Acoustic measuring devices: suppliers, wholesalers and manufacturers on Hellopro
Search   


Acoustic measuring devices :

40 products
Select the category
Selection of 40 products among 40
ACOUSTIC MEASUREMENT : MI005

ACOUSTIC MEASUREMENT : MI005

The MI005 is a standardised (ISO 140) Tapping Machine designed to generate normalised impact noise for laboratory and field measurements of the impact sound insulation of floors. The MI005 has 5 hammers in line. Each hammer has a weight of 500 g and free-falls from a distance of 40 mm. The average time between impacts is 100 ms. 3 adjustable rubber feet support the unit in order to insulate the tapping machine from vibration. The MI005 can be operated with its own keyboard, but can also be remotely operated through a computer. The MI005 has overheating protection to avoid damage in case of abnormal operation, blockage or overload. The SF005 is a software application designed to control the MI005 from a computer. This remote control can be made via the supplied serial cable or through wireless connection using the BT001 BluetoothTM device. >>>
View the product on cesva.com CESVA
ACOUSTIC SENSORS FOR GRINDERS

ACOUSTIC SENSORS FOR GRINDERS

Using acoustic technology to detect subtle changes in the sounds produced during grinding, these systems produce extremely precise feed rate control when the wheel is touching the part or the dresser. Acoustic systems are particularly useful for preventing collisions and detecting machine and tool abnormalities, chipped grinding wheels and dresser faults. The acoustic sensor function can be easily implemented on any machine to improve cycle time and reduce costs. Integrated version into the in-process measurement and to the wheel balancing functions are available to further optimize the application. >>>
View the product on marposs.com Marposs
ENERGY ANALIZER - VIP396

ENERGY ANALIZER - VIP396

Description VIP 396 is a 96x96mm multifunctional panel meter, ideal for the measurement and display of electric parameters. The large clear LED displays showing parameters and values are easily read under all lighting conditions. The instrument displays up to 28 parameters (see table) and is suitable for installation on unbalanced threephase systems or twophase and singlephase systems. Supply and measurement connections are via sturdy 2.5 mm2 terminals and with 5A secondary CTs for current measurement. Technical specifications Maximum size (mm): instrument: 96 x 96 x 115.4 - Cut-out template: 91 x 91 Power supply: from network 230 V ~ or 115 V ~ ± 10% @ 35 - 400 Hz (4 VA) Display: Seven-segment 13 mm red LED’s, 3 digit on 3 lines Voltmeter inputs: VL1, VL2, VL3, N up to 350 V ~ phase-neutral, 600 V ~ phase-to-phase, 35÷400 Hz. Voltmeter input impedance: 2 M Voltage input overload: max 850 V ~ phase-neutral Amperometric inputs: AL1, AL2, AL3, COM. Consumption 1 VA. Three /5A external current transformer required Amper. input overload: max 7 A ~ permanent. 50A for 1 second. Number of scales: 1 voltage scale, 2 current scales Measurements: T.R.M.S. (true effective value) up to 24th harmonic (50 Hz), 20th (60 Hz) Precision: 1% reading per V and I; 2% for Power Suitable for connection to: Single phase or Three phase Star, Three phase Delta, or Diphase systems Weight: 0.6 Kg Protection level: instrument IP20, front panel IP30 Ambient temperature range: -10°C ÷ + 60°C Relative humidity range (R.H.): from 20% to 80%. Condensation not permitted. Models • Vip396: basic unit • Vip396 485: RS485 serial port, protocols: MODBUS ASCII, BCD and IEEE. • Vip396 485 4-20mA: RS485 serial port and 2 analog outputs 4-20mA or 0-20mA • Vip396 485 ALM: RS485 serial port and 2 relay outputs for alarms/pulses/relay • Vip396 LON FTT10: Lonworks protocol and FTT10 interface and relay output. For the LON model the exportable measurments are 22, to be chosen among the following: Threephase voltage Threephase current Threephase power factor Threephase active power Threephase reactive power Threephase apparent power Average active energy Average reactive energy Average apparent energy Active energy Reactive energy Frequency Voltage L1 Voltage L2 Voltage L3 Neutral current Current I1 Current I2 Current I3 Active power L1 Active power L2 Active power L3 Applications VIP 396 is a cost-efective instrument which can conveniently replace many traditional analog instruments in a very small space, simplifying wiring and with superior performances for both accuracy and reliability. Accuracy of measurements is guaranteed even for highly distorted waveforms, a critical issue for traditional instruments. >>>
View the product on elcontrol-energy.net ELCONTROL
CALIBRATION STANDARDS: OMNIDIRECTIONAL TRANSDUCER ITC-1089D

