Cartes de bus d'extension (translation in progress) - Hellopro
Search   


  • Electricity/Electronics > Conversion d'énergie (translation in progress) > Transmission de signaux électriques (translation in progress) > Transmitters
  • Industrial IT > Equipment > Industrial network > Various industrial IT equipment
  • Industrial IT > Equipment > Industrial network > Transmitters
  • Networks - Computing > Hardware > Computer expansion cards > Interface cards
  • Networks - Computing > Hardware > Computer expansion cards > PCI cards
  • Networks - Computing > Hardware > Computer expansion cards > Bus cards

See all sector categories "Industrial IT"

View associated products


Cartes de bus d'extension (translation in progress) :

6 products Flux RSS
CARDS - SYSTEM 470

CARDS - SYSTEM 470

SYSTEM 470 Back to System 470 ADC Resolution: 16-bits, including sign. Gain Accuracy: ± 0.05%. Gain Stability: ± (0.01% + 0.003%/°C). Linearity: ± (0.02% + ½LSB). Static Crosstalk: 120dB between channels, dc to 1KHz with 350 ohm source; 10 V maximum non-overloaded input. Zero Offset: ± 10 m V, channel-to-channel. Zero Stability: ± (5 m V RTI + 1.25 mV RTO)± (0.5 m V/ oC RTI + 0.1mV/oC RTO). Noise: 8.5mV RTI, 1.5mV RTO at 10 KHz Throughput 3.7mV RTI, 1.5mV RTO at 1 KHz Throughput Noise = [(RTI x Gain)² + RTO²]1/2 >>>
View the product on neff.com Neff Instrument Corporation
CARDS - SYSTEM 471

CARDS - SYSTEM 471

SYSTEM 471 Back to System 471 ADC Resolution: 16-bits, including sign. Gain Accuracy: ± 0.05%. Gain Stability: ± (0.01% + 0.003%/°C). Linearity: ± (0.02% + ½LSB). Static Crosstalk: 120dB between channels, dc to 1KHz with 350 ohm source; 10 V maximum non-overloaded input. Zero Offset: ± 10 m V, channel-to-channel. Zero Stability: ± (5 m V RTI + 1.25 mV RTO)± (0.5 m V/ oC RTI + 0.1mV/oC RTO). Noise: 8.5mV RTI, 1.5mV RTO at 10 KHz Throughput 3.7mV RTI, 1.5mV RTO at 1 KHz Throughput Noise = [(RTI x Gain)² + RTO²]1/2 >>>
View the product on neff.com Neff Instrument Corporation
CARDS - SYSTEM 495

CARDS - SYSTEM 495

System 495 Back to 495 Specifications: Full Scale Input: 12 programmable steps provide bipolar input ranges from 5mV to 10.24 V Full-Scale Accuracy: ± 0.1% of FS at zero frequency Full-Scale Stability: ± 0.02% of FS at constant temperature; ± 0.005%/° C Input Impedance: 10 Megohms shunted by 500 pF. Source Current: Less than 1.0 nA at 25 oC, ± 0.1 nA/oC. Zero Stability: ±5 uV RTI ± 1.0 mV RTO at constant temperature; ±1.0 uV/oC RTI, ±100 uV/oC RTO. Noise: BW Noise, 3 Sigma 100.00 KHz 57 uV RTI + 2 mV RTO 10.00 KHz 18 uV RTI + 2 mV RTO 1.00 KHz 6 uV RTI + 1 mV RTO Common Mode Voltage: ± 10 Vdc peak AC operating, ± 30 V without damage. Common Mode Rejection: 66dB + gain in dB to 120dB max, dc to 60 Hz with 350-ohm source imbalance. Filter: 6-pole Bessel filter with four programmable cutoff frequencies. Each frequency is determined by a plug-in resistor network over the range of 100 Hz to 200 KHz. Default frequencies are 10 KHz, 20 KHz, 50 KHz and 100 KHz. Phase Coherency: Phase shift matched channel-to-channel within 5 degrees with amplifiers on same gain and filter step, dc to cutoff. Voltage Substitution Calibration: Solid state relay provided to switch amplifier input terminals to common CAL bus under program control. Excitation Supply Feedback: Solid state relay provided to switch amplifier input terminals to excitation supply sense lines under program control. Shunt R Calibration: Solid state switch to apply shunt resistor across bridge arm under program control. Switch ON resistance less than 30 ohms. Auto-Balance: Auto-balance DAC outputs a voltage between 0 and the excitation supply voltage level. Bridge Conditioner Mode Board: Plug on circuit board provided to mount bridge completion, shunt R cal and balance limit resistors. 1, 2 and 4 arm circuits may be used with either local or remote supply sensing. Excitation Supply: Output Voltage: Programmable over the range of 0 to 10 volts with a 12-bit DAC. Output Current: 100 mA maximum operating current; short-circuit protected. Output Noise: Less than 100 uV pk-pk in 1 KHz bandwidth. Line Regulation: Less than 0.1% change for 10% line variation. Load Regulation: Less than 0.1% change from no load to full load. Remote Sensing: Positive and ground sense leads are provided for remote sensing. 8-Input Trigger Module Back to 495 The 495030 Trigger module provides eight trigger input signals for the system. Optic coupling is used to isolate all inputs from each other and from system ground. Each input may be configured for either TTL or high voltage AC/DC operation by means of plug-on jumper links. Schmitt trigger gates are employed to further enhance noise immunity. >>>
View the product on neff.com Neff Instrument Corporation
CARDS - SYSTEM 620/600

