Contrôleurs de sécurité électrique (translation in progress): suppliers, wholesalers and manufacturers on Hellopro
Search   


Contrôleurs de sécurité électrique (translation in progress) :

96 products
Select the category
    Selection of 40 products among 96
    AIR SUPPLY & EXHAUST

    AIR SUPPLY & EXHAUST

    Excellent pressure drop and sound characteristics. Suitable for commercial and domestic applications. Supplied complete with long body mounting rings. Easy to remove for cleaning. All models fully adjustable. Description Keeping noise and cost levels down to a minimum are probably the two biggest problems an engineer designing a ventilation system has to face today. The patented Model KSO Exhaust Valve has been developed with these criteria in mind and has a very low noise level even when the pressure drop across it is large. This characteristic allows relatively high air velocities to be used, permitting the selection of the most economical size of ductwork and exhaust valves. Adjustment of the airflow is simple, the inner cone being rotated to the required setting and locked in position with a single nut. Each air valve is supplied complete with a mounting ring from which it can be simply removed for cleaning without affecting the setting of the valve. >>>
    View the product on lindab.co.uk Lindab Limited (Building Products Division)
    CABLE FAULT LOCATOR - BICOTEST T617

    CABLE FAULT LOCATOR - BICOTEST T617

    The Bicotest T617 is designed to offer the telecom technician a high end, long distance TDR at a very competitive price. With all the advanced fault finding features of the T625 optimised for telecommunications cable the Bicotest T617 offers an unparalleled level of functionality and sheer raw performance for the field engineer. It is housed in a rugged and robust field proof enclosure. Features: Easy to operate for long and short range fault finding Optimised for telecoms use 8 preset telecoms tests Large high resolution display Clear waveform trace for accurate diagnosis All faults clearly identified from open circuits to wet joints Single memory feature Supplied complete with: Weatherproof carry case 8 x LR14 'C' battery cells >>>
    View the product on jmwlimited.co.uk JMW Limited
    POWER PROTECTION - DC - MA15 SERIES

    POWER PROTECTION - DC - MA15 SERIES

    Protects panel loads up to 15 Amps in series, unlimited Amps in parallel Suitable for AC or DC application Thermal and short circuit protection Optional LED status indication feature Exceeds requirements of IEC 61000-4-5 10 year product warranty The MA15 Series of surge protection devices protects electronic equipment and computer networks against the effects of 'noise pollution' induced in mains power supplies. MA15 units 'clean up' the effects of industrial noise and surges caused by lightning, switching devices, thyristor controls, transmission system overloads and power-factor correction circuits. Industrial control systems utilising programmable logic controllers (plc) and industrial computers are particularly vulnerable due to the aggressive electrical environments for which they are intended, such as process plants, factories and water treatment sites. Although industrial computers and plcs are designed to be rugged, the extra protection provided by the DIN rail mounting MA15 units is critical. Ideally suited for protecting panel mounted equipment and typically used in the controls section of a motor control centre (MCC), the MA15 range providessurge and RFI protected power. Suitable for AC or DC application, MA15 units reduce both electromagneticemissions and the susceptibility of the associated equipment to emissions from other sources. >>>
    View the product on telematic.com Telematic Ltd
    COMBINATION WAVE TESTERS

    COMBINATION WAVE TESTERS

    The MIG1206 is a hybrid generator with a voltage wave shape 1,2/50 µs at "no load" and a current wave form 8/20 µs at short circuit. One representative application is testing of in circuit installed protection elements e.g. IEC 61643-1. The generator complies with IEC 61000-4-5 basic standard. The peak output voltage and current of the MIG are indicated on the display. The two BNC monitor outputs allow monitoring the voltage and current wave shapes by an oscilloscope. >>>
    View the product on hvtechnologies.com HV Technologies Groupe - HV Diagnostics
    POWER CONTROLLER TSI205