CALIBRATION STANDARDS: OMNIDIRECTIONAL TRANSDUCER ITC-1089D

ITC-1089D is a high frequency shperical unit covering frequencies up to 350 kHz. Encapsulated in high quality polyurethane and a depth capability of nearly 6,000 feet, it is also ideal for applications requiring small size. Specifications (Nominal) Type: Projector/Hydrophone Resonance Frequency fr: 280 kHz Depth: 2000 meters Envelope Dimensions (in.): .5D x 2.5L TVR at fr: 148 dB//?Pa/V@1m Midband OCV: -216 dB//1V/?Pa Suggested Band: .01 – 300 kHz Input Power: 20 watts >>>
View the product on itc-transducers.com International Transducer
BUDGET NOISE SYSTEM (GA213)

BUDGET NOISE SYSTEM (GA213)

The affordable risk assessment package for companies without a definite noise problem. * Easy to use sound meter * Simple calibration * Instant measurement at the touch of a button * Robust, easy to carry pocket size instruments This system performs the first stage of risk assessment to determine whether there is a noise problem requiring a full evaluation. Action level measurement gives a snapshot of the risk in your factory so you can act in confidence. >>>
View the product on castlegroup.co.uk/ Castle Group Ltd
ELECTRONIC PERSONAL DOSIMETERS IN CREDIT CARD SIZE DOSICARD - DOSIMAN

ELECTRONIC PERSONAL DOSIMETERS IN CREDIT CARD SIZE DOSICARD - DOSIMAN

Features Stand-alone electronic dosimeter with LCD display, large non volatile memory and programmable alarm levels on doses and dose rate Ultra thin/compact - light weight - shockproof - low cost Measures the X/g dose equivalent Hp(10) according to ICRU 39 Meets the latest regulations regarding the EMI compatibility - CE type approval Keystone of complete unique operational dosimetry systems Description With its credit-card size, DOSICARD features the smallest electronic dosimeter available on the market. It is also one of the most technologically advanced. It provides real time monitoring of the personal dose and dose rate. DOSICARD is the key element within a unique operational dosimetry system that can be tailored to your specific applications. DOSICARD addresses all workers exposed to a radiological risk in nuclear facilities, research and medical centers, and the nuclear industry. Therefore, it is of outstanding performance in the ALARA strategy of minimizing received doses. The DOSICARD badge is your radiation surveyor. It keeps you informed in real time of the radiation rate, allowing immediate reaction in case of radiation occurrence, thus drastically reducing the exposure to nuclear radiation. DOSICARD can also be part of a system: from nuclear laboratories of a few persons to nuclear facilities of several thousand workers, Dosemanager II and CARD Systems allow easy operation, and database management for efficient operational dosimetry monitoring. DOSICARD can display either Sv or rem, selection being made by the user in Dosemanager II. DOSIMAN can be delivered with either Sv or rem display (factory set). DOSICARD - Efficient and easy-to-use DOSICARD features a silicon detector, complete analog and digital circuitry, including a microcontroller with large non-volatile memory, a LCD display and audio and visual alarms. Three touch buttons allow programming and display setup of the current dose, dose rate and cumulative doses per day/month/quarter/year/five years. Non-volatile EEPROM memory safely stores the detailed history of the daily doses, times when alarm levels have been exceeded, as well as relevant data concerning the user and the badge itself. DOSICARD - Operational dosimeter Visual and audible alarms are generated as soon as a predefined threshold is exceeded on doses or dose rate. Only three buttons are necessary for daily use. Permanent or temporary display of current dose or dose rate values are available on the easy-to-read LCD screen. The direct access by the user to month/quarter/year/five year cumulative doses is protected by confidential password. DOSICARD - Compact and convenient Credit card format, 8 mm thick. Long battery life: typical 3000 hours. Transparent vinyl protective pocket with clip. Easy and low cost replacement in case of contamination. DOSICARD - Simple and powerful Two operating modes are provided: Permanent (continuous integration of doses) and Zone (integration of doses only within control zones, with operation controlled by entrance/exit badge readers). A large memory capacity enables storage of detailed dose history including: Dose accumulation modes: Daily: dose accumulated since midnight. Manual periodical: dose accumulated since manual start. Last 90 daily doses, last 60 monthly doses, month/quarter/year/five year cumulative doses. Such dose history can be accessed via a badge reader and is protected by a confidential password. Safe storage is guaranteed via a non-volatile EEPROM memory for 10 years without battery. DOSICARD - Multiple applications Monitoring personnel in controlled zones: nuclear research centers and laboratories, reprocessing plants, companies handling radioactive sources, etc. Dosimetry management in the biomedical domain (Nuclear Medicine, Cobaltotherapy, etc.). Individual survey in the vicinity of nuclear facilities, uranium mines, granitic grounds, high altitude sites, etc. Follow-up of aircraft crews. >>>
View the product on canberraeurisys.com Canberra Eurisys
INSPECTION SYSTEM SUPERSCAN

