Acceleration sensors: suppliers, wholesalers and manufacturers on Hellopro
Search   


Acceleration sensors :

52 products
Select the category
Selection of 40 products among 52
DIGITAL LOAD CELL - BEAM - EX ATEX CERTIFIED - SDE

DIGITAL LOAD CELL - BEAM - EX ATEX CERTIFIED - SDE

Shockproof Digital Ex ATEX certified load cell type SDE The OIML certified beam load cells type SDE are used for general weighing in tough environments, in bench- and platform scales, belt scales and in production equipment. Features * ATEX (zone 1 and 2) approved with load cell module MCE3510 * Accuracy classes C1, C2, C3, C6 (MI10) to OIML R60 * High overload and sideload capacity 250 to 1.000 % of Rated Capacity * Uncomplicated mechanical installation without protecting devices * Patented high reliability sensor * Stainless steel, laser welded to IP68 * Uncomplicated electrical installation - coaxial cable only * Output RS485/422, RS232, Profibus DP, DeviceNet, Modbus, 4-20 mA, 0-10 V to PLCs, PCs etc. and OIML certified weighing displays * Withstands welding voltages and ESD to IEC 1000-4-4 * ATEX approved version available (type SDE) Technology The Eilersen shockproof digital load cells are based on a patented capacitive measurement principle where a non-contacting capacitive sensor is mounted inside the load cell body. As the capacitive sensor is not in contact with the load cell body, the load cells are to a very high degree unaffected by overloads, sideloads, shocks and welding voltages. Therefore, the straightforward mechanical installation of the load cells can be done without expensive and complicated mounting kits and overload protection devices. The electrical installation of the digital load cells is pure plug-and-play as the signal from the non-contacting capacitive sensor is directly converted, compensated and calibrated by a patented ASIC to a digital output in grams, kilograms, tons or Newton. This digital signal is transmitted as RS485 data on a low-cost RG-58 single wire coaxial cable which may be up to 100 meters long. The calibration of the digital load cells is independent of the load cell cable length. Furthermore, the Eilersen digital load cells feature integrated diagnostics. Specifications Capacities 1, 2, 5, 10, 20, 50, 100, 200, 500, 1000kg. Overload, Sideload safe 1000% at 1kg, 200 % at 1000 kg capacity Non-Repeatability 0.005% max Hysteresis 0.01% max Combined error SDE industrial 0.10% max, SDE-high precision 0.015% max Creep Error 0.015% max in 30 min. Temperature range -20 to 40 degr. Celsius Compensated temperature range -10 to 40 degr. Celsius Temperature effect on Zero/Range SDE industrial 20 ppm/ degr. Celsius, SDE high precision 7 ppm/ degr.Celsius Cable 6m standard RG58 with BNC connector Weight 2300 g Materials AISI 316 and 17-4 PH >>>
View the product on eilersen.com Eilersen Electric
ACCELEROMETER : AC006

ACCELEROMETER : AC006

The AC006 is high sensitivity piezoelectric accelerometer. The main feature of its use in the measurement of human exposure to different kinds of vibration is its excellent response to low frequencies. It is designed with a piezoelectric crystal in shear mode, virtually eliminating base strain, thermal transients and other phenomena that are accentuated at low frequencies. Because it is an active transducer, the AC006 requires a constant current source to power the internal circuitry which gives it low internal impedance. >>>
View the product on cesva.com CESVA
DIGITAL LOAD CELL - BEAM - SD

