1 kg Temperature Operation: 0 ... 50° C Storage: -20 ... 60° C >>>
View the product on lauer-systeme.net Elektronik Systeme Lauer
PORTABLE PATIENT MONITORS LIFEGARD I

PORTABLE PATIENT MONITORS LIFEGARD I

LIFEGARD® I Patient Monitors are very affordable, compact, general-purpose devices, optimized for low-acuity care areas and patient transport. Simple to use and easy to read, they feature a 5-inch color screen for crisp, bright easy-to-read numerics and waveforms highly visible from virtually anywhere in the room. LIFEGARD I Monitors Provide a Comprehensive Set of Non-invasive Parameters: ECG – 3-lead acquisition with pacemaker detection Heart Rate – Detected via ECG, SpO2, or NIBP Pulse Oximetry – Nellcor® technology with selectable response modes Non-invasive Blood Pressure – spot check, interval, and stat modes supported by an indicator for elapsed time since last measurement Temperature – Electronic Predictive Thermometry, Welch Allyn SureTemp™ Geared for use as a transport monitor, these compact monitors weigh less than 5 lbs ( 2.1 kg ), have unique carrying handles, and a four-hour battery capacity that keeps the monitor fully operational during longer transport situations. For more typical usage, optional roll stands are also available. Operation is simplistic and intuitive. LIFEGARD I monitors require minimal self training and are versatile enough to be used as either a spot-check monitor ( stat monitor ) or continuous vital signs monitor - color-coded alarms immediately alert the user to any critical events, and “Auto-Set” Alarm Limits adapt quickly to the patient’s current vital sign situation. Documentation is quickly accessible. An optional strip chart printer provides high-resolution waveform documentation with time, date and all numeric values. Every Analogic LIFEGARD I monitor is backed by a full two-year warranty on all parts and service. A customer service hotline allows immediate contact with the factory should a problem arise. >>>
View the product on analogic.com ANALOGIC
C200 DYNAMIC MODE COLUMN.

C200 DYNAMIC MODE COLUMN.

This column gauge is an electronic gauge for connecting 1...8 inductive and incremental probes, pneumatic gauge heads, sensors with analogue current or voltage outputs and gauges with digital interfaces. The high flexibility of connecting sensors and gauges is achieved due to the modular design and the usage of IMBus - modules.- Modular construction - Simple handling - Universal measuring inputs - Comfortable display unit- Highly sophisticated- measuring programs - Easy cascading- Static and dynamic measuring programs ( MIN, MAX, TIR, MEAN and Bore with automatic function ) >>>
View the product on alphagauging.com Alpha Gauging Ltd




  Search    
 
 
 
Search
See all of the sector's products : Electricity/Electronics