INSPECTION SYSTEM SUPERSCAN

The demand for the inspection of panel surfaces has increased due to the ever increasing production speeds and new process technologies. More and more is expected of humans as monitoring bodies. With laminate flooring being delivered almost directly to the end-user, hidden defects can lead to catastrophic consequences. Through the use of up-to-date image processing systems and completely new technology, it is very easy to monitor many different patterns with the GreCon Surface Inspection System SUPERSCAN. Typical surface inspection systems can barely differentiate between minor gradations of shades in the pattern, such as knots, and actual defects. This problem is eliminated with the newly developed system by GreCon. The SUPERSCAN system inspects each panel in the running production to ensure consistent sorting. Furthermore, fault and statistical reports allow adjustments to upstream production processes. Both the sorting and the entire production process can be optimized. >>>
View the product on grecon.de Grecon
ACOUSTIC EMISSION SENSOR - TYPE 8152B111

ACOUSTIC EMISSION SENSOR - TYPE 8152B111

Characteristics High Sensitivity and wide frequency range, inherent highpass characteristic, robust, suitable for industrial use (Degree of protection IP 65 resp. IP 67), ground isolated, CE compliant. Applications Measurment of very high frequency phenomena particularly on machine structures. Crack formation investigations, fatigue studies and machine tool diagnostics. >>>
View the product on kistler.fr Kistler
ENERGY ANALYZER - DMM3

ENERGY ANALYZER - DMM3

Description DMM3 is a 9 DIN modules multifunctional panel meter, ideal for the measurement and display of electric parameters. The large clear LED displays showing parameters and values are easily read under all lighting conditions. The instrument displays up to 28 parameters (see table) and is suitable for installation on unbalanced threephase systems or twophase and singlephase systems. Supply and measurement connections are via sturdy 2.5 mm2 terminals and with 5A secondary CTs for current measurement. Technical specifications Max dimensions (mm): instrument: 158.5 x 73 x 90. Power supply: from network 230 V~ or 115 V~ ± 10% @ 35 - 400 Hz (4 VA) Display: LED 7 segments 13 mm red, 3 x 3 numeric digits on 1 line. Voltmeter inputs: VL1, VL2, VL3, N up to 430 V~ phase-neutral, 600 V~ phase-phase, 35¸ 400 Hz. Voltmeter inputs impedance: 2 Mohm Voltmeter inputs overload: max 850 V~ phase-neutral Amperometric inputs: AL1, AL2, AL3, consumption 1 VA. Three external /5A curr. trasf. necessary Amperometric inputs overload: 7A permanent, 50A for 1 second. Number of scales: 1 voltage scale, 2 current scales Measurments: T.R.M.S. (true root mean square) up to the 25th harmonic (50 Hz), 20th (60Hz) Accuracy: 1% of reading for V and I; 1% for power Suitable for connection to: Singlephase or Threephase Star / Delta or Twophase systems Weight: 0.6 Kg Protection level: instrument IP20, front panel IP40 Ambient temperature range: -10°C ¸ + 60°C Relative humidity range: from 20% to 80%. Condensation: not permitted >>>
View the product on elcontrol-energy.net ELCONTROL
AUDIOMETRIC SCREENERS KAMPLEX KS5

AUDIOMETRIC SCREENERS KAMPLEX KS5

The KS5 is a pediatric free field audiometer for hand held operation. The light weight and the easy operation of the switches makes it ideal for easy behavioural testing of children's hearing. Stimuli may be pure tones from 500 Hz to 4kHz, or NB / WN all precisely calibrated. An optional TDH39 headphone may be connected and will have independent calibration to allow traditional screening with headphone. >>>
View the product on pcwerth.co.uk PC Werth Ltd
CONICAL BEAM: HIGH POWER DEPTH SOUNDER TRANSDUCER ITC-5008

CONICAL BEAM: HIGH POWER DEPTH SOUNDER TRANSDUCER ITC-5008

The ITC-5008 transducer is a direct replacement for the hull mounted UQN-1 type of depth sounder transducer for surface-ship applications. A broad, low frequency (12kHz) beamwidth is provided by one array of prestressed lead zirconate titanate elements. Exposed metal is a corrosion resistant nickel-aluminum bronze. Specifications (Nominal) Resonance Frequency fr: 12 kHz Depth: 100 meters Envelope Dimensions (in.): 16D x 8.9H TVR at fr: 163 dB//?Pa/V@1m Beam Width (-3dB) at fr: 30 deg Beam Type: Conical Input Power: 2000 watts >>>
View the product on itc-transducers.com International Transducer
CLASS 1 RISK ASSESSMENT/ENVIRONMENTAL SYSTEM

