Alimentations sans interruption (translation in progress) - Hellopro
Search   


See all sector categories "Electricity/Electronics"

View associated products


Alimentations sans interruption (translation in progress) :

35 products Flux RSS
FIRST DATA CENTER - COMET UPS

FIRST DATA CENTER - COMET UPS

Comet UPS (40-150 kVA) Mission Critical UPS The most trusted solution for high reliability applications Whether you are protecting a large server farm or air traffic control tower, the COMET UPS has proven to be the most reliable solution for mid-range power protection applications. The COMET uses a true on-line topology regenerating 100% of the output power to guarantee complete isolation and protection from all utility power problems. Combined with features like 95% efficiency, less than 3.5% output distortion and MGE's unique Digital Power Quality IGBT inverter technology the COMET also boasts some of the most favorable specifications of any UPS. Trusted by IT professionals as the industry standard solution, COMET has now become one of the best selling UPSs in its class. Comet is available as a UL 924 system for Emergency Lighting Applications. Find out more about MGE UL 924 Certified products Features True on-line topology Very high efficiency MGE Transformerless technology Dual input power sources for optimum reliability Digital Power Quality IGBT inverter technology Advanced battery management for maximum battery life Generator friendly Compact footprint Network based software for multi-server control SNMP manageable Graphical User Interface with color touch screen Scalable power levels Case study MGE Takes Sci-Quest Science Center into New Power Dimension... Download the case study (pdf, 120 KB) MGE UPS SYSTEMS - The Choice of IT Industry Leaders 3 COM ABN AMBRO AIRTOUCH ANDERSEN CONSULTING AOL BANK OF AMERICA BEAR STEARNS BROADCOM CATERPILLAR CISCO CLARIFY DELOITTE & TOUCHE DOW JONES FUJITSU MICROELECTRONICS F.A.A. GLOBAL ONE HARLEY DAVIDSON IBM MICROSOFT MOTOROLA NASA NEWBRIDGE NETWORKS QUALCOMM SECRETARY OF STATE SPRINT SUN MICRO YAHOO and thousands more...... >>>
View the product on mgeups.com MGE UPS SYSTEMS
FIRST DATA CENTER - CRITICAL BUS SYNCHRONIZATION

FIRST DATA CENTER - CRITICAL BUS SYNCHRONIZATION

MGE's Critical Bus Synchronization (CBS) Module synchronizes the outputs of two or more independent UPSs. Synchronized outputs allows the critical load to be transferred to any UPS at any instant, maximizing the availability of all the UPSs. If the UPSs are not synchronized, transferring the critical load between UPS may be inhibited to protect the load from damage and interruption. Combined with the MGE Digital Static Transfer Switch (automatically selects the preferred source from two input sources), loads can be transferred from one UPS source to another with no interruption, enhancing power system reliability. Because multiple power sources are available, UPSs can be serviced without interruption to the critical load for easy maintainability. Applications Distributed redundant configurations using the MGE Digital Static Transfer Switch Features Field proven design Fully automatic operation User definable settings Detailed status display Easy retrofit installation No heavy cable links Transparent operation with the UPS Fully compatible with the MGE Static Transfer Switch Protects loads from damage due to out of sync transfers >>>
View the product on mgeups.com MGE UPS SYSTEMS
FIRST DATA CENTER - GALAXY 3000 UPS