DIGITAL LOAD CELL - BEAM - SD

Specifications -------------------------------------------------------------------------------- Shockproof Digital load cell type SD The OIML certified beam load cells SD are used for general weighing in tough environments, in bench- and platform scales, belt scales and in production equipment. Features * Accuracy classes C1, C2, C3, C6 (MI10) to OIML R60 * High overload and sideload capacity 250 to 1.000 % of Rated Capacity * Uncomplicated mechanical installation without protecting devices * Patented high reliability sensor * Stainless steel, laser welded to IP68 * Uncomplicated electrical installation - coaxial cable only * Output RS485/422, RS232, Profibus DP, DeviceNet, Modbus, 4-20 mA, 0-10 V to PLCs, PCs etc. and OIML certified weighing displays * Withstands welding voltages and ESD to IEC 1000-4-4 * ATEX approved version available (type SDE) Technology The Eilersen shockproof digital load cells are based on a patented capacitive measurement principle where a non-contacting capacitive sensor is mounted inside the load cell body. As the capacitive sensor is not in contact with the load cell body, the load cells are to a very high degree unaffected by overloads, sideloads, shocks and welding voltages. Therefore, the straightforward mechanical installation of the load cells can be done without expensive and complicated mounting kits and overload protection devices. The electrical installation of the digital load cells is pure plug-and-play as the signal from the non-contacting capacitive sensor is directly converted, compensated and calibrated by a patented ASIC to a digital output in grams, kilograms, tons or Newton. This digital signal is transmitted as RS485 data on a low-cost RG-58 single wire coaxial cable which may be up to 100 meters long. The calibration of the digital load cells is independent of the load cell cable length. Furthermore, the Eilersen digital load cells feature integrated diagnostics. Specifications Capacities 1, 2, 5, 10, 20, 50, 100, 200, 500, 1000kg. Overload, Sideload safe 1000% at 1kg, 200 % at 1000 kg capacity Non-Repeatability 0.005% max Hysteresis 0.01% max Combined error SD industrial 0.10% max, SD-high precision 0.015% max Creep Error 0.015% max in 30 min. Temperature range -50 to 90 degr. Celsius Compensated temperature range -10 to 50 degr. Celsius Temperature effect on Zero/Range SD industrial 20 ppm/ degr. Celsius, SD high precision 7 ppm/ degr.Celsius Cable 6m standard RG58 with BNC connector Weight 2300 g Materials AISI 316 and 17-4 PH >>>
View the product on eilersen.com Eilersen Electric
ACCELEROMETERS - HF SERIES

ACCELEROMETERS - HF SERIES

Low Noise, Wide Bandwidth Easy to Use High Frequency Vibration Sensor ±10 g and ±100 g Ranges The HF Series accelerometers are precision vibration sensors based on an advanced piezoelectric material integrated with signal conditioning (charge amp) and current regulation electronics. The sensor features low noise, 300 ?grms, and wide bandwidth, 0.3 - 10,000 Hz. Unlike the other Crossbow accelerometer series, the HF Series does not have a DC response, which means the unit will not respond to gravity or other very low frequency ( >>>
View the product on xbow.com Crossbow
DIGITAL LOAD CELL - COMPRESSION - EX ATEX CERTIFIED - MDEE

DIGITAL LOAD CELL - COMPRESSION - EX ATEX CERTIFIED - MDEE

Specifications -------------------------------------------------------------------------------- Shockproof Digital Ex ATEX certified load cells type MDEE Features * Ex ATEX certified with load cell module MCE3510 * High overload and sideload capacity 200 to 1000 % of rated capacity * Uncomplicated mechanical installation without protecting devices * Patented high reliability capacitive sensor * Stainless steel, laser welded to IP68 * Uncomplicated electrical installation - coaxial cable only * Output RS485/422, RS232, Profibus DP, DeviceNet, Modbus, 4-20 mA, 0-10 V to PLCs, PCs etc. * 32 bit data word does away with dead weight compensation * Withstands welding voltages and ESD to IEC 1000-4-4 Technology The Eilersen shockproof digital load cells are based on a patented capacitive measurement principle where a non-contacting capacitive sensor is mounted inside the load cell body. As the capacitive sensor is not in contact with the load cell body, the load cells are to a very high degree unaffected by overloads, sideloads, shocks and welding voltages. Therefore, the straightforward mechanical installation of the load cells can be done without expensive and complicated mounting kits and overload protection devices. The electrical installation of the digital load cells is pure plug-and-play as the signal from the non-contacting capacitive sensor is directly converted, compensated and calibrated by a patented ASIC to a digital output in grams, kilograms, tons or Newton. This digital signal is transmitted as RS485 data on a low-cost RG-58 single wire coaxial cable which may be up to 100 meters long. The calibration of the digital load cells is independent of the load cell cable length. Furthermore, the Eilersen digital load cells feature integrated diagnostics. Specifications Capacities 20, 50, 100, 150, 250, 500, 1000, 1500kg, 2t, 3t, 4t, 5t. Overload, Sideload safe 1000% at 20 kg, 200 % at 5t capacity Non-Repeatability 0.01% max Hysteresis 0.02% max Combined error MDEE industrial 0.10% max, MDEE high precision 0.025% max Creep Error 0.02% in 30 min. Temperature range -20 to 40 degr. Celsius Compensated temperature range -10 to 40 degr. Celsius Temperature effect on Zero/Range MDEE industrial 20 ppm/ degr. Celsius, MDEE high precision 7 ppm/ degr.Celsius Cable 6m standard RG58 with BNC connector Weight 1800 g Materials AISI 316 and 17-4 PH >>>
View the product on eilersen.com Eilersen Electric
DIGITAL LOAD CELL - COMPRESSION - FD