    POWER CONTROLLER TSI205

    The Tundra Tsi205™ Power Controller provides comprehensive monitoring and control of primary-side power parameters and safe transmission of data to a companion secondary-side power subsystem controller IC. Providing theseprimary-side parameters to a secondary-side management device can provide significant system uptime advantages. Hidden fuse faults can be flagged before system downtime occurs. Card-level parameters such as primary-side current and voltage levels can indicate fault trends and drive preventive maintenance activities. Tsi205 also provides control of the intermediate bus isolated power supply during card insertion and extraction. The Tsi205 provides all these primary-side monitoring capabilities. A PI-Link™ interface enables safe transmission of primary side data across the isolation barrier using a low-cost transformer. This link provides data to the Tundra Tsi257™ Power Controller where it can be used and stored. Further, if an un-recoverable error on the secondary side occurs, the Tsi257 can send a signal to the Tsi205 to shutdown primary power. The Tsi205-SIPAV shuts down if primary input sees an over voltage and will automatically retry after a fault, whereas the Tsi205-SIPV provides a warning for over voltage and shuts down after a fault. This part was formerly marketed by Potentia Semiconductor Corporation as the PS-1005 and PS-1005A. >>>
    View the product on tundra.com Tundra Semiconductor
    ASTAT™ SOLID STATE REDUCED VOLTAGE

    ASTAT™ SOLID STATE REDUCED VOLTAGE

    GE offers 3 lines of ASTAT solid state reduced voltage starters. The ASTAT SD is a line of compact, high performance three phase starters, available to 25hp @ 460v. The SD is a full functional soft starter with complete starting/stopping control and fault diagnostics. The ASTAT IBP Plus is a line of bypass solid state starters featuring a fully rated bypass contactor. These starters are rated up to 300HP @ 460v. The design is completely wired allowing quick, simple installation into either new or exisxting installations as a replacement for traditional starters. Bypass contactors are a must for enclosed installations where free air movement is not possible. The ASTAT CD Plus is the most full featured starter in the ASTAT lineup. Parameters include soft start voltage ramp, kick-start, current limiting, an energy saving feature, thermistor input, soft stop, pump control, DC injection breaking, communications, jog/slow speed and tachometer feedback. >>>
    View the product on geindustrial.com/cwc/products?famid=35&lang=en_US GE Motor starters Groupe - GE+Energy
    INVERTER - ADV200

    INVERTER - ADV200

    Field-oriented vector inverter, from 0.75 up to 45kW * AC Mains supply 3ph: 400V –15%…480V +10% 50/60Hz ±5% * Motor ratings from 0.75kW (1Hp) to 45kW (60Hp) * Certifications: CE. UL, cUL and CSA (pending) Features: • Regulation control modes: FOC with Speed feedback, FOC open loop, V/F • Max Output frequency 600Hz • DC Choke integrated • EMC Filter integrated • Dynamic Braking Module integrated up to 75kW • Overload according with IEC146 Class 1 and Class 2 • Heavy duty and Light duty overload management • Up to 4 options on board • Safety Stop card in accordance with EN 954-1 (Cat.3) >>>
    View the product on gefran.com Gefran CRL Ltd
    CAPACITOR OPEN RACK SHUNT BANK

    CAPACITOR OPEN RACK SHUNT BANK

    Shunt Capacitors are primarily used to improve the power factor in the network. They will also improve the voltage stability and reduce network losses. Improving the power factor also means a higher power transmission capability and increased control of the power flow. The installation of capacitors in a transmission or distribution network is called power factor correction or reactive power compensation. Benefits Reduced network losses Increased voltage stability Improved power quality Limitation or reduction of charges for excess reactive power consumption. Increased load possibility on existing transmission lines and transformers >>>
    View the product on abb.co.uk ABB Automation UK
    GENERATOR CONTROLLER – GC-1

    GENERATOR CONTROLLER – GC-1

    A very compact engine and gen-set controller offering all necessary generator protections such as voltage, current, power and frequency. The compact gen-set controller offers optional J1939 communication and remote monitoring. The optional GSM modem will allow the GC-1 to forward SMS/text messages. Features include: * Automatic engine start/stop * Engine protection * Breaker control * Generator protection * Automatic Mains Failure CAN bus J1939 engine communication (option) The GC-1 contains a three-phase AC voltage measuring circuit and is equipped with a graphical display presenting all values and alarms. The unit offers CANbus engine communication and has 6 configurable binary inputs.In addition, the GC-1 can be supplied with a number of different options. Thus, the same hardware is suitable for a variety of different applications. That means costs saved on training and maintenance >>>
    View the product on deif.co.uk DEIF (UK) Ltd
    ENVIRONMENTAL CONTROL MS1000

    ENVIRONMENTAL CONTROL MS1000

    The ms1000 system is designed to generate either latched voltages or currents corresponding to measured values in remote locations. This function is intended to allow radio sensors to directly replace wired-in sensors in applications such as building environmental control where the 3rd party BMS can directly accept analogue signals. Alternatively, it can supply relay outputs for alarm or control functions. A combination of all output types can be created within a single ms1000 system (see below). >>>
    View the product on hanwell.com Hanwell Ltd
    MCE REACTIVE POWER CONTROLLER