FIRST DATA CENTER - GALAXY 3000 UPS

The first data center grade UPS in the 10-30 kVA power range. If there's one concept MGE understands, it's the importance of staying online. Throughout our 30 years in the UPS industry we have stayed pretty quiet in the background, developing a strong reputation among the electrical engineering community as the rock solid solution for protecting critical infrastructures. Today with $700 million in sales MGE has grown into the world's largest three phase UPS company and the UPS of choice for most of the IT industry leaders own facilities. Applying the same technology we have perfected in our high power data center UPS modules, we developed the Galaxy 3000 to be an ultra high availability solution for lower power ranges. The Galaxy 3000's features rich offering includes a power factor corrected input, internal batteries, maintenance bypass, and four color graphical user interface all standard making it a truly all-in-one compact solution. Galaxy 3000 is available as a UL 924 system for Emergency Lighting Applications. Find out more about MGE UL 924 Certified products Features True on-line topology Power Factor Corrected Input Compact Footprint Network based power management Fault tolerant architecture Scalable power levels User friendly graphical interface Digital Power Quality Management Power surge stabilization for IT equipment start-up Generator friendly technology MGE UPS SYSTEMS - The Choice of IT Industry Leaders 3 COM ABN AMBRO AIRTOUCH ANDERSEN CONSULTING AOL BANK OF AMERICA BEAR STEARNS BROADCOM CATERPILLAR CISCO CLARIFY DELOITTE & TOUCHE DOW JONES FUJITSU MICROELECTRONICS F.A.A. GLOBAL ONE HARLEY DAVIDSON IBM MICROSOFT MOTOROLA NASA NEWBRIDGE NETWORKS QUALCOMM SECRETARY OF STATE SPRINT SUN MICRO YAHOO and thousands more...... >>>
View the product on mgeups.com MGE UPS SYSTEMS
FIRST DATA CENTER - GALAXY 4000 UPS

FIRST DATA CENTER - GALAXY 4000 UPS

Where reliability meets performance The Galaxy 4000 separates itself from other UPS modules with technology that increases performance and reliability, all at a competitive cost. The Galaxy 4000’s IGBT rectifier significantly minimizes input harmonics and the Power Factor Corrected Input reduces installation costs thanks to smaller cabling and generator costs. Unmatched from a performance standpoint, the Galaxy 4000’s unique fault tolerant architecture safely manages output faults without compromising the UPS system. Even common surge currents during output do not result in voltage deviation thanks to the Galaxy 4000’s Digital Power Quality Management technology. Technical Advantages IGBT rectifier virtually eliminates reflected distortion (2% THD from 0% to 100% loads). This avoids polluting the utility power Transistorized IGBT rectifier results in fewer parts and higher reliability Low UPS to generator sizing Power Factor Corrected Input (.99 pf) saves on installation and energy costs Digital Power Quality Management (DPQM) provides precision voltage regulation True on-line double conversion technology fully isolates and protects against all power quality disturbances Power surge stabilization system regulates voltage even under surge conditions common in IT and Industrial environments Fault tolerant architecture protects loads and UPS module during unintended faults Easy and quick to install Front only access User friendly graphical interface SNMP Network Based Power Management* Scalable power levels *Based on maximum input current of UPS module Galaxy 4000 40kVA is available as a UL 924 system for Emergency Lighting Applications. Find out more about MGE UL 924 Certified products MGE UPS SYSTEMS - The Choice of IT Industry Leaders 3 COM ABN AMBRO AIRTOUCH ANDERSEN CONSULTING AOL BANK OF AMERICA BEAR STEARNS BROADCOM CATERPILLAR CISCO CLARIFY DELOITTE & TOUCHE DOW JONES FUJITSU MICROELECTRONICS F.A.A. GLOBAL ONE HARLEY DAVIDSON IBM MICROSOFT MOTOROLA NASA NEWBRIDGE NETWORKS QUALCOMM SECRETARY OF STATE SPRINT SUN MICRO YAHOO and thousands more...... >>>
View the product on mgeups.com MGE UPS SYSTEMS
FIRST DATA CENTER - PMM PLUS / PMM ULTRA