DIGITAL LOAD CELL - COMPRESSION - FD

Specifications -------------------------------------------------------------------------------- Shockproof Digital load cells type FD Features * High overload and sideload capacity 200 to 400 % of rated capacity * Uncomplicated mechanical installation without protecting devices * Patented high reliability capacitive sensor * Stainless steel, laser welded to IP68 * Uncomplicated electrical installation - coaxial cable only * Output RS485/422, RS232, Profibus DP, DeviceNet, Modbus, 4-20 mA, 0-10 V to PLCs, PCs etc. * 32 bit data word does away with dead weight compensation * Withstands welding voltages and ESD to IEC 1000-4-4 * ATEX certified version available (type FDEE) Technology The Eilersen shockproof digital load cells are based on a patented capacitive measurement principle where a non-contacting capacitive sensor is mounted inside the load cell body. As the capacitive sensor is not in contact with the load cell body, the load cells are to a very high degree unaffected by overloads, sideloads, shocks and welding voltages. Therefore, the straightforward mechanical installation of the load cells can be done without expensive and complicated mounting kits and overload protection devices. The electrical installation of the digital load cells is pure plug-and-play as the signal from the non-contacting capacitive sensor is directly converted, compensated and calibrated by a patented ASIC to a digital output in grams, kilograms, tons or Newton. This digital signal is transmitted as RS485 data on a low-cost RG-58 single wire coaxial cable which may be up to 100 meters long. The calibration of the digital load cells is independent of the load cell cable length. Furthermore, the Eilersen digital load cells feature integrated diagnostics. Specifications Type Unit Value Rated capacity (Emax) Kg 6.000, 8.000, 10.000, 15.000, 20.000, 25.000, 50.000 Ratio of min dead load output return Z 5.000 Total error (accuracy) % of Emax 0,05 or 0,03 Non-Repeatability % < 0,01 Hysteresis % < 0,02 Creep Error % in 30 min. < 0,02 Compensated temperature range °Celcius -10 to 55 Operating temperature range °Celcius -50 to 90 Temperature effect on Zero/Range ppm/°Celsius 20 Safe overload limit (Lim) % of Emax 300 to 1.000 Deflection at Emax mm < 0,1 Measuring rate Per second 200 Excitation voltage Vdc 24 +/- 20% Material AISI 316 and 17-4 PH Protection IP 68 Cable 6 meter standard coaxial RG58 with BNC connector Weight Kg 7.0 Interfaces Displays, Profibus, DeviceNet, CAN, Modbus, RS232, RS485, 4-20 mA, 0-10 V Baud rate Baud 115/230 kB Max. number of bus members 16 Guarantee 3 years >>>
View the product on eilersen.com Eilersen Electric
DIGITAL LOAD CELL - COMPRESSION - MD

DIGITAL LOAD CELL - COMPRESSION - MD

Specifications -------------------------------------------------------------------------------- Shockproof Digital load cells type MD Features * High overload and sideload capacity 200 to 1000 % of rated capacity * Uncomplicated mechanical installation without protecting devices * Patented high reliability capacitive sensor * Stainless steel, laser welded to IP68 * Uncomplicated electrical installation - coaxial cable only * Output RS485/422, RS232, Profibus DP, DeviceNet, Modbus, 4-20 mA, 0-10 V to PLCs, PCs etc. * 32 bit data word does away with dead weight compensation * Withstands welding voltages and ESD to IEC 1000-4-4 * ATEX certified version available (type MDEE) Technology The Eilersen shockproof digital load cells are based on a patented capacitive measurement principle where a non-contacting capacitive sensor is mounted inside the load cell body. As the capacitive sensor is not in contact with the load cell body, the load cells are to a very high degree unaffected by overloads, sideloads, shocks and welding voltages. Therefore, the straightforward mechanical installation of the load cells can be done without expensive and complicated mounting kits and overload protection devices. The electrical installation of the digital load cells is pure plug-and-play as the signal from the non-contacting capacitive sensor is directly converted, compensated and calibrated by a patented ASIC to a digital output in grams, kilograms, tons or Newton. This digital signal is transmitted as RS485 data on a low-cost RG-58 single wire coaxial cable which may be up to 100 meters long. The calibration of the digital load cells is independent of the load cell cable length. Furthermore, the Eilersen digital load cells feature integrated diagnostics. Specifications Type Unit Value Rated capacity (Emax) Kg 20, 50, 100, 150, 250, 500, 1.000, 1.500, 2.000, 3.000, 4.000, 5.000 Ratio of min dead load output return Z 5.000 Total error (accuracy) % of Emax 0,10, 0,05 or 0,025 Non-Repeatability % < 0,01 Hysteresis % < 0,02 Creep Error % in 30 min. < 0,02 Compensated temperature range °Celcius -10 to 55 Operating temperature range °Celcius -50 to 90 Temperature effect on Zero/Range ppm/°Celsius 20 Safe overload limit (Lim) % of Emax 300 to 1.000 Deflection at Emax mm < 0,10 Measuring rate Per second 200 Excitation voltage Vdc 24 +/- 20% Material AISI 316 and 17-4 PH Protection IP68 Cable 6 meter standard coaxial RG-58 with BNC connector Weight Kg 2.1 Interfaces Displays, Profibus, DeviceNet, Modbus, RS232, RS485/422, 4-20 mA, 0-10 V Baud rate Baud 115/230 kB Max. number of bus members 16 Guarantee 3 years >>>
View the product on eilersen.com Eilersen Electric
ACCELEROMETER SIMULATOR - HS-661