    MCE REACTIVE POWER CONTROLLER

    PFC controller MCE (6 and 12 steps) for automatic capacitor bank is designed to measure reactive power in the installation and give the proper orders and instructions for switching on/off the capacitors steps to maintain the preset power factor (cos). All controllers include a microprocessor which ensures an uniform use of the capacitors and contactors through a circular connexion sequence FIFO which considerate the connexion time of each capacitor step. >>>
    View the product on lifasa.com LIFASA
    DIGITAL PUMP LOAD CONTROL

    DIGITAL PUMP LOAD CONTROL

    Power sensor monitors true motor power Three phase and single phase models Waterproof & rugged, large red LED display Compact enclosure with flexible fittings Easy front panel keypad set up Low and high set point trips with relay outputs Adjustable trip timers to prevent nuisance trips Adjustable digital on-delay timer 4-20mA output for computer, logger or recorder Protect pumps and motors Detect dry running, loss of prime or cavitation Detect overloads or under loads Detect bad bearings or jammed impellers Extremely sensitive even at low loads >>>
    View the product on vydas.co.uk Vydas International Marketing
    AIR CURTAIN SMARTELEC

    AIR CURTAIN SMARTELEC

    Simple installation – wiring connections are direct to the controller, no intermediary terminal blocks are required Easy programming – users merely select whether they require the heat on or off, the required fan setting (2 or 3 speed), and the outlet temperature setting Surface mounted or recessed switchbox. Recessed units fit into an alternative MK back box (not supplied) For new installation factory fitted power units are mounted in the air curtain and pre-wired to air curtain components Retrospective fitting – can be fitted into some existing air curtains or placed in an enclosure elsewhere and wired to the existing air curtain BMS and internet protocol compatible Maintains constant outlet temperature at required room setting with tolerance for countering air curtain velocity Air outlet sensor mounted within the air curtain to enable accurate temperature settings Suitable for use with Airbloc AC and Airbloc ACR 3 phase electrically heated units >>>
    View the product on airbloc.co.uk/htm/airbloc/php/index.php Airbloc
    AMKAMAC CONTROLLERS SERIES AS-PLXX

    AMKAMAC CONTROLLERS SERIES AS-PLXX

    AMKAMAC controllers are a PLC series with the latest generation of motion control functions. Fast processing of the PLC code with generous program and data memory ensures an efficient utilization of your resources. You select your individually configured multi-axle controller from two different power classes and a variety of expansion options and receive a high-end solution with all degrees of freedom. >>>
    View the product on amk-antriebe.de AMK
    TRANSFER PANEL LC

    TRANSFER PANEL LC

    Transfer panel LC open or delayed transition Description The LC automatic transfer panel combines reliability and flexibility in a small, economical package for transferring loads between the utility and generator set. The control monitors utility power. When utility power fails or is unsatisfactory, the control starts the generator set and transfers the load to the generator set. The switch automatically transfers loads back to the utility when acceptable utility power returns. Features Positive interlocking - Mechanical and electrical contactor interlocking prevents source-to-source connection through the power or control wiring. Electronic control - Reliable, digital electronic control system with system surge voltage isolation, under voltage monitoring on each power source, four standard normal/emergency source time delays, and diagnostic LEDs. • High isolation transformers for AC power inputs • LED lamps verify control status • Choice of 2 control packages Options Delayed (programmed) transition - Available on panels rated from 250 to 500 Amps, this option helps prevent fuse blowing and circuit breaker tripping when transferring inductive loads such as large motors and transformers. Extends transfer time of the transfer panel mechanism to allow load induced voltages to decay prior to connection to the oncoming source. Battery chargers - 2, 12 or 15 Amp battery chargers are available as factory installed options to reduce field wiring expense. Three-wire start module - This option modifies the standard LC two-wire start circuit to a three-wire start system required by some generator sets. Manual override switch - This key selector switch provides a manual transfer capability. The manual override switch uses the power from the source to which the switch will transfer, in order to bypass the control and transfer load. >>>
    View the product on cumminspower.com/cpghome/home.jhtml CUMMINS POWER GENERATION
    CONTROL PANELS AND SOFTWARE - WOP-IT®