CLASS 1 RISK ASSESSMENT/ENVIRONMENTAL SYSTEM

The in-depth combination risk assessment package for larger applications. * Enhanced data analysis and manipulation * Portable and simple to use The meter is ideally equipped for carrying out Noise at Work Risk Assessments, as well as the majority of environmental survey work. The range of parameters measured, the wide measuring capability of the meter and the ease of use, mean that this equipment is suitable for anything from aircraft noise to lawnmower design, and from construction sites to laboratories. The Castle 6224 provides the essential measurements required by the Control of Noise at Work Regulations 2006, including Leq (equivalent continuous level) in ‘A’ and ‘C’ weightings, and Cpeak. The meter can data-log any of these parameters in up to 10,000 data-memories, making it more than powerful enough for the task in hand. >>>
View the product on castlegroup.co.uk/ Castle Group Ltd
DOSIMETER ANALYSER IN OCTAVE BANDS : DC112

DOSIMETER ANALYSER IN OCTAVE BANDS : DC112

The DC112 is a high performance dosimeter, the ideal instrument for measuring noise according to Directive 2003/10/CE, which adapts to technical progress the regulation on the health and safety requirements regarding the exposure of workers to the risks arising from noise. The DC112 enables you to measure simultaneously all the parameters needed to assess the levels of noise to which workers are exposed with and without hearing protectors (SNR, HML and Octaves). The DC112, besides measuring the equivalent level with A and C frequency weightings [ LAt, LCt ] (SNR and HML method), simultaneously carries out a real time frequency analysis with A frequency weighting and by octave bands from 63 Hz to 8 kHz (Octave method). The DC112 enables you to assess and measure exposure to noise and also brings you all the data needed to inform and train workers with regard to the significance and potential risks arising from the results of the measurement and assessment. Moreover, It helps you to design and run a reduction programme and to choose the most suitable hearing protectors. >>>
View the product on cesva.com CESVA
FLOOR LISTENER INSPECTION BY EDDY CURRENT

FLOOR LISTENER INSPECTION BY EDDY CURRENT

N. D. THREAD INSPECTION Thread inspection is a critical QC check in the industry and can be required after automated tapping operations. Through dedicated sensors the Eddy Current technology is able to determine thread condition vs no-thread condition. Working principle: When a sensor is inserted into tapped holes the Eddy Current induced in the surface will produce an analog voltage that is proportional to the radial distance. A wrong voltage signal will be an indication that holes were not correctly tapped. >>>
View the product on marposs.com Marposs
ENERGY ANALYZER - VIP96

ENERGY ANALYZER - VIP96

Description Vip 96 is a 96x96mm digital energy analyzer for panel mounting, suitable for monitoring and controlling industrial and civil loads. The instrument performs at the same time 7 measures displaying the values on a backlit LCD display. The measured parameters are: Volt (rms), AMP (rms), P.F., kW, kVAr, kVA, Hz. The instrument provides also active and apparent power peak values averaged on a 15 minutes integration time (versions with 10, 20 or 30 minutes integration times available). Technical specifications Inputs: Voltage: Singlephase (L1-N) max 750Vrms from 20 to 600Hz. Threephase (L1-N) max 750Vrms from 20 to 600 Hz. Current:: 5A from 20 to 600 Hz. Voltage inputs overload: Max 825 Vrms. Voltage peak 900Vrms Current input overload: 5 times Full Scale value (protection mechanism triggered by limit value) Number of scales: 3 voltage scales; 3 current scales. Automatic scale change: response time: 500ms. Change to upper scale occurs at 105% of the active scale. Change to lower scale occurs at 20% of the active scale. Dimensions: 96x96x130 mm. Weight: 1 Kg. Protection level: instrument IP20, front cover IP30. Test and operating conditions: Operating ambient conditions: temperature range: from -10‹C to +50‹C. Relative humidity range: from 20% to 80%. Storage temperature: from -20‹C to +60‹C. Condensation: not permitted Insulation resistance: 500 Mƒ¶ between input connectors and case Insulation voltage: between input connectors: tested at 2000Vrms 50Hz for 60 seconds. between input connectors and case: tested at 3000Vrms 50hZ for 60 seconds. Reference standards: IEC 348 class 1 for operating voltages lower than 650VACrms. VDE0110 group C for operating voltages below 500VACrms. Shock resistance: 10g Vibrations resistance: 10-55Hz (amplitude 0,5mm) Power supply: From network: 100€120/200€240V~10% Consumption: 3,5VA >>>
View the product on elcontrol-energy.net ELCONTROL
AUDIOMETRIC SCREENERS KAMPLEX KS8

AUDIOMETRIC SCREENERS KAMPLEX KS8

The KS8 is an inexpensive portable manual air conduction audiometer well suited for quick and efficient hearing evaluations in schools, industry, and other situations. The KS8 is fully portable and is easily carried in a briefcase or similar bag. A special lightweight carrying bag with shoulder strap is supplied as standard. This will hold the audiometer along with its accessories, including a noise reduction headset, that collectively weighs less than 2.0 kg (4.5 lbs.) >>>
View the product on pcwerth.co.uk PC Werth Ltd
HEMISPHERICAL BEAM: DEEP WATER DIRECTIONAL TRANSDUCER ITC-3013