CARDS - SYSTEM 620/600

Series 600 (620650, 620654) Back to 600 Specifications: Speed: Program selected:100 KHz or 50 KHz. Ranges: Program selected; 12 binary steps: 100 KHz: ±5 mV FS to ±10.24V 50 KHz: ±0.625 mV FS to ± 10.24V. Filter: F 0 = 1 Hz, 10 Hz, 100 Hz and 1KHz. 620650: 2-Pole Butterworth 620654: 6-Pole Butterworth Resolution: 16-bits (15 + sign bit). Basic Accuracy: ± (0.02% FS + 2 uV) for 30 days at constant temperature after automatic calibration; includes effects of gain error, offset, non-linearity, and non-overloading crosstalk. Gain Stability ± 0.002% FS/oC change from automatic calibration temperature. Zero Stability ± 1.0 µV/oC change from automatic calibration temperature. Input Configuration: Guarded differential input on each channel; floating or grounded signal sources measured without degradation. Common Mode Voltage, Operating: ± 10 Vdc or peak ac. Common Mode Rejection Ratio: 120 dB max (66 dB + gain in dB + filter attenuation), dc to 60 Hz with 350 ohm source imbalance. Source Current: ± (1 nA @ 23oC + 0.1 nA/oC). Input Overload Without Damage: ± 100 Vdc or peak ac, common mode or normal mode. Sample & Hold (620654 preamp only): Acquisition Time: 30 uS. Droop (Hold Mode ): 0.5 mV/mS. Aperture Uncertainty: 100 nS, max. Noise: Total Noise RTI = [(N1)2 + (N2)2]1/2 /A where N1 = RTI noise; N2 = RTO noise; A = system gain = 10.24 V/FS Range. Noise specifications are 3 Sigma limit, peak-to-peak. f0 N1 N2 1Hz 1uV 2500uV 10Hz 1uV 2500uV 100Hz 2uV 2500uV 1KHz 6uV 2500uV Offset: Included in basic accuracy specification. Static Crosstalk: Included in basic accuracy specification. Crosstalk (Adjacent Channel Overload): ±0.02% FS (only affects channel following overloaded channel in scan list). Non-Linearity: Included in basic accuracy specification. Automatic Calibration: On command, uP adjusts zero and gain of each channel to within basic accuracy specification and verifies calibration. Analog Output: Unfiltered (wideband) output at ±5 mA from each preamp; available at rear panel. Control/Display Panel: 32-character alphanumeric display and keypad for entering instructions. Autorange (50 KHz only): Post amplifier provides autorange over a 1-to-32 gain range in six steps. Combined with preamp gain, the following ranges are available: Preamp Gain Autoranges 512 ±0.625 mV to ±20 mV 64 ±5 mV to ±160 mV 8 ±40 mV to ±1.28 V 1 ±320 mV to ±10.24 V >>>
View the product on neff.com Neff Instrument Corporation
CARDS - SYSTEM 730

CARDS - SYSTEM 730

System 730 (730060) Back to 730 Specifications: Full Scale Inputs: Twelve programmable steps provide bipolar input ranges of ± 5mV to ± 10.24V Full Scale Accuracy, dc: ± (0.02% FS + 2 uV) for 30 days at constant temperature Zero Stability: ± 1m V/° C change from calibration temperature. Passband Ripple: < 0.005dB Channel-to-Channel Phase Match: 1° for passband frequencies to 3KHz (8KHz sample rate). AC Coupling: -3dB at 1.0Hz Input Impedance: dc Coupled: 10 M Ohms in parallel with 500pF ac Coupled: 1 M Ohms in parallel with 500pF. Common-Mode Rejection: 66dB + gain in dB to 120dB max., dc to 60Hz with 350 Ohm source imbalance, in dc coupled mode. Voltage Substitution Calibration: Solid state relay provided to switch amplifier input terminals to common CAL bus under program control. Stopband Rejection: -120dB Unfiltered, ± 10.24V @ 5mA from each channel. Excitation Supply: Programmable to 10V with 12 bit resolution, 50 mA per channel. Excitation supply readback supported. Autobalance: 12 bit resolution. Invoked by computer. Physical Dimensions: 7-inch panel height in 19" rack; 23-inch depth behind front panel. NEFF recommends that assemblies be mounted in a 19-inch rack with 30-inch depth to accommodate connector build-up. Power Requirements: 105V to 130V (220V to 250V), 50 to 400 Hz, 700W. Cooling Requirements: To be mounted in cabinet with unobstructed airflow and equipped with a 300cfm blower. Environmental: 0° C to 50° C, 90% relative humidity. Will withstand shock and vibration of normal shipping and handling of laboratory equipment. >>>
View the product on neff.com Neff Instrument Corporation


  Search    
 
 
 
Search
See all of the sector's products : Industrial IT