    CONTROL PANELS AND SOFTWARE - WOP-IT®

    WOP-iT® – An Overview A new class of control panels and software Until now the worlds of monitoring & control and of SCADA were strictly separated: On one side classical control panels with all necessary interfaces with the sensor / actuator level. On the other side PCs / IPCs with expensive SCADA visualization software. WOP-iT® now bridges this gap: Innovative monitoring & control and affordable SCADA alternatives - in one system! This new device class – Management Execution Interfaces (MEI) – has become possible by incorporating Internet standards throughout the design process. This safeguards your investments and allows you lean >>> Solutions: No more special hardware and software is needed to access the terminal and the connected peripherals. All you need is a LAN connection or a standard modem. Device Features • Ethernet on board • S7 gateway • Multi-driver (multiple simultaneous communication channels) • Active (!) messaging (WOP-iT® can, for instance send its own mails) • Wide range of visualization functions (SCADA-like) • Integrated browser allows access to all data in the customer Intranet • Complete remote access to all WOP terminals possible without special hardware • Data interface to MS-Office • Wide range of mathematical functions • Each PC/each WOP-iT® can be used as a full-fledged client • MPI, Profibus and CANbus interfaces • Upon request also with integrated PLC >>>
    View the product on lauer-systeme.net Elektronik Systeme Lauer
    STOP SWITCH, DC & AC ISOLATORS

    STOP SWITCH, DC & AC ISOLATORS

    Stop Switch, DC & AC Isolators For use with all turbine models, these switches allow the user to isolate the DC supply to a load, to apply an electrical brake to the turbine and to isolate the AC side of an inverter (if connected). The AC isolator is a 4-pole 20A lockable switch, which should be used when connecting Grid-Tied Inverters to a mains supply. The switch should be mounted close to the main consumer unit, between a spare 16A breaker and the inverters. The DC Isolator and Brake should be connected to the output of the wind turbine, between it and the load (inverter, batteries etc). The main rotary switch is rated at 63A and is 4-pole. In this mode, the internal connections have been pre-wired in pairs of 2 poles, giving a massive switching capacity of 120A. Also mounted inside these switches are a low resistance dump load, allowing the turbine to slowed to a safe level before applying a direct short circuit to the turbine output wires. >>>
    View the product on futurenergy.co.uk Futurenergy Ltd
    CONTROL STATION - ZONE 1 CONTROL STATIONS EEXE

    CONTROL STATION - ZONE 1 CONTROL STATIONS EEXE

    Zone 1 Control Stations Eexe (Increased Safety) When choosing control stations, it is important to take account of the resistance of enclosures with regards to its location, climate, and resistance to chemical products, mechanical stress or temperature variations. Therefore constitutes three main criteria for choosing control stations. Specification High impact resistance polycarbonate body and cover Polyamide compact box and cover 2 x M20 clearance entries at the bottom 1 earth terminal block 2 x 2.5mm2 Certification Eexed IICT6 98661 Brass Earth Plate required for SWA cable Zone 1 & 2 - 21 + 22 Suitable for dusty environments Control stations can be custom made if required. Please contact the sales department with your requirements >>>
    View the product on hazardousareadivision.co.uk Hazardous Area Equipment
    212V2 - BENCHTOP IONISER

    212V2 - BENCHTOP IONISER

    The Model 212v2 Benchtop Ioniser is a compact unit which complements the Meech Series 200 product range. The Model 212v2 provides excellent work station coverage and a high level of ESD protection. It has been specifically designed to meet the demanding performance requirements in applications such as: ·Semiconductor manufacture · Electronics assembly & testing · Test and re-work · Optics, contact lenses & fibre optics · Medical device manufacture & packaging · Wave soldering Features Benefits Balance ionisation (typical) +/- 10V Prevents possible ESD damage in sensitive electronic applications, reduces scrap and saves on replacement costs. Dirty pin indicator and audible alarm Particularly important in applications where balanced ionisation is key to prevention of ESD damage to components. Also, informs the operator when maintenance is required (emitter pin cleaning). Removable pins Easy to clean and replace. Minimum maintenance downtime. Two fan speed settings Can be set for optimum operator comfort and ionisation range. Small footprint Takes up little room, allowing more space for operators’ work activity. Technical Characteristics Dimensions 160mm x 160mm x 95mm (H x W x D) Weight 0.65 Kg Air Volume Output 15 – 20 lts/sec (33 - 43 cfm) Noise Level 46 dBA at 1 metre distance Decay Time (typical) < 4 secs @ 305mm distance and max fan speed. (1000 to 100v) Input Voltage 24V DC (switchmode PSU) Power consumption 12W Ozone < 0.01 ppm Calibration Factory calibrated at 305 mm >>>
    View the product on meech.com Meech International
    GALVANIC ISOLATORS - SERIAL DATA CONVERTERS