FIRST DATA CENTER - PMM PLUS / PMM ULTRA

Integrated Static Transfer Switch with Distribution System (30 - 300 kVA) Dual input distribution with automatic source selection -the no downtime distribution solution. No downtime! No exceptions! — is the result of the PMM Plus and PMM Ultra critical power distribution system. At the heart of the distribution system is MGE‘s industry leading digital static transfer switch. Fed by two independent AC power sources (a preferred and alternate source), the transfer switch instantly detects power quality deficiencies and rapidly and seamlessly transfers to an alternate input source, without interruption to the critical load. This uninterrupted access to dual independent power sources offers unmatched reliability, availability and serviceability the way no other solution can. Coupled with MGE‘s high K-factor transformer distribution system the PMM Plus and PMM Ultra offer complete isolation, harmonic distortion elimination, power conditioning and distribution for up to 252 breakers in a single system. Ideal for any application where downtime is unacceptable. >>>
View the product on mgeups.com MGE UPS SYSTEMS
UPS CHLORIDE 70-NET

UPS CHLORIDE 70-NET

Secure Power Always Available from 10-60 kVA, 70-NET is a reliable, user friendly UPS that is designed for easy installation, control and use. The product is ideal for the protection of the most critical environments including networks, industrial applications and management systems. The product can be perfectly integrated in computing environments, due to its quiet operation and compatibility with a wide range of communication interfaces. >>>
View the product on chloridepower.com Chloride Power Protection
MINI INVERTER - RINV75

MINI INVERTER - RINV75

Mini Inverter Code: RINV75 MP75 - 12v 75w PowerSource. Transform your vehicle into a mobile office or home from home and never be caught short of electrical power again! Simply insert the MP:75 into your car's cigarette lighter socket and plug in any appliance upto 75w e.g. laptop Barcode: 5011274007508 Packaging: Boxed Euro Slot Pack Dimensions: 183 x 185 x 55 Enlarge Image Specification Summary: Maximum power rating (watts) 75 Peak power (watts) 0.01 seconds 150 Stand by cutrrent (amps) 0.1 Waveform Modified Sine Efficency 90% Input voltage range 10-15 volts DC 240v AC socket (BS approved) 3 pin Fuse (amps) ~ Weight (kgs) 0.245 Certification e and CE approved European part number REINV75 / RSINV75 >>>
View the product on ringautomotive.co.uk Ring Automotive Ltd.
MASTERGUARD SERIES A 0,7 - 3 KVA

MASTERGUARD SERIES A 0,7 - 3 KVA

On-line protection for Data, PCs and networks The MASTERGUARD Series A Uninterruptible Power Supplies from Siemens protect data and hardware in networks and complex computer systems from voltage fluctuations and power failure. Power Failures Voltage amplitude varaitions Frequency variations Voltage distortion Voltage surges Interference voltage Intermittent voltage MASTERGUARD - protects PCs and Networks Personal computer Workstations Networks, server applications (LAN, WAN etc.) Telecommunications systems MASTERGUARD: On-line technology with bypass In normal operation, the MASTERGUARD converts the mains AC voltage into DC voltage which supplies a battery and an inverter with energy. The inverter generates a sinewave AC voltage which is permanently available at the output. If and when power problems strike, the battery delivers the required power to the inverter. The additional Bypass system integrated into the UPS device guarantees an unprecented level of power supply security: In overload or short-circuit conditions the bypass system automatically switches mains power directly through to the load. MASTERGUARD talks to your computer Thanks to this versatility, MASTERGUARD can be used according to individual needs: Operator-free applications Direct communication between UPS and computer Connecting the UPS as a client in the network with central monitoring Transmitting operational status to external signalling systems >>>
View the product on masterguard.de MASTERGUARD Groupe - CHLORIDE POWER PROTECTION
RECTIFIER MODULE - FLATPACK2 24/2000 NICD