HEMISPHERICAL BEAM: DEEP WATER DIRECTIONAL TRANSDUCER ITC-3013

The ITC-3013 is one of a family of versatile transducers that can be utilized in transponder, beacon and underwater communications systems. It is a low cost unit that offers highly efficient broadband transmission and reception with a hemispherical beam pattern. Specifications (Nominal) Resonance Frequency fr: 12.5 kHz Depth: Unlimited Envelope Dimensions (in.): 3.1D x 4.25H TVR at fr: 137 dB//?Pa/V@1m Beam Width (-3dB) at fr: 260 deg Beam Type: Hemispherical Input Power: 330 watts >>>
View the product on itc-transducers.com International Transducer
CLASS 2 RISK ASSESSMENT/ENVIRONMENTAL SYSTEM

CLASS 2 RISK ASSESSMENT/ENVIRONMENTAL SYSTEM

The in-depth combination risk assessment package for larger applications. * Enhanced data analysis and manipulation * Portable and simple to use The meter is ideally equipped for carrying out Noise at Work Risk Assessments, as well as the majority of environmental survey work. The range of parameters measured, the wide measuring capability of the meter and the ease of use, mean that this equipment is suitable for anything from aircraft noise to lawnmower design, and from construction sites to laboratories. The Castle 6226 provides the essential measurements required by the Control of Noise at Work Regulations 2006, including Leq (equivalent continuous level) in ‘A’ and ‘C’ weightings, and Cpeak. The meter can data-log any of these parameters in up to 10,000 data-memories, making it more than powerful enough for the task in hand. >>>
View the product on castlegroup.co.uk/ Castle Group Ltd
ENERGY ANALYZER - VIPENERGY

ENERGY ANALYZER - VIPENERGY

Description TOP PERFORMANCES IN A SMALL SPACE • 43 measures in 157,5mm DIN rail (9 DIN modules) Measurements on distorted and unbalanced systems. • Display with backlight • Easy to install and operate • All options can be programmed on the field • Signal outputs: versions with different configurations available for expanding the use of VIP ENERGY to industrial control applications. POWER MEASURES WHERE AND HOW YOU WANT THEM • WHERE: Installation on any modular panel • HOW: The measures provide a full view of electrical consumption and power peaks. COGENERATION PLANTS All models can be set to COG4 mode, which makes it possible to monitor energy consumption and generation on 4 quadrants. Technical specifications General Specifications Voltmeter Inputs: L1-N, L2-N, L3-N max 550 Vrms (STAR connection); L1-L3, L2-L3, L1-L2 max 550 Vrms (DELTA connection) from 20 to 600 Hz. Current Inputs: 5A from 20 to 600 Hz. Voltage Inputs overload: peak voltage 2000 Vrms (60 seconds). Current Inputs overload: 20 times the full scale value for 1 second (with overload cut-out triggered at limit values) Number of scales: 2 voltage scales; 3 current scales. Automatic scale change: response time 1,2 sec.; change to the upper scale occurs at 105% of the active scale; change to the lower scale occurs at 20% of the active scale. Dimensions: L. = 157.5 mm (9 DIN modules); H. = 90 mm; D. = 73 mm Lithium battery: 3 V; 200 mAh Weight: 1 kg. Protection level: instrument IP20; front panel IP40. • Stored measurement values are saved on a EEPROM (1.000.000 write min.) ensuring 40 years of data storage even with discharged battery. Service and testing conditions Ambient service conditions: temperature range: from -10°C to + 60°C; relative humidity range: from 20% to 80%. Storage temperature: from -20 to +70 °C. Condensation: not permitted. Insulation: VDE 0110 group C for operating voltage ­ 500 VAC rms. Insulation resistance: 500 Mohm between input terminals and outer casing. Insulation voltage between input connectors: testing at 2000 Vrms 50 Hz for 60" Insulation voltage between each input connector and casing: test at 3000 Vrms for 60 sec. Safety reference standards: IEC 348, VDE 411, class 1 for operating voltage­ 650 VAC rms; IEC 1010 550 V. EMC reference standards: EN 50081-1, EN 50082-2, EN 55011, EN 55022. >>>
View the product on elcontrol-energy.net ELCONTROL
PREAMPLIFIED: WIDEBAND PROBE HYDROPHONE ITC-6030