ACCELEROMETER SIMULATOR - HS-661

The HS-661 Accelerometer Simulator is a battery powered, hand-held unit designed to enable installation engineers to test vibration monitoring systems that emply 100mV/g constant current type accelerometers. The unit provides two switched levels of simulated vibration velocity signals, 5mm/s and 20mm/s, allowing verification of vibration monitor and alarm circuits. The switched vibration levels, and accelerometer power from the monitoring system, are indicated by LEDs. >>>
View the product on hansfordsensors.com Hansford Sensors Ltd.
DIGITAL LOAD CELL - HEAVY DUTY BEAM - SDM70

DIGITAL LOAD CELL - HEAVY DUTY BEAM - SDM70

Specifications -------------------------------------------------------------------------------- Shockproof Digital Heavy Duty Beam Load Cells type SDM70 The OIML certified (C3 and C5) beam load cells type SDM70 are used for general weighing in though environments such as on-board truck weighing, offshore, and weigh-in-motion applications. ATEX certified version available (type SDCE). Features * Accuracy classes C1, C2, C3, C5 to OIML R60 * High overload and sideload capacity 250 to 1.000 % of Rated Capacity * Uncomplicated mechanical installation without protecting devices * Patented high reliability sensor * Stainless steel, laser welded to IP68 * Uncomplicated electrical installation - coaxial cable only * Output RS485/422, RS232, Profibus DP, DeviceNet, Modbus, 4-20 mA, 0-10 V to PLCs, PCs etc. and OIML certified weighing displays * Withstands welding voltages and ESD to IEC 1000-4-4 * ATEX approved version available (type SDCE) Technology The Eilersen shockproof digital load cells are based on a patented capacitive measurement principle where a non-contacting capacitive sensor is mounted inside the load cell body. As the capacitive sensor is not in contact with the load cell body, the load cells are to a very high degree unaffected by overloads, sideloads, shocks and welding voltages. Therefore, the straightforward mechanical installation of the load cells can be done without expensive and complicated mounting kits and overload protection devices. The electrical installation of the digital load cells is pure plug-and-play as the signal from the non-contacting capacitive sensor is directly converted, compensated and calibrated by a patented ASIC to a digital output in grams, kilograms, tons or Newton. This digital signal is transmitted as RS485 data on a low-cost RG-58 single wire coaxial cable which may be up to 100 meters long. The calibration of the digital load cells is independent of the load cell cable length. Furthermore, the Eilersen digital load cells feature integrated diagnostics. Specifications Capacities 1, 2, 3 tons Overload, Sideload safe up to 1000% Non-Repeatability 0.01% max Hysteresis 0.02% max Combined error Industrial 0.1% max, A high precision 0.02% max Creep Error 0.02% max in 30 min. Temperature range -50 to 90 degr. Celsius Compensated temperature range -10 to 50 degr. Celsius Temperature effect on Zero/Range SDM industrial 20 ppm/ degr. Celsius, SDM high precision 7 ppm/ degr.Celsius Cable 6m standard RG58 with BNC connector Weight 10.1 kg Materials AISI 316 and 17-4 PH >>>
View the product on eilersen.com Eilersen Electric
PIEZORESISTIVE ACCELEROMETER MODEL 7270A

PIEZORESISTIVE ACCELEROMETER MODEL 7270A

The Model 7270A series of piezoresistive accelerometers are rugged un-damped units designed for shock measurements. ENDEVCO micro-machines the sensing system of the 7270A from a single piece of silicon. This etched silicon chip includes the inertial mass and strain gages arranged in an active four-arm Wheatstone bridge circuit complete with a novel on chip zero balance network. >>>
View the product on endevco.com Endevco




  Search    
 
 
 
Search
See all of the sector's products : Measuring devices, analysis and sensors