RECTIFIER MODULE - FLATPACK2 24/2000 NICD

Versatile and powerful solution for any application The combination of cost-effective design, power density and reliability makes the Flatpack2 a product family that truly stands outs and provides unparalleled network availability. The versatility of the Flatpack2 rectifier means that it can be used in a wide variety of 48VDC and 24VDC applications across the globe. Product Description The Flatpack2 NiCd is a battery charger and rectifier for stand-alone use or for working in parallel as part of a DC power system controlled and monitored by the Smartpack. It’s output voltage window is optimized for use with NiCd batteries. Flatpack2 is optimized for a wide range of system sizes. Digital communication over CAN bus with Smartpack simplifies system design and enhances flexibility. Realization of Flatpack2 systems is possible by fitting 4 rectifiers across a 23” or 19” shelf. Key Features Highest efficiency in minimum space Resonant topology makes the module efficiency industry leading and contributes to the rectifier’s ultra compact dimensions. Digital controllers Primary and secondary controls are digitalized, enabling excellent monitoring and regulation characteristics. Thus, the number of component has been reduced by 40% - for highly reliable, long life, trouble free DC power systems. Heat management Front-to-back air flow with chassis-integrated heat sinks gives the module the most suitable working environment and no limitations in the scalability of the desired system solution. Unique connection A true plug-and-play connection system: time-to-install and cost-reducing solution. Global approvals Flatpack2 NiCd is CE marked. Additional Technical Specifications AC Input Voltage 85-300 VAC (Nominal 185 – 275 VAC) Frequency 44 to 66Hz Maximum Current 12.5 Arms maximum at nominal input and full load Power Factor > 0.99 at 50% load or more Input Protection o Varistors for transient protection o Mains fuse in both lines o Disconnect above 300 VAC DC Output Voltage o Adjustable range: 21.5-36.0 VDC o Default voltage: 26.7 VDC Output Power 2000 W at nominal input Maximum Current 70.0 Amps at 29 VDC and nominal input Current Sharing ±5% of maximum current from 10% to 100% load Static voltage regulation ±0.5% from 10% to 100% load Dynamic voltage regulation ±5.0% for 10-90% or 90-10% load variation, regulation time < 50ms Hold up time > 20ms; output voltage > 21.5 VDC at 1500W load Ripple and Noise < 100 mV peak to peak, 30 MHz bandwidth < 0.96 mV rms psophometric Output Protection o Overvoltage shutdown o Fuse on output o Short circuit proof o High temperature protection Other Specifications Efficiency Typical 91% Isolation 3.0 KVAC – input and output 1.5 KVAC – input earth 0.5 KVDC – output earth Alarms: o Low mains shutdown o High temperature shutdown o Rectifier Failure o Overvoltage shutdown on output o Fan failure, one or two fans. o Low voltage alarm at 21.0V o CAN bus failure Warnings: o Low temperature shutdown o Rectifier in power derate mode o Remote battery current limit activated o Input voltage out of range, flashing at overvoltage o Loss of CAN communication with control unit, stand alone mode Visual indications o Green LED: ON, no faults o Red LED: rectifier failure o Yellow LED : rectifier warning Operating temp -40 to +75°C (-40 to +167°F) Storage temp -40 to +85°C (-40 to +185°F) Cooling 2 fans (front to back airflow) Fan Speed Temperature and load regulated MTBF > 200, 000 hours Telcordia SR-332 Issue I, method III (a) (Tambient : 25°C) Acoustic Noise < 65dBA at nominal input and 70% load (Tambient < 30°C) Humidity o Operating: 5% to 95% RH noncondensing o Storage: 0% to 99% RH non-condensing Dimensions 109 x 41.5 x 327mm (wxhxd) (4.25 x 1.69 x 13”) Weight 1.9 kg (3.97 lbs) >>>
View the product on eltekvalere.com Eltek Valere
ATLAS 100KVA

ATLAS 100KVA

Description: Powertronix has proved its high technological and design qualities with the design of ATLAS. True double-conversion on-line technology, high frequency conversion, digital control,power factor > 0.95, low noise level, selectable “Power Save Mode”, high efficiency, emergency circuit (EPO) for immediate shutdown, all these are characteristics allowing us to confirm that ATLAS UPS systems are an expert solution for any type of power supply requirement you may have. Product data: Code: AT1000 Input frequency: 50-60 Hz Output frequency: 50-60 Hz Number of input phases: 3 Number of output phases: 3 Output Power: 100.00 KVA Input voltage: 380 ÷ 415 V Output voltage: 380 ÷ 415 V External batt backup time: 10 ÷ On request min. Parallelable up to: 8 >>>
View the product on powertronix.it Powertronix Spa
STANDBY POWER SUPPLY - P673