PREAMPLIFIED: WIDEBAND PROBE HYDROPHONE ITC-6030

The ITC-6030 wideband probe hydrophone is a small, lightweight, high sensitivity device with a frequency response extending beyond 100 kHz. Rather than a preamp adjacent to the transducer, the lTC-6030 employs a small buffer amplifier stage of unify gain allowing 50 or more feet of cable between the transducer and the preamplifier. The transducer and buffer stage are electrostatically shielded and molded in void-free polyurethane. Specifications (Nominal) Usable Frequency Range: 10Hz to 100 kHz Midband OCV: -192 dB//1V/?Pa Midband Beam Pattern Shape: Omnidirectional Depth: 900 meters >>>
View the product on itc-transducers.com International Transducer
NOISE GENERATOR INSTRUMENTS - ANG SERIES

NOISE GENERATOR INSTRUMENTS - ANG SERIES

ANG Series Precision Noise Generators: The ANG Series is the most flexible architecture available for automated noise generators. This rack mountable noise generator can be remote controlled via RS-232 or GPIB interfaces. A long list of options including; Input Signal Combiner, Monitoring Ports, and Noise Path Filtering give you the ability to design the ideal system for your application. >>>
View the product on micronetics.com Micronetics
ENERGY AND HARMONICS ANALYZER - VIP96PLUS

ENERGY AND HARMONICS ANALYZER - VIP96PLUS

Description VIP96 PLUS is a panel instrument providing all the information of the base model VIP96: Voltage (V rms), Current (A rms), P.F. CosØ, Active power (W), Reactive power (VAr), Apparent power (VA), Frequency (Hz), Active power peaks (W) e Apparent power peaks (VA) averaged over a set integration time. Additionally to all measures present on the base model, VIP96 PLUS offers many other functions providing more than 100 measures. •Average values for active power (W), reactive power (Var) and apparent power (VA), claculated over a set integration time. •Counters for active energy (kWh), reactive energy (kVArh) both in Standard Mode and Cogeneration Mode (positive and negative kWh counters, inductive and capacitive kVArh counters). •Total Harmonic Distortion Factor (THD) of voltage and current respective to fundamental and total rms value. •Voltage and current harmonics and CosØ value from the 1st to the 24th as absolute value and percentage of fundamental. •Crest Factor of voltage and current as absolute value and percentage. Such functions are very useful for a wide spectrum of applications including: •control and optimization of consumptions and loads; •analysis of harmonic distortion caused by non-linear loads; •prevention of the risk of resonance between power factor correction capacitor banks and transformers; •data acquisition on Personal Computer for the generation of graphic and numeric reports on the performance of installations and electrical machines. Technical specifications Power supply: from network 220 V ~ or 110 V ~ ± 10% - 50/60 Hz, consumption 4 VA Impedance of the voltmeter inputs: > 4 Mohm Voltmeter inputs: VL1-N up to 600 V ~ , up to 600 Hz. Current inputs: AL1 . Consumption … VA. from external CT …/5A Display: LCD with backlight Measures: T.R.M.S. (true effective value) Accuracy: 1% on voltage and current Dimensions: 96 x 96 x 130 mm Weight: 1 kg Protection level: instrument IP20, front panel IP30 Operative temperature range: -10°C ÷ + 50°C >>>
View the product on elcontrol-energy.net ELCONTROL
BEKESY AUDIOMETERS KC50 CLINICAL AUDIOMETER

BEKESY AUDIOMETERS KC50 CLINICAL AUDIOMETER

The KC50 is our full-featured state of the art audiometer. This audiometer features two independent channels that are configurable for either right or left hand operation. The KC50 is developed for the purpose of providing the advanced clinic or training institution with a tool that not only performs all traditional audiometric tests but also provides a full battery of classic supra threshold tests such as Bekesy, MLD, ABLB, and Loudness Scaling. >>>
View the product on pcwerth.co.uk PC Werth Ltd
SIDESCAN TRANSDUCER ITC-5202A

SIDESCAN TRANSDUCER ITC-5202A

The ITC-5202A is a full ocean rated sidescan transducer assembly. This unit has a very narrow beam and is shaded with low side lobes. It is suitable for most side scan or other high directivity needs. Specifications (Nominal) Resonance Frequency fr: 117 kHz Depth: Unlimited Envelope Dimensions (in.): 27L x 1.5W x 1.6H TVR at fr: 170 dB//?Pa/V@1m Beam Width (-3dB) at fr: 2.3 x 50 deg Input Power: 1500 watts >>>
View the product on itc-transducers.com International Transducer
MULTITARIFF ENERGY COUNTER - ED39DIN