    GALVANIC ISOLATORS - SERIAL DATA CONVERTERS

    Galvanic Isolators - Serial Data converters 2 wire isolator 6580 is exceptionally narrow and small size, it is only 9,5 mm wide and therefore excellent solution for signal isolation in PLC or application where installation space is critical. The latest model 6740 is processor based isolator/transmitter for all general signals like mA, V, mV and temperature sensors. For high speed response application the model 641 is recomended. High accuracy output can reached with up to 500 Hz (maximum up to 5 kHz). New data converter DCS770 for USB-RS485 is a low cost and small size converter taking its energy from USB port. >>>
    View the product on nokeval.com Nokeval
    EFOY POWER MANAGER

    EFOY POWER MANAGER

    Reduces Soldier's load! Harvest and manage energy from several different sources Possible power sources include: batteries of various chemistries and states of charge, fuel cells, photovoltaic cells, typical battery chargers, and automotive battery buses Manage energy storage and power distribution within your network as a power distribution hub Create the different voltages and current limitations needed by your equipment Provide critical user feedback information Efficient operation, easy to carry - small and lightweight >>>
    View the product on smartfuelcell.de SFC Smart Fuel Cell
    CONTROL EQUIPMENT - DGC 2000

    CONTROL EQUIPMENT - DGC 2000

    Diesel Generator Controller, Automatic Mains FailureThe DGC 2000 is a third generation microprocessor based controller designed for most types of diesel generators systems in fully automatic mode and via remote or manual start/stop commands. The DGC 2000 scans sixteen discrete sensors and true RMS measurements of the mains and generator three-phase voltages and load currents. Incorporating analogue inputs from engine temperature, oil pressure, coolant and fuel levels into its advanced protective algorithm while continuously performing self-status tests and measuring its own battery supply voltage. >>>
    View the product on softstartuk.com Softstart (UK) Ltd
    PHOENIX MULTI CONTROL

    PHOENIX MULTI CONTROL

    Phoenix Multi Control This is a remote control and monitoring panel for the Phoenix Multi/MultiPlus. In addition, the remote panel also offers PowerControl and PowerAssist, (simply by setting a maximum AC current with a 0 to 16A rotary knob), thus preventing the shore supply or a genset from being overloaded. The brightness of the LED?s is automatically reduced during night time. Connection to the Multi is with a standard UTP ? cable. >>>
    View the product on victronenergy.com Victron Energy B.V.
    CABLE FAULT LOCATOR - BICOTEST T625

    CABLE FAULT LOCATOR - BICOTEST T625

    The Bicotest T625 high specification handheld TDR cable fault locator is Bicotest's most advanced TDR cable tester. With a range of 0 to 20 kilometres, it out performs many other TDRs. The Bicotest T625 is designed to offer the field technician a high end, long distance TDR in a rugged and robust package. Coupled with PC connectivity and a software package for displaying and storing waveforms for offline analysis and comparison, the Bicotest T625 offers a complete solution for the field engineer. It is ideally suited for telecom and LV applications. Features: Easy to operate for long and short range fault finding Use on any type of metallic cable Fault find on live AC with the optional fused blocking filters Large high resolution display Clear waveform trace for accurate diagnosis All faults clearly identified from open circuits to wet joints Zoom mode for detailed waveform examination 12 memories for on site waveform storage and comparison >>>
    View the product on jmwlimited.co.uk JMW Limited
    POWER PROTECTION - SINGLE PHASE - MA100 SERIES

    POWER PROTECTION - SINGLE PHASE - MA100 SERIES

    Single Phase and Three Phase versions available Suitable for wall or surface mounting Dual redundant, individually monitored MOV networks Added Thermal Fuse protection 10 Year 'No Fuss' Warranty The MA100 Series ac power system surge protectors prevent surges and transient overvoltages from damaging electronic systems such as instrumentation control panels, telemetry outstations and fire and security alarm installations. These 20kA protection devices are available in single phase (MA101) and three phase (MA103) versions and are supplied in a range of voltage options. An optional, IP65 rated weatherproof enclosure is available for this range should it be necessary. >>>
    View the product on telematic.com Telematic Ltd




      Search    
     
     
     
    Search
    See all of the sector's products : Electricity/Electronics