STANDBY POWER SUPPLY - P673

The P673 Standby Power Supply is a set of four components which make up a simple and versatile battery backed power supply. The system is designed for use with RTK Engineering's Alarm Annunciators and consists of a stabilised variable power supply, a P607 Trip Amplifier, a blocking diode and two 12V DC batteries.The separate component solution gives total flexibility for both power supply size and battery capacity. This makes it possible to select any PSU size with any battery size, avoiding the problem of having to compromise on a component which may not exactly meet the system requirements. The P673 System is an extremely cost effective solution, ideal for panel builders and system designers as these components can easily be incorporated in to the complete system package.Using the Trip Amplifier the system can be configured in two ways. Firstly, with alarm relay outputs for "loss of mains" and "low battery volts". The alternative gives a "low battery volts" alarm relay output and then also disconnects the battery when the voltage fails too low, to avoid permanent damage to the battery. >>>
View the product on rtkinstruments.com RTK Instruments Ltd
UPS CHLORIDE 80-NET

UPS CHLORIDE 80-NET

Transformer-less design for low weight, compact design and higher efficiency 80-NET is an entirely new transformer-less UPS offering unique IGBT rectifier and inverter employing double conversion technology. This architecture combines the secure power provided by double conversion with the efficiency provided by digital interactive technology. 80-NET can be fully adapted to meet diverse requirements in terms of battery backup time, power, redundancy and harmonic control. >>>
View the product on chloridepower.com Chloride Power Protection
POWERSOURCE 150 INVERTER - RINV150

POWERSOURCE 150 INVERTER - RINV150

PowerSource 150 Inverter Code: RINV150 The 12v 150w single socket PowerSource Inverter is simple and safe to use on equipment rated up to 150w such as televisions, DVD players, lighting, mobile phone chargers, electronic note pads, videos and computer consoles. Barcode: 5011274015084 Packaging: Boxed Euro Slot Pack Dimensions: 225 x 182 x 70 Product Dimensions: 143 x 92 x 60 Enlarge Image Specification Summary: Maximum power rating (watts) 150 Peak power (watts) 0.01 seconds 300 Stand by cutrrent (amps) >>>
View the product on ringautomotive.co.uk Ring Automotive Ltd.
MASTERGUARD SERIES C 10 - 60 KVA

MASTERGUARD SERIES C 10 - 60 KVA

Series C uses intelligent double conversion technology meaning users can select from the following operating modes: Double conversion: reducing network disturbances to a minimum. Digital interactive: allowing significant energy savings through high power efficiency. Separate bypass input terminals and top cable entry (on 50-60 kVA) provide maximum flexibility during installation. Special versions including full galvanic isolation transformer (400V/400V/50Hz, T version and 208V/208V/60Hz, LAM version) are available and are fully integrated into the UPS cabinet. Up to 8 three-phase Series C units can be connected in parallel. We are able to customise and adapt our solution as load requirements change. Applications Series C provides secure power infrastructure for a wide range of applications including: Storage Networks. Commercial Processing Systems. IT networks. Enterprise servers. Remote Monitoring The Series C family is fully compatible with LIFE.net, Masterguard's remote monitoring tool. This service provides: Automatic transmission of a daily status report. Continuous real time UPS monitoring and diagnosis. A remote fix capability. Regular UPS Operational status report supplied via post or email. Detailed operation history of the full service LIFE of the UPS system. ETS function for trouble-shooting of the most common operating anomalies. Power Quality Monitoring to effectively monitor power disturbance trends. >>>
View the product on masterguard.de MASTERGUARD Groupe - CHLORIDE POWER PROTECTION
SWITCH MODE POWER SUPPLY 24VDC - FLATPACK2 24/2000