MULTITARIFF ENERGY COUNTER - ED39DIN

Description ED39din 485 is a multi-functional instrument in a 9 DIN modules casing, ideal for the measurement and display of instant, average and maximum electrical consumption. ED39din can record active energy consumption on up to 4 tariff bands, selected via external digital signals. The 2 digital inputs can also be used as multipurpose pulse counters to count pulses from any kind of meter (gas, water, steam etc.). All data can be read via the RS485 serial line. ED39din is equipped with a LED display with large red digits that are easily read under any lighting condition and LEDs indicating the displayed parameters. The maximum number of displayed measures is 25 (see table). This instrument can be connected to unbalanced threephase , twophase and singlephase systems. Connections of supply and measurement cables are trough sturdy 2,5 mm2 terminals. Reading and programming are performed by use of the PAG key on the front panel and the SEL, SET keys. The setup menu can be password protected. ED39din 485 is a cost-effective instrument which can conveniently replace many traditional analog instruments in a very small space, simplifying wiring and with superior performances for both accuracy and reliability. Accuracy of measurements is guaranteed even for highly distorted waveforms, a critical issue for traditional instruments. Technical specifications Max dimensions (mm): instrument: 158.5 x 73 x 90. Power supply: from network 230 V~ or 115 V~ ± 10% @ 35 - 400 Hz (4 VA) Display: LED 7 segments 13 mm red, 3 x 3 numeric digits on 1 line. Voltmeter inputs: VL1, VL2, VL3, N up to 430 V~ phase-neutral, 600 V~ phase-phase, 35¸ 400 Hz. Voltmeter inputs impedance: 2 Mohm Voltmeter inputs overload: max 850 V~ phase-neutral Amperometric inputs: AL1, AL2, AL3, consumption 1 VA. Three external /5A curr. trasf. necessary Amperometric inputs overload: 7A permanent, 50A for 1 second. Number of scales: 1 voltage scale, 2 current scales Measurements: T.R.M.S. (true root mean square) up to the 25th harmonic (50 Hz), 20th (60Hz) Accuracy: 1% of reading for V and I; 1% for power Suitable for connection to: Singlephase or Threephase Star / Delta or Twophase systems Digital Inputs: 2 digital inputs to be connected to external voltage free contacts Max counting frequency: 25Hz minimum ON time = 20msec. Weight: 0.6 Kg Protection level: instrument IP20, front panel IP40 Ambient temperature range: -10°C ¸ + 60°C Relative humidity range: from 20% to 80%. Condensation: not permitted >>>
View the product on elcontrol-energy.net ELCONTROL
PANEL ENERGY ANALYSER  - STAR3DIN

PANEL ENERGY ANALYSER - STAR3DIN

Energy and armonics analyzer Description The STAR3 din is the latest instrument available from Elcontrol Energy Net. This high quality panel energy analyser provides brillant features at a price never reached before. The new bright LCD display, the harmonic analysis, the wide set of measured parameters including the TDH available in all the models, the multi-protocol capability of the RS485 port and the high accuracy class 0.5%, the 3 years warranty period, allow to consider the STAR3 the new state of art of the of the panel analysers market. It is a perfect, professional and low cost solution for the electrical panels, sub metering systems, OEM application The model with harmonics allows a permanent based control of one of the most important aspect of the power supply quality. Such important possibility, up to now, was reserved only to high-cost devices. The STAR3 din breaks this price barrier bringing, for the first time, the harmonic analysis into the market of the panel analysers. In addition to all usual measures, STAR3 din introduces many advanced features previously available only on high-cost devices. THD% provides a clear and immediate indication of a hidden problem: harmonic pollution. The neutral current indication gives information on the status of the neutral cable, which is often overloaded as a consequence of load unbalance and harmonics. The neutral current is a RMS value obtained with an intelligent calculation, which ensures a higher accuracy than direct measurement via a 4th CT. Technical specifications Maximum size (mm): instrument: 158.5 X 73 X 90. (9 DIN module) Power supply: from network 230 V ~ or 115 V ~ ± 15% -20% @ 35 ÷ 400 Hz (4VA) Display: LCD dispay, dot matrix Voltmeter inputs: VL1, VL2, VL3, N up to 430 V ~ phase-neutral, 600 V ~phase-to-phase, 35 ÷ 400Hz. Voltmeter input impedance: 2 M ohm Voltage input overload: max 850 V phase-neutral Amperometric inputs: AL1, AL2, AL3. Consumption 1 VA. Three external /5A curr. trasf. necessary. Amperometric inputs overload: 7A permanent, 50A for 1 second. Sensitivity : 20mA current ; 10V voltage Overcurrent : withstands 50A for 1 sec. Number of scales: 1 voltage scale, 2 current scales Measurements: T.R.M.S. (true effective value) up to 25 th harmonic = 1250 Hz with fundamental @50 Hz Accuracy: >>>
View the product on elcontrol-energy.net ELCONTROL
PANEL ENERGY ANALYSER - ENERGY MASTER