SWITCH MODE POWER SUPPLY 24VDC - FLATPACK2 24/2000

Product Description The Flatpack2 is a battery charger and rectifier for stand-alone use or for working in parallel as part of a DC power system controlled and monitored by the Smartpack. Flatpack2 is optimized for a wide range of system sizes. Digital communication over CAN bus with Smartpack simplifies system design and enhances flexibility. Realization of Flatpack2 systems is possible by fitting 4 rectifiers across a 19” shelf. Applications Wireless, fiber and fixed line communication Today’s communications demand state of the art, cost efficient and compact DC power systems. Flatpack2 delivers the industry leading power density of 22W/in3 and superb reliability at lowest lifetime cost. Broadband and network access Increasing network speed demands flexible and expandable DC power solutions. Flatpack2 is your key building block for future needs. Key Features Highest efficiency in minimum space Resonant topology makes the module efficiency industry leading and contributes to the rectifier’s ultra compact dimensions. Digital controllers Primary and secondary controls are digitalized, enabling excellent monitoring and regulation characteristics. Thus, the number of component has been reduced by 40% - for highly reliable, long life, trouble free DC power systems. Heat management Front-to-back air flow with chassis-integrated heat sinks gives the module the most suitable working environment and no limitations in the scalability of the desired system solution. Unique connection A true plug-and-play connection system: time-to-install and cost-reducing solution. Global approvals Flatpack2 is CE marked, UL recognized and NEBS certified for world wide installation. Additional Technical Specifications AC Input Voltage 85-290 VAC (Nominal 176 – 275 VAC) Frequency 44 to 66Hz Maximum Current 13.4 Arms maximum at nominal input and full load Power Factor > 0.99 at 50% load or more Input Protection Varistors for transient protection Mains fuse in both lines Disconnect above 290 VAC DC Output Voltage 26.7 VDC (adj. range: 21.0-29.0 VDC) Output Power 2000 W at nominal input Maximum Current 84.0 Amps at 24 VDC and nominal input Current Sharing ±5% from true average current between modules Static voltage regulation ±0.5% from 10% to 100% load Dynamic voltage regulation ±5.0% for 10-90% or 90-10% load variation, regulation time < 50ms Hold up time > 20ms; output voltage > 21 VDC at 1000W load Ripple and Noise < 100 mV peak to peak < 0.96 mV rms psophometric Output Protection Overvoltage shutdown Blocking diode Short circuit proof High temperature protection Other Specifications Efficiency Typical 89% Isolation 3.0 KVAC – input and output 1.5 KVAC – input earth 0.5 KVDC – output earth Alarms: Warnings: Low mains shutdown High temperature shutdown Rectifier Failure Overvoltage shutdown on output Fan failure, one or two fans. Low voltage alarm at 21.5V CAN bus failure Rectifier in power derate mode Remote battery current limit activated Input voltage out of range, flashing at overvoltage Loss of CAN communication with control unit, stand alone mode Visual indications Green LED: ON, no faults Red LED: rectifier failure Yellow LED : rectifier warning Operating temp -40 to +75°C (-40 to +167°F) Storage temp -40 to +85°C (-40 to +185°F) Cooling 2 fans (front to back airflow) Fan Speed Temperature and load regulated MTBF > 200, 000 hours Telcordia SR-332 Issue I, method III (a) Acoustic Noise < 65dBA at nominal input and 70% load (Tambient < 30°C) Humidity Operating: 5% to 95% RH non-condensing Storage: 0% to 99% RH non-condensing Dimensions 109 x 41.5 x 327mm (wxhxd) (4.25 x 1.69 x 13”) Weight 1.9 kg (3.97 lbs) >>>
View the product on eltekvalere.com Eltek Valere
Go to page


  Search    
 
 
 
Search
See all of the sector's products : Electricity/Electronics