PANEL ENERGY ANALYSER - ENERGY MASTER

Memory module Description ENERGY MASTER is a device for panel or DIN-rail mounting. Thanks to an internal RS485 connection, Energy Master is able of independently reading and the storing the measurements of a network composed of a maximum of 128 Elcontrol Energy Net analysers. Through an Ethernet or RS232+modem connection, it is possible to communicate with ENERGY MASTER from a remote PC allowing: · To configure the device. · To detect automatically the instruments connected to the network. · To download the files related to measures and energy counters in three different ways: manually, programmed (day, hour) or automatically (due to the filling of the internal memory). · To set up alarm-thresholds and to receive alarm-messages upon their exceeding. · To manage the relays present on the instruments remotely. Energy Master is able to perform measurement campaigns on a weekly basis or setting a beginning/end dates. Technical specifications DIMENSIONS: 190X115X90 mm WEIGHT: 2Kg POWER SUPPLY: 100-240VAC 50/60Hz 30VA OPERATING SYSTEM: XP EMBEDDED COMMUNICATION PORTS: RS485,ETHERNET,RS232 (modem) MAXIMUM NUMBER OF INSTRUMENTS: 128 RS485 COMMUNICATION PROTOCOL: MODBUS RTU IEEE MINIMUM TIME BETWEEN TWO READINGS: 1 second MEMORY AVAILABLE: 200Mbyte MEMORY: Storing all available data: 10 Instruments, polling every 15' = 1,8 years 50 Instruments, polling every 15' = 4 months Storing only KWh, kvarh, KW, Kvar: 10 Instruments, polling every 1' = 2,7 years 50 Instruments, polling every 1' = 6 months POLLING MODES: “Continuous Type” with possibility to configure the intervals between the polling cycles “Campaign Type” with possibility to set up beginning/end dates or on weekly basis ALARM MESSAGES: 1 message of alarm for every instrument of the net controlled every cycle of polling (with continuous polling). 1 message of priority alarm for all instruments connected to the net checked every 2 or 4 seconds. LEVEL OF PROTECTION: IP20 OPERATING TEMPERATURE: From 0°C to 50°C PC SOFTWARE: PC Software to perform all the possible actions compatible with WINDOWS XP or WINDOWS NT. LANGUAGES: Italian, English, French, German, Spanish. EXTERNAL MODEM: Certified by ELCONTROL ENERGY >>>
View the product on elcontrol-energy.net ELCONTROL
PANEL ENERGY ANALYSER - STAR3

PANEL ENERGY ANALYSER - STAR3

Energy and harmonics analyzer Description STAR 3 is a high quality 96x96mm panel energy analyser provides brilliant features at a price never reached before. The new bright red LCD display, the harmonic analysis, the wide set of measured parameters including the THD available in all the models, the multi-protocol capability of the RS485 port and the high accuracy class 0.5%, the 3 years-warranty period, allow to consider the STAR 3 the new state of art of the panel analysers market. It is a perfect, professional and low cost solution for the electrical panels, sub-metering systems, OEM applications, supervisory systems, Building and Factory automation systems. The high flexibility of the instrument makes it adaptable to totally different applications. The models with harmonic analysis allows a permanent based control of one of the most important aspect of the power supply quality. Such important possibility, up to now, was reserved only to high-cost device. STAR 3 breaks this price barrier bringing, for the first time, the harmonic analysis into the market of the panel analysers. Technical specifications Maximum dimensions (mm): instrument: 96 X 96 X 115.4. Cut-out template: 91 X 91 Power supply: switching circuit from 90V to 230V ±15% AC/DC @ 35÷400 Hz (5 VA). Display: reverse red LCD with LED backlight Voltmeter inputs: VL1, VL2, VL3, N up to 350 V phase-neutral, 600 V phase-to-phase, 35÷400 Hz Voltmeter input impedance: 2 Mohm Voltage input overload: max 850 V phase-neutral Current inputs: AL1, AL2, AL3, COM., consumption 1 VA. Three or two 5A external curr.transf. required Measuring range: 0-120% In Sensitivity: current 20 mA ; voltage 10 mV Overcurrent: withstand 50 amps for 1 sec. Number of scales: 1 voltage scale, 2 current scales Measurements: True R.M.S. up to25th harmonic = 1250Hz with fundamental @50 Hz Sampling frequency: 2.5 kHz. Accuracy: >>>
View the product on elcontrol-energy.net ELCONTROL
KC50 CLINICAL AUDIOMETER

KC50 CLINICAL AUDIOMETER

The KC50 is our full-featured state of the art audiometer. This audiometer features two independent channels that are configurable for either right or left hand operation. The KC50 is developed for the purpose of providing the advanced clinic or training institution with a tool that not only performs all traditional audiometric tests but also provides a full battery of classic supra threshold tests such as Bekesy, MLD, ABLB, and Loudness Scaling. >>>
View the product on pcwerth.co.uk PC Werth Ltd




  Search    
 
 
 
Search
See all of the sector's products : Measuring devices, analysis and sensors